Our company specializes in tank-type pressure vessels, which are among our key products. These include LPG storage tanks, liquid ammonia tanks, liquid chlorine tanks, propane tanks, pentane tanks, and low-temperature storage tanks for liquid oxygen and nitrogen. Particularly, our LPG storage tanks have reached mass production levels with a continuous production line, and various models are available in stock.
Table of Performance Parameters for Class III Storage Tanks
Tank Type Product Model Effective Volume m³ Working Pressure MPa External Dimensions mm
LPG Storage Tank
[On the ground]
WG 1.77-1400-551.77DN1400×2750
WG 1.77-1400-10101.77DN1400×5980
WG 1.77-1600-10101.77DN1600×4400
WG 1.77-2000-20201.77DN2000×5650
WG 1.77-2200-25251.77DN2200×5800
WG 1.77-2200-30301.77DN2200×7100
WG 1.77-2600-40401.77DN2600×6600
WG 1.77-2600-50(B)501.77DN2600×8500
WG 1.77-2600-60601.77DN2600×10360
WG 1.77-3000-1001001.77DN3000×13200
WG 1.77-3600-1201201.77DN3600×10500
WG 1.77-3600-1501501.77DN3600×13500
WG 1.77-3800-2002001.77DN3800×16300
LPG Storage Tank
[Below ground]
WDG 1.77-1400-551.77DN1400×2750
WDG 1.77-1600-10101.77DN1600×4400
WDG 1.77-2200-25251.77DN2200×5770
WDG 1.77-2200-30301.77DN2200×7100
WDG 1.77-2600-50501.77DN2600×8500
WDG 1.77-2800-60601.77DN2800×8740
WDG 1.77-3000-1001001.77DN3000×13200
Supplying listed company He Guo brand LPG storage tanks, ranging from 5 cubic meters to 200 cubic meters of LPG storage tanks.

Our company specializes in tank-type pressure vessels, which are one of our key products. These include LPG storage tanks, liquid ammonia tanks, liquid chlorine tanks, propane tanks, C5 storage tanks, and low-temperature storage tanks for liquid oxygen and nitrogen. Particularly, our LPG storage tanks have reached mass production levels with continuous production lines, and various models are available in stock. Available capacities range from 5 to 200 cubic meters, and we offer both above-ground and underground tanks.
Procedures for Safe Operation of Liquefied Petroleum Gas Aboveground Storage Tanks
1. Use tanks in accordance with national specifications and design parameters, strictly prohibit over-pressurization and over-liquid level operation.
2. Inspections are strictly conducted according to regulations; tanks that fail to meet standards are not to be put into use.
3. Various safety accessories of the storage tanks must be inspected regularly in accordance with regulations to ensure proper functioning.
4. Valves connected to the tank, including normally open and normally closed valves, must be clearly marked.
5. The liquid storage in tanks should be strictly controlled to no more than 85%, with clear level indicator markings.
5. Promptly empty the tank if it's found to be overfilled.
6. Conduct daily routine checks of the tank's pressure, temperature, and liquid level; address any anomalies promptly and report them.
7. When the summer temperature reaches above 35℃ and the storage tank pressure exceeds 10 kgf, the sprinkler cooling system must be activated.
8. When the winter temperature drops below 5°C, daily inspection and treatment of tank drainage should be conducted to prevent ice blockage.



专业定制液化气储罐批发价-知名液化气储罐生产厂家-供应液化气储罐公司-特价液化气储罐制造厂