Post-tensioned bridge steel strand hole grouting expansion material - grouting agent manufacturer_SupplyPro Co., Ltd._Beijing Shunjian Xingye Engineering Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Beijing Shunjian Xingye Engineering Technology Co., Ltd.

Sells construction materials (excluding sand and stone as well as products th...

15010423726 13331114929

Post-tensioned bridge steel strand hole grouting expansion material - grouting agent manufacturer

产品Price 1000.00/ton

最小起订Quantity:1 ton 供货总Quantity: 100 ton

用手机扫描二维码直达商品手机版
MobileView details
Location:
Beijing
有效期至:
长期有效
最后更新:
2022-04-06 09:13
Product Details

Post-tensioned bridge steel strand duct grouting expansive material - grouting agent manufacturer

Product Introduction

 After the prestressing tendons are tensioned and anchored, the pre-stressed duct should be grouted as soon as possible.48hPre-stressed pipe grouting material excels in performance for this grouting requirement, featuring good fluidity, no bleeding or segregation, excellent durability, non-corrosion of prestressed steel bars, strong bonding with concrete, full grouting with early strength, slight expansion for high filling, and one-time grouting capability with dense paste inside the pipe without any voids. The product is easy to use, requiring only the addition of water before use, and complies with the "Technical Specifications for Construction of Highway Bridges and Culverts."JTG/T F502011"Railway Post-Tensioning Prestressed Concrete Beam Casing Grouting Technical Conditions"TB/T3192-2008) and "Pre-stressed Hole Grouting Agent"GB/T25182-2010Standard Requirements.

 Post-tensioned duct grouting material main properties

Item   Objective Performance specifications Test Results

Water-to-binder ratio%) 0.260.28 0.27

Setting Timeh Initial setting 5 8:30

Final Coagulation 24 11:30

Liquidity25℃)(s Initial liquidity 1017 15.2

30minLiquidity 1020 16.1

60minLiquidity 1025 17.4

Bearing Rate% 24hBleeding Rate 0 0

3hWire interstitial water rate 0 0

Pressure Leach Rate% 0.22MPa  (Hole vertical height ≤1.8mPlease provide the Chinese content to be translated.      2.0                1.0

0.36MPa  (Hole channel vertical height >1.8mPlease provide the Chinese content to be translated.  

Inflation Rate% 3h 02 0.3

24h 03 1.1

Fulfillment Qualified Qualified

Compressive StrengthMPa 3d 20 53

7d 40 67

28d 50 76

Flexural strengthMPa 3d 5 11.5

7d 6 12.6

28d 10 14

Corrosive effect on rebars Rust-free Rust-free

 

Section 3: Post-tensioned hole grouting material main features

    1Good liquidity, high strength, non-sweat, non-delamination.

    2Excellent durability, no aging, no corrosion to rebar, durable and robust.

    3The slurry has properties of full early strength and slight expansion.

    4The product boasts high compaction, allowing for one-time slurry application, ensuring a dense, gap-free slurry inside the pipeline.

    5Pre-stressed rebars are corrosion-resistant and have a strong bond with concrete.

    6Convenient to use, just add water and it's ready.

 

Four Post-tensioned duct grouting material application range

    Suitable for grouting operations in cement slurry, cement mortar, and cement concrete, particularly ideal for post-tensioning grouting construction in large-scale projects such as ordinary highways, expressways, high-speed railways, bridges, and nuclear power plants.

 

Five. Post-tensioned duct grouting material usage precautions

    1The manufacturing of prestressed steel strands, the installation of anchors and clamps, the application of prestress, grouting, etc., should meet the design requirements and comply withJTG/TF502011"Highway Bridge and Culvert Construction Technical Specification"TB/T3192-2008"Temporary Technical Conditions for Prestressed Concrete Precast Beams for Passenger Dedicated Lines"GB/T25182-2010Specification for Prestressed Channel Grouting Agent

    2The recommended water-cement ratio for mixing the cement slurry for prestressed pipe grouting is:0.260.28Add actual mixing water to the blender80%90%Start the mixer, uniformly add all the slurry material, stirring continuously as you add. Add all the powder material while stirring slowly.2minThen, stir quickly.1minAdd the remaining10%20%Mixed water, continue stirring1min

    3The duration from the completion of slurry mixing to its insertion into the bore should not exceed40min

    4The slurry should be continuously stirred before and during the injection process. Do not increase the fluidity of the cement slurry that has decreased due to delayed use by adding extra water.

    5During grouting, the slurry temperature should be maintained5℃~30Between ℃, otherwise measures should be taken to meet the requirements.

    6Pre-stressed pipe grouting material, with precise water measurement and strict adherence to the predetermined water-cement ratio when adding water; no arbitrary adjustment of water quantity is allowed.

 

Six. Post-tensioned duct grouting material packaging and storage

    1This product is packaged in a lined plastic woven sack, net weight40±1kg/Bag.

    2Store in a dry, well-ventilated room.

    3Shelf life: 6 months.