Explosion-proof modular air conditioning units - Product Features
1. Explosion-proof performance
Utilizing explosion-proof technology for enhanced safety and reliability; explosion-proof markings: ExdibmbllBT4 Gb, ExdibmbllCT4 Gb.
2. Modular structure
The unit has a popular panel structure, with modular double-layer sandwich panels made of polyurethane as the core material. The cross-section of the unit can be made in various shapes to meet different application needs. The扣板lock structure ensures all panels are flat, with a continuous and smooth surface, clear and seamless appearance.
High air tightness
Utilizing high elasticity sealing strips for airtight sealing between panels, frames, and other connecting components. Ensures the leakage rate of the enclosure meets the requirements of the GB/T 142-93 standard for clean air conditioning. Excellent heat insulation and condensation prevention.
4. Excellent corrosion resistance
Utilizing high-quality color steel plates, galvanized steel plates, cold-rolled steel plates, and shaped steel, all treated with phosphatization and electrostatic painting. The bolts, nuts, self-tapping screws, and other fasteners used are all corrosion-resistant.
5. Various heat exchanger designs
A variety of heat exchanger designs, including fin type, fin spacing, circuit layout, and row numbers, can meet the thermal performance requirements for different applications.
6. Dry Water Pan
The water pan features a sloping design, ensuring unobstructed condensate drainage and keeping the pan in a dry state at all times. It minimizes harmful health factors to the utmost.
7. Low-noise energy-saving model
High efficiency, low noise centrifugal explosion-proof exhaust fans with dual air intake. All fans undergo rigorous static and dynamic balance tests. They come in forward multi-blade, rear-arc, and rear-wing types. Selection is based on parameters such as air volume, pressure, noise, and power. The fans also feature anti-static treatment.
8. Easy installation
Each functional section is connected on-site using clamping devices and bolts, reducing assembly time and allowing for disassembled assembly according to customer requirements.
9. Easy maintenance
Each functional section of the cabinet is equipped with a specially designed, airtight plastic-steel maintenance door, which also utilizes a clip board locking structure for easy opening and closing, facilitating the maintenance of internal components of the unit.
10. Aircraft Assembly
Available for outdoor, clean room, and microelectronics room units, as per engineering specifications.
11. Electro-Mechanical Integration
Available for optional installation of variable frequency drives, blower starters, and automatic control devices to achieve year-round energy-saving operation of the unit. Equipped with communication interfaces for integration with building automation systems to enable networked centralized control.
Explosion-proof modular air conditioner features:
The explosion-proof modular air conditioner is a type of air treatment equipment assembled from various air handling units, which does not come with its own cooling or heating sources. It can achieve a variety of functions such as explosion-proof cooling, dehumidification, humidification, and heating. Various models of air conditioning units come with multiple functional sections that can be combined and selected as needed by design units and users. Additionally, customized air conditioning units can be designed and manufactured according to the specific requirements of the users.
(1) New mixed return air section
The new return air segment can be positioned at the end, top, or on each side according to design requirements. If it differs from this sample, please provide the specific opening position. A explosion-proof regulating valve can be mounted on the new return air opening. The actuator is available in manual and electric types, allowing the user to choose.
(2) Filter section
Available in primary and medium efficiency filtration, equipped with diamond-shaped baghouse and four-peak baghouse designs. The filter media is made of polyester non-woven fabric, and features a quick assembly and disassembly mechanism for the filter, along with a differential pressure display and alarm system.
(3) (New) Exhaust Section (also known as Flat-Top Dividing and Mixing Section)
This section features a one-time return air valve. Each side of the valve is equipped with an exhaust and an intake air port on the top of the box. It is equipped with an adjustable valve. Its function is: when there is a return fan, it supplies part of the return air from the air conditioning unit's power plant, allowing the fresh air and the first return air to mix in the required ratio. The air valve can be fitted with a manual, electric, or pneumatic actuator, and the user can choose as preferred.
(4) Intermediate Section (Maintenance Section)
This section serves as a connection for the filter section and internal maintenance lighting within the unit. Prior to the filter section, an intermediate section must be installed before and after the cooling section, heating section, and sound absorption section.
(5) Second Air Recirculation Section
Intermediate section for connecting the secondary return air duct: Equipped with adjustable valves at the top, available with manual, electric, or pneumatic regulating mechanisms, user selectable; this section can also be integrated into the supply fan section.
(6) Condenser Section
The condenser employs a copper tube structure with four, six, or eight rows of fins, featuring double-flanged corrugated aluminum foil. The large-radius bended heat exchanger reduces 60% of welding elbows, enhancing heat exchange efficiency, and the mechanical expansion form ensures optimal contact performance of the heat exchanger.
(7) Heating section
For steel pipe heat exchangers with steel sheet or copper tube with aluminum foil wrapped around 1st, 2nd, and 4th rows, the heat medium is steam or hot water.
(8) Energy Recovery Segment
To set up a heat recovery wheel for ventilation, by utilizing the energy exchange between indoor exhaust air and outdoor fresh air, the purpose of energy saving is achieved. In winter, preheat the fresh air; in summer, precool the fresh air; the recovery efficiency is approximately 70%.
(9) Blower Section
A. S-Type Air Delivery Section: Features horizontal air delivery, with a flexible hose at the fan outlet and a spring-damped steel frame at the bottom for reduced vibration. Suitable for installation on floor slabs, the air handling unit's fan employs a double-inlet centrifugal explosion-proof fan.
B. H-type Supply Fan Section: A vertical upward supply fan section with a top-mounted flanged connection, treated with anti-static technology for the fan.
(10) Humidification Section
This humidifier offers three forms of humidification for user selection: dry steam humidification, high-pressure spray humidification, and wet film humidification.
a. Dry Steam Humidifier: Available in three control types - manual (SZS), pneumatic (QZS), and electric (DZS). This humidifier features rapid humidification, drip-free operation, low running costs, and excellent humidification performance, suitable for locations with steam sources.
b. High-pressure Spray Humidification: This system employs a direct-connected high-pressure pump to increase water pressure to 0.35 MPa, forcing it through a new type of nozzle to produce water mist for humidification. Its features include high atomization efficiency (with an average droplet size SMD of 38.6 um measured on an mzlvcm laser particle analyzer), resulting in a large humidification capacity and rapid humidification speed. It is five times more efficient than similar spray chamber humidifiers, consumes less electricity, and comes with an in-built water filtration unit. It is easy to use and maintain, making it particularly suitable for humidification without steam sources.
(11) Muffler section
This noise attenuation section features impedance composite ceramic mufflers and metal micro-perforated plate mufflers. The metal micro-perforated plate mufflers offer advantages such as high-temperature resistance, moisture resistance, and dust-free operation. Users can choose according to their specific needs.
(12) Electric Heating Section
The heating air is achieved using PTC heating elements, suitable for use when there is no hot water, steam, or other heat sources.
(13) Flow Equalization Section
The use of diffuser plates for uniform air distribution ensures excellent distribution performance and low air resistance. This section is located after the fan section, achieving uniform velocity across the equipment cross-section.
(14) Exhaust section
The outlet position can be set at the ends, top, or on each side as per design specifications. If it does not match the sample, please provide the specific opening location. A regulating valve is installed on the outlet, which can be equipped with a manual, electric, or pneumatic actuator, allowing the customer to choose.
(15) Maintenance Section
The section is equipped with a maintenance door for repair needs, featuring both negative and positive pressure doors. The maintenance door frame is made of plastic steel profile, offering good sealing performance, easy operation, and space-saving design.
Specification Parameters:
Project | BZKT-70 | BZKT-140 | BZKT-210 | BZKT-280 | BZKT-350 | BZKT-420 | BZKT-490 | BZKT-560 | ||||||||||||||||||||
Nominal | kW | 70 | 140 | 210 | 280 | 350 | 420 | 490 | 560 | |||||||||||||||||||
Cooling capacity | kcal/h | 60300 | 120600 | 180900 | 241200 | 301500 | 361800 | 422100 | 482400 | |||||||||||||||||||
Model | Totally enclosed compressor | |||||||||||||||||||||||||||
Number of motors | 20.5 x 1 | 20.5x2 | 20.5 x 3 | 20.5x4 | 20.5x5 | 20.5 x 6 | 20.5 x 7 | 20.5 x8 | ||||||||||||||||||||
Noise dB(A) | 55 〜60 | |||||||||||||||||||||||||||
Refrigerant | Refrigerant | R22 | ||||||||||||||||||||||||||
Charging Quantity in Kg | 11 | 11 x 2 | 11 x 3 | 11 X 4 | 11 x 5 | 11 x 6 | 11x7 | 11 x 8 | ||||||||||||||||||||
Condenser | Type | Plate Heat Exchanger | ||||||||||||||||||||||||||
Flow Rate: m³/h | 15.5 | 15.5x2 | 15.5 x 3 | 15.5 x 4 | 15.5x5 | 15.5x6 | 15.5 x 7 | 15.5x8 | ||||||||||||||||||||
Water resistance loss kPa | 59. 1 | |||||||||||||||||||||||||||
Pipe fitting size | All specifications and sizes are DN50 (2'). | Pipe | ||||||||||||||||||||||||||
Style | Plate Heat Exchanger | |||||||||||||||||||||||||||
Please provide the Chinese content you would like translated into American English. | Flow Rate: m³/h | 12.0 | 12.0 x 2 | 12.0 x 3 | 12.0x4 | 12.0 x 5 | 12.0x6 | 12.0 x 7 | 12.0x8 | |||||||||||||||||||
Appliance | Hydrodynamic resistance loss kPa | 33. 9 | ||||||||||||||||||||||||||
Pipe Fitting Size | All specifications and sizes are DN50 (2'). | Pipe | ||||||||||||||||||||||||||
Electrical appliances Available | Power Supply | 3ph-50HZ-380V | ||||||||||||||||||||||||||
Total Power kW | 20.8 | 20. & 2 | 20.8x3 | 20.8x4 | 20.8x5 | 20.8x 6 | 20.8x 7 | 20.8x8 | ||||||||||||||||||||
Safety Protection | High and low voltage switches, anti-freezing protection, time-delayed compressor start protection, phase loss and phase error protection, overcurrent protection, compressor overheating protection, sensor failure protection | |||||||||||||||||||||||||||
Dimensions mm | Long | 1200 | ||||||||||||||||||||||||||
Wide | 760 | 1920 | 3080 | 4240 | 5400 | 6050 | 7720 | 8880 | ||||||||||||||||||||
Gao | 1250 | |||||||||||||||||||||||||||
Weight: kg | 320 | 640 | 960 | 1280 | 1600 | 1920 | 2240 | 2560 | ||||||||||||||||||||