KWKCL-200 Type Micro Coulomb Sulfur (Chlorine) Analyzer_SupplyPro Co., Ltd._Taizhou Galaxy Instrument Factory 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Taizhou Galaxy Instrument Factory

Rotary Disc Electrode, Microcoulometric Chloride Analyzer, Automatic Particle...

Consultation Hotline
13801421289

Product Categories

Contact Information
  • Contact person:宋经理
  • Telephone:13801421289
  • Mobile:13801421289

Home > SupplyPro Co., Ltd. > KWKCL-200 Type Micro Coulomb Sulfur (Chlorine) Analyzer
KWKCL-200 Type Micro Coulomb Sulfur (Chlorine) Analyzer
品牌: Galaxy Instruments
Model: KWKCL-200
Origin: Jiangsu
Shipment Scope: National
单价: 电议
最小起订Quantity:
供货总Quantity:
有效期至: 长期有效
最后更新: 2026-01-19 09:56
 
详细Info

KWKCL-200TypeMicrocoulomb Chlorine Analyzer

Principle

Instrument Principle: The sample is carried into the pyrolysis tube by the carrier gas and burned in the presence of sufficient oxygen, where the chlorine is quantitatively converted toHCL。HCLAbsorbed by the electrolyte and undergoes the following reaction:

HCL+Ag+=AgCl+H+

Reagent consumption in the electrolyte solutionI2OrAg+,Causing electricityThe electrode potential change in the reservoir is measured, and the instrument detects this change and providesElectricityDissolve an electrolytic voltage corresponding to the electrolytic electrode. Electrolyze on the electrode.I2OrAg+, untilElectricityDecanting TankI2OrAg+Restore to original concentration. The instrument detects the electrical energy consumed during this electrolysis process and calculates...ReactionConsumptionPlease provide the Chinese content to be translated.I2OrAg+Quantity, thus obtaining samples withCLConcentration.

Technical Specifications

I. Measurement Range:

       Cl 0.1-----10000ng/ul-----Percentage Content

II. Instrument Accuracy:

A:Concentration0.05-1.0 ng/ulAbsolute Sample Error:≤±0.1

B:Concentration1.0-10 ng/ulRelative Error of the Sample:≤10%

C:Concentration10 ng/ulThe relative error of the above samples:≤5%

III. Instrumental Repeatability Error:

A:Concentration:0.05-1.0 ng/ulAbsolute Sample Error:≤50%

B:Concentration1.0-10 ng/ulRelative Sample Error:≤10%

C:Concentration10 ng/ulRelative error of the above samples:≤5%

 

KWKCL-200Micro Coulomb Chlorine AnalyzerComposed of the main unit, temperature gas flow control unit, stirrer, sampler, computer, printer, etc.

The instrument is suitable for the analysis of total chlorine content in samples across various fields such as petroleum, petrochemicals, medicine, hygiene, environmental protection, coal, geology, metallurgy, commodity inspection, quality inspection, and educational institutions, for production, scientific research, and monitoring purposes.                                                

 

 

GB/T 18612-2001 Determination of Organic Chlorine Content in Crude Oil-Microcoulomb method

SH/T1757-2006 Determination of Organic Chlorine in Industrial Aromatic Hydrocarbons by Microcoulometry

 


询价单
 Click submit means you agree to《Service terms》《Privacy policy》

13801421289