FEBUS A1-R Distributed Fiber Optic Acoustic Sensing System_SupplyPro Co., Ltd._Beijing Tongwei Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Beijing Tongwei Technology Co., Ltd.

Technical promotion services; rental of construction machinery and equipment;...

Consultation Hotline
13810170854  15801056960

Product Categories
Home > SupplyPro Co., Ltd. > FEBUS A1-R Distributed Fiber Optic Acoustic Sensing System
FEBUS A1-R Distributed Fiber Optic Acoustic Sensing System
品牌: Tongwei
Body Noise: 10 pico strain
Measure Distance: 50 km
Spatial Resolution (Measurement Length): 1 m to 50 m
单价: 2480000.00/Piece
最小起订Quantity: 1 Piece
供货总Quantity: 100 Piece
有效期至: 长期有效
最后更新: 2021-09-13 11:48
 
详细Info

FEBUS A1-R | Distributed Fiber-Optic Acoustic Sensing System

Distributed Fiber-Optic Acoustic Sensing Equipment


Vibration Monitoring

Single-end measurement

Phase and Amplitude Monitoring

Easy to install and use

A choice under stringent conditions

As needed, software and interface development.


Advantages Overview

The FEBUS A1-R Distributed Fiber Optic Acoustic Sensing System provides acoustic information at intervals of every 2 meters (typical value) along the kilometers of fiber optic infrastructure deployed. The FEBUS A1-R equipment can also be directly connected to existing fiber optic cables. It only requires that the fiber be single-mode. This system is specially designed and developed, particularly suitable for harsh environments and one-end measurement requirements. Additionally, we offer personalized customization services for the FEBUS A1-R.

Site Inspection

Fiber Deployment (via experienced partners)

• Customized analysis modules and user interfaces as per requirement

• For use with SCADA or similar systems

• 2-year warranty and optional maintenance plans

Wide application range

The FEBUS A1-R Distributed Optical Acoustic Sensing System is an ideal device for many infrastructure monitoring applications, such as:

Pipe, riser, and oil outlet leakage monitoring

Oil Well Safety (Fracture Monitoring, Flow Monitoring)

Vertical Seismic Analysis

Perimeter Security (Intrusion Detection)

Railway Track/Railway Locomotive Safety Monitoring

Undersea Cables (Impact Testing, Electrical Partial Discharge)


Features and Performance Parameters

Performance Parameters

Type

Phase (Quantitative Acoustic Sensing)

Self-noise

10 pico strain(Slight Adaptation)

Measure Distance

50 km

Spatial resolution (measurement length)

1 m to 50 m

Sample interval

0.4 m to 50 m

Detection Frequency

50 kHz at 1 km Cable Length

2.5 kHz at 20 kmFiber Optic Cable Length

1 kHz at 50 kmFiber optic cable length

< 0.1 Hz Reliable (Micro-Vibration)

Optical Properties

Sensor Configuration

Single-endConnect only one end of the fiber, no specific terminal module required.

Fiber Optic Requirements

Single-mode Fiber Optic Cable

Fiber optic interface

E2000/APC

Technical Data

Operating System

Linux (CentOS based)

Communication Interface

Ethernet

Data storage space

Multiple1 TBOption: External20 TB RAID10Data Storage

Data Transmission Protocol

MODBUS, FTP, interoperability with other parties SCADA interoperability with other parties SCADA

Display

HDMI, DVI

External Interface

USB x6

Power Consumption

500 W

Size

19 ” / 4 U

Weight

15 kg

Environmental Conditions

Operating Temperature Range

5 °C to +40 °C, 80 RH

-40 °C to + 40 °C (Option: ET Version)

Storage temperature range

-10 °C to +60 °C

询价单
 Click submit means you agree to《Service terms》《Privacy policy》

15801056960