Manufacturing and Sales: Cables, Wires, Wires Drawing
产品Price Negotiable
最小起订Quantity:1 Rice 供货总Quantity: 9999 Rice
Product Features: |
|
Import Status: |
No |
Core Material: |
Copper wire |
MYP Mining Cable Specifications | MYP Mining Cable Application Range Detailed Description Mobile Cable for Coal Mines: MYP Cable, MY Cable, MYP 0.66/1.14KV Sheathed Cable, MYP 0.38/0.66KV Cable, MY 0.38/0.66 Cable Rated Voltage 0.66/1.14KV and Mining Mobile Rubber Sheathed Flexible Cables (GB12972.5-91) This product is suitable for copper-core rubber sheathed flexible cables used in mobile equipment rated at 0.66/1.14KV and below. Model Name Main Application UY-0.38/0.66 Mining Mobile Rubber Sheathed Flexible Cable, rated voltage 0.38/0.66KV for power connections to various underground mobile coal mining equipment (MYP) UYP-0.38/0.66 Mining Mobile Shielded Rubber Sheathed Flexible Cable, rated voltage of 0.38/0.66KV for power connections to various underground mobile coal mining equipment (MYP) UYP-0.66/1.14 Mining Mobile Shielded Rubber Sheathed Cable, rated voltage 0.66/1.14KV for power connections to various underground mobile coal mining equipment Nominal Cross Section (mm²) Power Core UC-0.38/0.66 UCP-0.38/0.66 Power Wire Core Ground Wire Core Insulation Nominal Thickness (mm) Min. Max. Min. Max. UC UCP 3×4 1×4 1.4 3.5 20.3 23.4 23.7 27.2 670 785 3×6 1×6 1.4 3.5 23 26.4 26.4 30.1 838 927 3×10 1×10 1.6 4 27.5 31.3 30.9 34.7 1292 1400 3×16 1×10 1.6 4 29.6 33.4 33 36.8 1465 1586 3×25 1×16 1.8 4.5 35.6 39.8 39 43.2 2159 2296 3×35 1×16 1.8 4.5 38.7 42.1 42.1 46.3 2596 2783 3×50 1×16 2 5 43.6 47.1 47.1 51.4 3385 3548 3×70 1×25 2 5 49.7 54.4 52.4 57.1 4292 4477 MYP Mining Cable Specifications | Application Range of MYP Mining Cable Number of cores x conductor Cable outer diameter Cable reference weight (kg/km) Nominal Cross Section (mm²) Power Core Sheath Nominal UC-0.38/0.66 Power Wire Core, Ground Wire Core, Insulation Nominal Thickness (mm), Thickness (mm), Minimum Value, Maximum Value 3×10 1×10 1.8 4.5 32.4 36.2 1476 3×16 1×10 1.8 4.5 34.6 38.4 1737 3×25 1×16 2 5 41.4 45.3 2400 3×35 1×16 2 5 44.2 48.4 2857 ×350 1×16 2.2 5.5 49.1 53.4 3549 3×70 1×25 2.2 5.5 55.5 60.2 4608 3×95 1×25 2.4 6 61.2 65.9 4608 Insulation resistance between the main cores of the cable and between the main cores and the ground wire, converted to +20°C, should not be less than 100MΩ·km. 2. The transition resistance of the main core shielding layer is not higher than 3kΩ when converted to 20°C. MYP Mining Cable Specifications | Application Range of MYP Mining Cable
Core Number × Conductor Sheath Nominal Thickness (mm) Cable Outer Diameter Cable Reference Weight (kg/km)




Phone Consultation