Specializing in the production of customized LNG tanks_SupplyPro Co., Ltd._Shandong Zhongjie Special Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Shandong Zhongjie Special Equipment Co., Ltd.

Zhongjie Special Tank Co. specializes in the installation services of LNG tan...

Consultation Hotline
15253010956  18769007684

News Center Co., Ltd.

Product Categories
  • No Category

Contact Information
  • Contact person:于秋波
  • Telephone:15253010956
  • 邮件:931369632@qq.com
  • Mobile:18769007684

Home > SupplyPro Co., Ltd. > Specializing in the production of customized LNG tanks
Specializing in the production of customized LNG tanks
品牌: Zhongjie
Inventory Quantity: 9999
Operating Voltage: 380v
Effective Water Volume: Please inquire in detail.
单价: 1.00/Tai
最小起订Quantity: 1 Tai
供货总Quantity: 9999 Tai
有效期至: 长期有效
最后更新: 2025-05-28 15:03
 
详细Info

 60CubeLNGStorage Tank Technical Specifications:

Container Type: IICategory   Structure Type: Horizontal   Insulation Method: Vacuum Powder Insulation (Pearlescent Sand)        

Please provide the Chinese content that needs to be translated into American English.    Quality: LNG(Liquefied Natural Gas (LNG)      Maximum Allowable Working Pressure:0.86Mpa      

Design Temperature: Inner Shell:-196           Outer Shell:-20-50

Work Pressure:0.8Mpa  Outer case:-0.1 MPa Design Pressure:0.84Mpa Outer Shell:-0.1 MPa   

Available    Accumulated:60m3   Effective Volume:54m3 Material: Inner ShellS30408    Outer Shell:Q345R

Spec: Inner Shell:?2400×12400×7/Outer Shell:?2900×13140×8/10 Total Length:14929mm
  Total Weight:21760kg      Laminate Spacing:250mm       Inner tube material:S30408       Dimensions?2916×14929mm

Insulated Sandwich Material:TCHP-50Pearlized sand    Fill Volume: >30.8m3

Internal Cylinder Pressure Test: Medium: Nitrogen         Test Pressure:1.06Mpa

Valves; Low-temperature stainless steel gate valves  Sealing vacuum degree: ≤5Pa    Static Evaporation Rate ≤0.316%/d

Vacuum Insulation Sandwich Leak Rate ≤2×10-6 Pa.m3/s Vacuum Insulated Double Skin Leak Rate ≤6×10-5 Pa.m3/s 

Manufacturing Acceptance Standards:

GB/T18442.1~18442.6-2011, TSG21~2016"Regulation for Solid Content"NB/T47042-2014 

60m3Horizontal Low-Temperature Liquefied Natural Gas Storage Tank Technical Specifications 

2Tank pipeline valve instrument list (domestic high-quality products)

Serial Number

Name   Please provide the Chinese content to be translated.    

Specs

Quantity

Factory   Home

1

Low-temperature long shaft stop valve

DN40

8Piece

Zhangjiagang Furui Special Equipment Co., Ltd.

2

Low-temperature Long Axial Stop Valve

DN25

2Piece

Zhangjiagang Furui Special Equipment Co., Ltd.

3

Low-temperature long shaft stop valve

DN10

1Piece

Zhangjiagang Furui Special Equipment Co., Ltd.

4

Needle valve

DN10

2Piece

Zhangjiagang Furui Special Equipment Co., Ltd.

5

Pipe safety valve

DN4

3Piece

Zhangjiagang Furu Special Equipment Co., Ltd.

6

Three-way valve

DN25

1Piece

Zhangjiagang Furui Special Equipment Co., Ltd.

7

Safety Valve

DN25

2piece

Zhangjiagang Furu Special Equipment Co., Ltd.

8

Level Differential Pressure Gauge

15KPa

1Set

Chengdu Lanshi, Sichuan

9

Vacuum Valve Assembly

DN30

1Set

Chengdu Lanshi, Sichuan

10

Oxygen Pressure Gauge

0-1.6Mpa

1Piece

Chengdu Tianwei



Heze Boiler Factory Co., Ltd.

Liquefied Natural Gas (LNG) storage tanks are composed of the tank body, instruments, pipelines, valves, etc. The LNG storage tanks are designed with two liquid inlet methods, the upper and lower sections, allowing for selection based on actual conditions.

The inner tank of the Liquefied Natural Gas (LNG) storage tank is equipped with a safety system consisting of dual safety valves. Under normal operation, one set is in active use while the other is on standby. In the event that the active safety valve trips, the manual pressure relief valve is immediately opened to depressurize below the tank's operating pressure. Simultaneously, the safety device is swiftly switched to the standby system, effectively ensuring the tank's safety. This safety system is composed of safety valves, explosion-proof devices, vent valves, and three-way ball valves, which not only reduce pipeline welding but also feature excellent fire and static electricity prevention structures. Additionally, the safety relief ports on the shell are designed to ensure the overall safety and reliability of the equipment. The low-temperature pipelines are集中引出 for ease of operation and control, and the outlet is structured with Dura Tube to accommodate low-temperature requirements and reduce stress caused by thermal expansion and contraction, ensuring the tank's safety. The vacuum pump valve is sealed with three "O" rings, effectively guaranteeing the reliability of the sandwich seal, and is made of full stainless steel with a compact size. The top of the LNG storage tank is designed with a suspended structure for easy transportation, lifting, and installation. The unique manhole design ensures the cleanliness of the interior when the inner container is sealed. Vacuum isolation valves and combined vacuum gauges are used on the LNG storage tank for easy measurement of the sandwich vacuum level and maintenance, extending the tank's lifespan and improving its quality. The LNG storage tank is equipped with a level gauge and a pressure gauge for local display of liquid level and pressure. The sandwich insulation material is high-quality domestic pearlescent sand, with the following performance parameters:

Serial Number, Indicator Name, Unit, Indicator

Loose Bulk Density: 50-60 Kg/m3

2 Grain size mm 0.1-0.2 not less than 80%

Thermal Conductivity (at atmospheric pressure, temperature 310-77K) W/m.k.s < 0.026

4 Moisture Content (Weight) % < 0.1

5 Non-puffed Rate % ≤1

6 Temperature ℃ -200℃ ~ 600℃

7 pH Level: 6.5-7.5

Section 3: Inspection, Testing, and Acceptance

1. Inspect the inner cylinder material; usage is permitted upon passing inspection.

2. All welds are inspected in accordance with the GB150.1-150.4-2011 standards and drawings. Upon passing the inspection, A and B class welds undergo 100% X-ray testing, C and D class welds are subjected to 100% penetrant testing, and a test report is issued.

3. After the cylinder assembly is complete, inspect the geometric dimensions, pipe end orientation, and shape deviations according to the GB150.1-150.4-2011 standards and drawings.

4. After passing the inspection, conduct a pressure test and issue a pressure test report. Once the pressure test is approved, proceed with vacuum extraction. After achieving the required vacuum level, perform a helium leak test.

5. After interlayer leak detection passes, fill with pearlescent sand and then vacuum pump. Seal and maintain the vacuum degree once it reaches the requirements of GB/T18442-2011 standard.

Section 4: Technical Documentation

1. After the contract is signed, the seller shall provide the following technical data to the buyer:

⑴ One set of product quality certificates for the equipment (provided with the equipment)

Including: Certificate of Material for Main Pressure Components, Bill of Materials, Structural Dimension Inspection Report, Inspection Plan, Product Compliance Certificate, Pressure Vessel Product Data Sheet, Welding Records, Non-Destructive Testing Report, Pressure Test Report, Supervision and Inspection Certificate for Special Equipment Manufacturing (Local Inspection Authority), Product Brand Copy

⑵ As-built drawings, each 1 set (provided with the equipment)

Each set includes 1 copy of the strength calculation document (provided with the equipment)

Manuals each 1 set (provided with the equipment)

1 set of equipment process diagram and 1 basic reference diagram (to be provided within 7 days after contract signing)

⑹ Certificate of Conformity for accessories, 1 instrument calibration report (provided with the equipment)







专业承接LNG储罐定做-特价LNG储罐制造商-专用LNG储罐促销-专业LNG储罐供应商
询价单
 Click submit means you agree to《Service terms》《Privacy policy》

18769007684