Features and Maintenance Methods of the QDLF Vertical Multi-Stage Pump for Stainless Steel_News Center Co., Ltd._Features and Maintenance Methods of the QDLF Vertical Multi-Stage Pump for Stainless Steel,Shaanxi Hongwei Environmental Protection Water Supply Equipment Co., Ltd._Shaanxi Hongwei Environmental Protection Water Supply Equipment Co., Ltd._Zhongshang 114 Industry Resources Network
Shaanxi Hongwei Environmental Protection Water Supply Equipment Co., Ltd.

Pumps | Water Supply Equipment | Stainless Steel Water Tanks | Sewage Lift Stations | Oil and Waste Water Integrated Lift Equipment | Full Process Comprehensive Water Treatment System

Consultation Hotline
13032992066  13032992066
 

Company Information

Location:Shaanxi

会员级别:标王3

身份认证:   

我的勋章:  通过中商114认证 [诚信档案]

Business Card

  • 公司名称Shaanxi Hongwei Environmental Protection Water Supply Equipment Co., Ltd.
  • 联 系 人任经理 (女士)
  • 公司电话13032992066
  • 手机号码13032992066
  • Company Address25#, Building 1, Phase 6, High-tech Zone, Xi'an City, Shaanxi Province, China
home > News Center Co., Ltd. > Features and Maintenance Methods of the QDLF Vertical Multi-Stage Pump for Stainless Steel
News Center Co., Ltd.
Features and Maintenance Methods of the QDLF Vertical Multi-Stage Pump for Stainless Steel
Publish Time:2022-09-23        View Count:15        Return to List

The QDLF Vertical Multi-Stage Stainless Steel Pump is structurally designed in a vertical, segmented form, with the pump's suction and discharge ports arranged in a straight line at the bottom, utilizing an optimal hydraulic model. The axial force of the pump is resolved by a hydraulic balancing method, with any residual axial force absorbed by a ball bearing, ensuring smooth operation, low noise, small footprint, and ease of installation. The outer casing of the pump is made of stainless steel, featuring an attractive appearance, making it particularly suitable for parallel use of multiple pumps in high-rise buildings to reduce the power requirement of individual pump units and simplify the electrical control equipment. It is applicable for fire protection, domestic water supply, and air conditioning system circulation, as well as cooling water transport in both high-rise and low-rise buildings.

The product features of QDLF vertical stainless steel multi-stage pumps include:

Low Noise: Equipped with a Y2-type optimized motor, the operation is stable with low noise.

2. Leak-Free: Chosen for its mechanical seals, scientific machining processes, and technological assurance, the pursuit of "leak-free" has been achieved.

3. Easy Assembly and Disassembly: Rigid coupling, spline pump shaft design, and weighs approximately 50% less than cast iron pumps, offering superior operability.

4. Easy Installation: Inlets and outlets are on the same horizontal plane, reducing pipeline requirements and ensuring more reliable and stable pipeline usage.

5. Reduced Pump House Investment: An innovation on the original vertical multistage pump, featuring a smaller size and footprint.

6. Prevent Secondary Water Pollution: Made of stainless steel for the guide components and shafts, this design overcomes the severe pollution issue of cast iron pumps, ensuring the quality of water.

7. Rust-Free Assurance: Utilizing stainless steel sleeves, offering enhanced adaptability to various environments and lasting rust resistance.

8. Longer lifespan: Stainless steel plate stamped and welded impeller, lightweight with excellent balance, stable operation.

Low maintenance costs: Utilizes the WaterWet design for increased reliability in operation, requiring no lubrication or maintenance.

10. Environmental and Energy Efficiency: Improved hydraulic models and smooth flow components significantly enhance mechanical efficiency.

Maintenance of the QDLF Vertical Multi-Stage Stainless Steel Pump:

Prior to the start-up of the multi-stage centrifugal pump, ensure that the pump is not powered on and that it cannot suddenly start up.

2. The bearings and shaft seals of the light centrifugal pump are maintenance-free. In case the pump is to be drained after a long period of non-use, remove one of the coupling guard plates and apply a few drops of silicone oil onto the shaft between the pump head and the coupling. This will prevent the shaft seal surface from sticking together.

When installing the coupling guard plate, ensure they are vertically centered in the pump head's凹口.

4. Motors without grease nozzles do not require maintenance. Motors with grease nozzles should be lubricated with high-temperature lithium-based grease.

5. For pumps that are not used for a long time, it is recommended to clean and lubricate the pump and motor once they are put into storage.

6. During freezing periods, pumps should be drained to prevent damage and cracking. Unscrew the vent screw on the pump head and remove the drain plug from the base to allow the pump to drain. After the water is completely drained, the disassembled parts should be reassembled or properly stored.