FRP Cooling Towers Supply Cooling Method
Publish Time:2022-11-30        View Count:25        Return to List

The choice of changing the cooling point in glass-fiber cooling towers from outdoor to indoor directly affects the cooling duration of the system. Assuming that the calculated water temperature required to end the air conditioning at this point is 12.7°C, considering the cooling tower's cooling capacity, pipeline, and heat exchanger losses, which cause the water temperature to rise by 4.5°C, it can be determined that the cooling tower cooling mode can be switched to when the outdoor wet-bulb temperature is equal to or below 8.2°C.

After selecting the glass fiber cooling tower based on the summer cold load and outdoor wet bulb temperature, it is also necessary to verify its cooling capacity under the cooling tower's cooling mode.

In indirect cooling systems, plate heat exchangers should be selected. Compared to traditional tube-and-shell heat exchangers, plate heat exchangers offer superior heat exchange capabilities.

In direct chilled systems, a bypass should be installed for the chilled water pump in the cooling water loop. When using the cooling tower for chilling, the chilled water pump is turned off, and the cooling water bypasses the pump. At this moment, the circulating water's dynamic force is supplied by the chilled water pump. Therefore, when planning the system, consider changing the chilled water pump.

In direct chilled system planning, it is crucial to prioritize the sterilization and filtration of cooling water to prevent blockage of the end pipes.

Considering that the cooling tower's cold range (the difference between the cooling tower's outflow temperature and the outdoor wet bulb temperature) decreases as the scale of the cooling media increases under specific outdoor wet bulb temperatures and building loads, it is feasible to employ a series configuration of cooling towers within a multi-tower system to enhance the cooling effect. This approach raises the outdoor replacement temperature for the cooling tower's supply method, subsequently increasing the duration of the cooling supply.

Glass fiber cooling tower manufacturers take into account that the primary function of cooling towers in providing cooling is during the filtering season in winter. Therefore, in regions with lower temperatures during winter, anti-freezing equipment should be installed in the cooling water system, such as setting auxiliary pipes or adding heaters.

Our fiberglass sewage cover products are suitable for various industries such as oil, chemical, urban sewage treatment, food, metallurgy, compound fertilizer, and light纺织dyeing. They offer excellent performance in odor control, corrosion prevention, and thermal insulation during wastewater treatment. What are the notable features of our products?

1. Strong Corrosion Resistance: This product is manufactured using acid and alkali-resistant, corrosion-proof resins as the base material. It employs an excellent curing formula and advanced curing technology. Based on the specific conditions and shapes of each wastewater pond, a particular mold is confirmed for the outer mold curing and shaping process.

2. Cost-effective and Long-lasting: Compared to other wastewater treatment deodorization solutions, this option is cost-effective, with simpler installation and a longer lifespan.

3. Lightweight and High-Strength, Easy to Install: The glass fiber gas hood has a density only 1/3 to 1/4 that of steel products, high solidification, and can bear heavy loads, offering high strength. It is suitable for large-span pond structures. Additionally, the cover can be divided into several small sections, making transportation and installation convenient.

4. Aesthetically Pleasing and Aging-Resistant: This product features an anti-aging, weather-resistant, and UV-resistant polyurethane coating, which provides a smooth, attractive appearance with vibrant colors and a lifespan of over twenty years.

5. Low operational costs and easy maintenance: Due to its high corrosion resistance and aging resistance, this product does not require regular protective maintenance like metal products, resulting in significantly reduced costs. The canopy is equipped with observation windows and a service door at the end for easy maintenance by workers without disrupting the normal operation of the equipment.

6. Strong Planning Flexibility: Products can be flexibly planned based on the specific conditions of the on-site pond, with shapes available in arched lids, round lids, flat lids, and more.