详情描述

Shenzhen Zhongnuo Testing Technology Co., Ltd. specializes in consulting services for explosion-proof CCC certification. We have an extensive portfolio of consulting cases in the field of explosion-proof 3C certification. We are well-versed in the application process and technical requirements for explosion-proof 3C certification, and we can provide clients with consulting services such as application assistance and factory audit guidance.
What is the difference between ATEX certification and CE certification?
CE certification is a mandatory certification in the EU market, and all equipment and products entering the EU market must pass the relevant CE directive certification.
For example, there are EMC directives, LVD directives, MD directives, ATEX directives, etc.
Different products are subject to different certification directives; the ATEX directive is specifically for explosion-proof equipment and products.
ATEX certification can be considered as the CE certification for explosion-proof products.
Each directive has different applicable standards; the ATEX directive applies to the EN60079 series.
Different explosion-proof types are applicable to various standard series.
For example, EN 60079.1 is the standard for explosion-proof, EN 60079.7 is the standard for increased safety, EN 60079.11 is the standard for intrinsic safety, and so on.
Learn more about ATEX certification and contact Shenzhen Zhongnu Inspection Technology Co., Ltd. for more information at any time!
电磁阀防爆CCC认证需要什么条件
Electrical equipment used in explosive gas environments applying for防爆CCC certification standards
Ex-proof Type: Intrinsically Safe
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment, General Requirements
GB/T 3836.4-2021 Explosive Atmospheres Part 4: Equipment protected by intrinsic safety "i"
Ex-proof Type: Intrinsically Safe
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.2-2021 Explosive Atmospheres, Part 2: Equipment protected by a flameproof "d" enclosure
Ex-proof Type: Increased Safety Type
Applicable Explosion-Proof Standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment, General Requirements
GB/T 36.3-2021 Explosive Atmospheres Part 3: Equipment Protected by an "e" Type of Increased Safety
Explosion-proof Type: Positive Pressure Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres – Part 1: Equipment – General Requirements
GB/T 3836.5-2021 Explosive Atmospheres, Part 5: Equipment protected by positive pressure enclosure "p"
Explosion-proof Type: Immersed in oil
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment, General Requirements
GB/T 3836.6-2017 Part 6: Equipment protected by liquid immersion type “o” for explosive environments
Extinguishing Type: Sand-filled Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment - General Requirements
Electrical Equipment for Explosive Gas Atmospheres - Part 7: Sand-filled "q" Type
Explosion-proof Type: "N" Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment General Requirements
GB/T 3836.8-2021 Explosive Atmospheres, Part 8: Equipment protected by "n" type of protection
Explosion-proof Type: Molding Sealed Type
Applicable explosion-proof standards:
GB/T 3836.1-2021 Explosive Atmospheres, Part 1: Equipment - General Requirements
GB/T 3836.9-2021 Explosive Atmospheres, Part 9: Equipment protected by "m" type of enclosures
电磁阀防爆CCC认证需要什么条件
Application cycle for explosion-proof 3C certification (excluding rectification and preparation time for the applicant)
Institutional review of application materials: 2 business days
2. Issue Test Task: Within 2 working days after completion of document review
3. Testing Cycle: Generally, a Testing Report will be issued within 30 working days after confirmation of sample receipt, depending on the completeness of the provided information and the requested explosion-proof type. If there are modifications during the testing process, the modification time will not be included. For composite types or tests with complex projects and longer cycles, the testing time will be extended.
4. Factory Audit: Schedule factory audit within 3 working days after issuing the Testing Report. Complete factory audit within 5 working days.
5. Frequency of Certification: An institution conducts a 5-workday review after the submission of the type test and factory reviewing report. A certificate is issued upon successful review.
电磁阀防爆CCC认证需要什么条件
Explosion-proof CCC Certification Body
China Quality Certification Center (CQC)
Fangyuan Mark Certification Group Co., Ltd. (CQM)
Nanyang Explosion Proof Electrical Equipment Research Institute Co., Ltd. (CNEX)
Shanghai Instrumentation & Automation System Inspection & Testing Institute Co., Ltd. (NEPSI)
China Innovation Sea (Tianjin) Certification Service Co., Ltd. (PCEC)
Jiamusi Explosion-Proof Electric Motor Research Institute (JEXM)
Explosion-proof 3C Certification Business Consultation Services - Shenzhen ZhongNuo Testing Technology Co., Ltd.