Our products include UPS uninterruptible power supplies, batteries, precision air conditioners, and integrated data center equipment.





价 格Negotiable
最小起订0 Piece库存0 Piece
Haiwu CSA3000 Precision Air Condi
Negotiable
Youlian VT1270
Negotiable
Eaton 9355 Marine UPS
Negotiable
Santak Castle Series Batteries
Negotiable
EasySmart Precision Air Condition
Negotiable
Cosel YDC3300-RT series mid-power
Negotiable
Santinel 2.0
Negotiable
Eaton 91PS & 93PS UPS
Negotiable
Inwin Talent ITalent Series Large
Negotiable
Santak ARRAY series batteries
Negotiable
| Model | SBP16GB8-P | SBP16GB6/2-P | SBP16GB12-P | SBP16IEC10/2 | SBP32GB12-P | SBP32GB10/2-P | SBP32GB16-P | |
| PDU Input | Rated Current | 16A | 16A | 16A | 16A | 32A | 32A | 32A |
| Voltage Range | 110~240V | 110~240V | 110~240V | 110~240V | 110~240V | 110~240V | 110~240V | |
| Rated Power | 4000W | 4000W | 4000W | 4000W | 8000W | 8000W | 8000W | |
| Input Plug | 16A Standard Plug | 16A Standard Plug | 16A Standard Plug | 16A Standard Plug | Wiring box | Wiring junction box | Wiring junction box | |
| Input Line Length | 2 meters | 2 meters | 2 meters | 2 meters | N/A | No content provided. | No content provided. | |
| Feature Module | SPD lightning protection | SPD lightning protection | SPD lightning protection | N/A | SPD lightning protection | SPD lightning protection | SPD lightning protection | |
| PDU output | Socket Type | Three-eighths National Standard Hole | 3-Flat National Standard Holes | 3 Flat National Standard Hole | IEC socket receptacle | 3/8" Standard Hole | Three Flat National Standard Holes | Three flat national standard hole |
| Rated Current | 10A | 10A/16A | 10A | 10A/16A | 16A | 10A/16A | 10A | |
| Number of outlets | 8 | 6+2 | 12 | 10+2 | 12 | 10+2 | 16 | |
| Mechanical appearance | Product Dimensions | 482*44.4*44.4mm | 482*44.4*44.4mm | 647*44.4*44.4mm | 482*44.4*44.4mm | 832*64*44.4mm | 832*64*44.4mm | 1002*64*44.4mm |
| Installation Method | Landscape/Portrait orientation | Landscape/Portrait orientation | Vertical Installation | Landscape/Portrait orientation | Vertical assembly | Vertical Mount | Vertical Installation | |
Basic PDU is widely used in electrical equipment distribution for various standard and non-standard cabinets, providing a safe and reliable power solution for rack-mounted equipment. SanTan Basic PDU offers a range of power input and output options, from AC to DC, single-phase to three-phase, 10A to 63A, fully customizable to user needs.
Safe and reliable materials
• The module shell is made of PC/ABS composite engineering plastic, containing an oxygen-free factor. The flame-retardant grade reaches UL94-V0 standard, offering excellent flame resistance and prominent fireproof characteristics. It also boasts high wear resistance, impact resistance, moisture resistance, and high insulation properties, effectively preventing electric shock hazards during use.
• The spring blades are made of phosphor bronze, offering excellent conductivity, elasticity, wear resistance, anti-magnetic properties, and corrosion resistance; the blades are formed through a whole stamping process with fine machining, ensuring a single-pole insertion and extraction life of over 5,000 cycles, guaranteeing high-reliability electrical conduction.
Other critical components are certified with strict safety standards such as UL, CE, and 3C, ensuring high reliability.
Optimized structural design
The housing is made of lightweight aluminum alloy material, offering advantages such as low weight, excellent heat dissipation, and high strength; internally, high-performance insulating material is used to isolate the live parts from the housing, in conjunction with grounding equipment, ensuring the equipment is safe and reliable.
• Connections between socket modules and various functional modules are made using terminal and bus connections. A single point failure does not affect the connection at other points, ensuring a safe and reliable connection.
• Optimized internal structure design with ample space for heat dissipation; under full load operation for one hour, the temperature rise is only 13-28℃, significantly lower than the national standard of 45℃.
Convenient and flexible installation
• Standard with 90°earhooks, the PDU can be securely mounted in a 19-inch standard rack with just 2 to 4 screws.
• Some products can be installed horizontally or vertically without occupying the cabinet's effective space.
Customized cabinet power distribution solution
All product features are designed and manufactured in a modular structure. Tailor-made professional cabinet power distribution solutions can be customized according to the user's power environment, ensuring cabinet power distribution safety and reliability.
Plug types and input methods can be flexibly selected according to the power distribution environment of the server room.
• Offers a rich selection of control and protection function modules to meet the requirements of power distribution protection under different environments.