LSD50/200CType Solid-State Decoupler

I. Overview

As the use of cathodic protection technology for buried steel pipelines becomes more widespread, the stability of the cathodic protection systems is also a major concern. However, in real production and daily life, electromagnetic interference is omnipresent, and its impact on the cathodic protection systems for pipelines is also significant. Instances of electromagnetic interference causing the failure of cathodic protection functions, accelerating corrosion, and damaging impressed current equipment are not uncommon. Therefore, addressing interference issues has become one of the crucial problems in cathodic protection systems. The commonly adopted method to solve electromagnetic interference is to install drainage devices on the pipeline, which can effectively resolve the interference and maintain the pipeline potential at a reliable level. Nevertheless, existing drainage devices also have certain limitations, such as their inability to withstand strong energy disturbances like direct lightning currents and induced lightning currents.Solid-state decouplers effectively address fault grounding short-circuit currents in high-voltage lines, grounding currents introduced from lightning strikes on overhead transmission lines, and stray currents generated when trains pass over railway tracks. This product protects against overvoltage or overcurrent caused by the aforementioned situations, preventing pipeline cathodic protection from being affected and safeguarding against increased corrosion due to electromagnetic interference, providing effective protection for pipeline equipment.

Section II: Reference Standards

IEC61643.1-2005Surge Protectors for Low-Voltage Power Distribution Systems No Chinese content provided.1"Performance Requirements and Testing Methods"

NACE RP0177"Measures to Mitigate the Impact of Alternating Current and Lightning on Metal Structures and Corrosion Control Systems"
GB18802.1-2002/IEC61643-1
Surge Protectors for Low-Voltage Distribution SystemsSPD) 1st1"Performance Requirements and Testing Methods"

GB/T19271.1"Part of Protection against Lightning and Electromagnetic Pulses: General Rules"

GB50057"Code for Lightning Protection Design of Buildings"

GB50251"Regulations for Gas Pipeline Engineering Design"

GB50253"Design Specifications for Oil Pipeline Engineering"

GB4208IP Rating Protection ClassIPNo Chinese content provided.
GB/T2423
"Environmental Testing for Electrical and Electronic Products"
SY/T0032-2000 
"Underground Steel Pipe Exchange and Drainage Protection Technical Standard"

 

 

 

Section Three: Decoupler Dimensional Drawing


Four: Performance Parameters

Serial Number

Project

Technical Specifications

1

Direct Current Starting Voltage(1mA)

-2.0V/+2.0V

2

AC/DC Current Drain Rated Value

45A

3

Rated Discharge Current

100kA8/20μs

4

High-discharge current

200kA8/20μs

5

Leakage Current

10μA

6

Communication Impedance

<0.01Ω

7

Breakthrough Conduction Voltage

2200V1.2/50μs

8

Fault Current

AC-rms/Industrial Frequency/30Zhou Bo≥3500A

9

Response Time

1ns

10

Operating Temperature

-45+60

V. Technical Specifications

Installation Type and Location

Buried/Surface

Chassis Dimensions

200×300×150mm

Bracket dimensions

Φ90×2200   mm

Explosion-Proof Type

Body explosion-proof

Shell Protection Grade

IP65

Shell Material

Cast Aluminum

Coating Protection

Powder Coating

Internal Structure Three-Proof

Moisture-proof, salt fog-proof, and anti-bacterial

 

Internal high current connection cable

AGG-10kVSilicone High-Voltage Cable

Voltage Grade

10kV

Insulation coating

Insulation Resistance ≥100MΩ

Single-core multi-strand copper conductors

25mm²

 

 

 

Section 6: Installation Dimensions

                              

Seven: Contact Methods

Section 8: Installation Instructions

1Attach one end of the product to the pipeline and the other end to the grounding grid. The grounding resistance value of the grounding grid should be controlled at4Within Ohm.

2This product can be equipped with an explosion-proof box structure and installed directly in an explosion-proof environment.

3This product features a sealed structure, making it suitable for installation in humid environments.

 

Nine: Maintain

This product is maintenance-free; however, an increase in direct lightning strikes or other high-current impacts (exceeding)15(Paragraph), there is a possibility of product deterioration, which means the product may be damaged and cease to function. The product should be regularly opened to check the resistance at both ends of the product's wiring terminals. If the resistance is at the ohm level, the product should be promptly repaired or replaced.