Sells construction materials (excluding sand and stone as well as products th...
产品Price 1000.00/ton
最小起订Quantity:1 ton 供货总Quantity: 100 ton
C100 Large Equipment/Secondary Grouting Material for Wind Turbine Foundation/High-Flow Self-Compacting Non-shrink grouting material is made by cement as the binder, supplemented with high fluidity, slight expansion, and anti-segregation substances. It can be used after adding a certain amount of water at the construction site and being well mixed. The grouting material features good self-leveling, rapid hardening, early strength, no shrinkage, slight expansion; non-aging, non-corrosive to water quality and surrounding environment, good self-sealing properties, and anti-rust characteristics. It offers advantages such as reliable quality, cost reduction, shortened construction period, and ease of use for the construction party. It fundamentally alters the load-bearing condition of the equipment base, enabling it to uniformly bear the full load of the equipment, thereby meeting the installation requirements of various mechanical and electrical equipment (heavy equipment). It is the ideal grouting material for the era of padless installation. Product Features Primarily used for: anchor bolt anchoring, emergency repairs of airport runways, fixation of nuclear power equipment, reinforcement of road and bridge projects, machine bases, steel structure foundation sockets, secondary grouting of equipment foundations, embedding rebars, reinforcement and retrofitting of concrete structures, crack treatment of old concrete structures, installation of mechanical and electrical equipment, track and steel structure installation, statically pressed pile engineering pile sealing, building reinforcement, increased cross-sections of beams and columns, thickening of wall structures and water leakage treatment, grouting for various foundation collapses, and various emergency repair projects. Steel Reinforcement Suitable for bending, shearing, and tensile stresses in beam, slab, and column components primarily subjected to static loads, as well as for reinforcement of columns under compression. If used for reinforcement of beams and slabs under compression or for components with significant dynamic loads, additional anchoring measures should be added; for example, every100mmConfigure2A grouted bolt or tension bolt for through-beam or through-plate anchoring. Suitable for reinforcement against bending, shearing, and tensile forces in beams, slabs, and columns, and for reinforcing components subject to significant dynamic loads. The application scope is the same as (AFor components requiring a significant increase in load-bearing capacity. Application Range Ideal for anchoring new and old components subjected to bending, shearing, compression, and tension. Chemical grouting for crack reinforcement restores the integrity and functionality of cracked concrete and masonry components, blocks medium erosion, and repairs and reinforces holes, depressions, and insufficient cross-sections in concrete and masonry components. Suitable for reinforcing beams and slabs against bending and tension. Section reinforcement, suitable for structures requiring increased self-weight, cross-sectional area, and aesthetic changes. Product Categories 1主要用于: base bolt anchoring, reinforcement cutting and embedding, grouting layer thickness30mm<δ<200mmThe secondary grouting of equipment foundations with oil-resistant requirements is referred to as general grouting material. 2主要用于: Grouting layer thickness≥150mmThe secondary grouting of equipment foundations. Reinforcement and strengthening (修补厚度 repair thickness) of the beams, slabs, columns, foundations, and floor slabs of the building.≥40mmEquipment foundation secondary grouting with oil-resistant requirements, referred to as reinforcement work. Grouting material. 3主要用于: Prestressed duct grouting, grouting layer thickness10mm<δ<150mmReinforcement angle steel grouting between concrete beams and columns, and secondary grouting of equipment, referred to as concrete joint grouting Grouting material. 4Primarily used for: installation of large and complex equipment; reinforcement and renovation of concrete structures; rapid road paving; shrinkage-free grouting material. 5Primarily used for: high-temperature environments Grouting material, with high-temperature stability and excellent thermal shock resistance, equipment can remain in high-temperature radiation for extended periods.500℃ environment, grout layer thickness30mm<δ<200mmThe equipment foundation secondary grouting, known as heat-resistant grouting material. 6Primarily used for: Short construction time.2Hour Intensity ReachedC20Ready-to-run equipment, grouting layer thickness30mm<δ<200mmRush-pouring concrete to expedite project timeline, referred to as emergency repair work Grouting material. 7Primarily used for the grouting needs of large-volume, tall, and complexly structured equipment, ensuring no dead corners are left ungrouted. Offers excellent stability, suitable for special large-scale heavy-duty equipment. Grouting material, equipment for large-scale heavy industrial machinery Grouting material. 8主要用于: rapid strength gain at sub-zero temperatures, unaffected by frost damage, anchoring of base bolts, embedding reinforcing bars, and grout layer thickness30mm<δ<200mmThe secondary grouting of equipment foundations based on the equipment base. For equipment foundations with oil resistance requirements, the secondary grouting is referred to as antifreeze grouting material.



