Application of Desulfurization Flue Gas Damper
Publish Time:2022-04-07        View Count:80        Return to List

The desulfurization flue gas damper is a device used to connect the boiler system to the FGD system, affecting both applications. The flue gas damper serves as the inlet damper, outlet damper, and bypass damper in the FGD system. Under normal operation, flue gas enters the booster fan from the dust collector at the rear of the boiler through the inlet damper of the FGD system. After being cooled by the heat exchanger, the flue gas enters the absorption tower. The desulfurized flue gas is then reheated to approximately 80℃ by the flue gas heat exchanger and exits through the outlet damper of the FGD system into the chimney, where it is released into the atmosphere.

The Desulfurization Flue Gas Damper is produced by our Juzheng Machinery Co., Ltd. using advanced foreign technology. It is used in the inlet and outlet of the absorption tower in flue gas desulfurization systems, or in bypass flue gas channels, as well as in flue gas denitrification and dust removal systems. The air damper typically features a double blade structure with louvers, and when closed, a seal is inserted between the double blades to isolate and shut off the flue gas. The desulfurization flue gas damper is used for regulating flow in flue and air ducts, and within the 90° rotation of the damper, different positions can achieve automatic regulation through varying working fluid flow rates.

Technical Parameters of Desulfurization Flue Gas Damper

1. Flue Cross Section: D (Width) × W (Height) × L (Thickness)

2. Applicable Media: Cold and Hot Flue Gases

3. Temperature Resistance: ≤300℃

Design Pressure: ±8500 Pa

5. Leak Rate of Smoke Inside and Outside: "0"

6. Drive Method: Electric or Pneumatic

       Power and control requirements: selected by the user.

Blue Sky City Blue Sky Co., Ltd. is a specialized manufacturer of desulfurization flue gas damper doors and a series of damper door products. The company boasts a team of engineering technicians with extensive professional knowledge, capable of independently developing and designing various new types of rolling machines, and has established a comprehensive pre-sales, in-sales, and after-sales service system. Welcome both new and old customers to visit, consult, and discuss cooperation.