GLC-201 Model Microcoulomb Sulfur (Chlorine) Analyzer_SupplyPro Co., Ltd._Taizhou Galaxy Instrument Factory 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Taizhou Galaxy Instrument Factory

Rotary Disc Electrode, Microcoulometric Chloride Analyzer, Automatic Particle...

Consultation Hotline
13801421289

Product Categories

Contact Information
  • Contact person:宋经理
  • Telephone:13801421289
  • Mobile:13801421289

Home > SupplyPro Co., Ltd. > GLC-201 Model Microcoulomb Sulfur (Chlorine) Analyzer
GLC-201 Model Microcoulomb Sulfur (Chlorine) Analyzer
品牌: Galaxy Instruments
Model: GLC-201
Origin: Jiangsu
Shipment Scope: National
单价: 电议
最小起订Quantity:
供货总Quantity:
有效期至: 长期有效
最后更新: 2026-01-19 10:20
 
详细Info

 GLC-201TypeMicrocoulomb Sulfur Determination MeterIsWK-2DEnhanced version,The instrument operates on the principle of dynamic micro-coulometry.Designed and processed with microcomputer technology, directly displaying samplesTotal Sulfur or Total ChlorineContent.

Instrument Principle: The sample is carried into the cracking tube by the carrier gas and fully combusted with oxygen, during which the sulfur or chlorine is quantitatively converted intoSO2OrHCL。SO2OrHCLAbsorbed and reacts with the electrolyte:SO2+H2O +I=SO+2H++2I-   OrHCL+Ag+=AgCl↓+H+, Reaction consumes electrolyte solutionI2OrAg+,Causing electricityThe electrode potential change in the reservoir is measured, and the instrument detects this change and providesElectricityA corresponding electrolytic voltage is applied to the electrolytic electrode. Electrolysis occurs on the electrode.I2OrAg+UntilElectricityDecant from poolI2Or Ag+Restore to original concentration. The instrument detects the electrical energy consumed in this electrolysis process, calculatesReactiveConsumptionPlease provide the Chinese content you would like translated into American English.I2OrAg+Quantity, thereby obtaining samples ofSOrCLConcentration.

GLC-201TypeMicrocoulomb Sulfur Determination MeterTechnical Specifications:

1.Measurement Range: 0.2-----5000mg/l      (Sulfur.Chlorine)

2.Sample testable status: Solid, liquid, gas (with corresponding sampler).
3.Temperature Control Range and Accuracy: Room Temperature ~1000℃±1% 
4.
Repetitive error: X1.0mg/<30%
              1.0mg/L≤X≤10mg/L<10%
              X
10mg/L<5% 

5. Current Occurrence:±2mAElectrolytic Voltage:±30VBias pressure range:0-500mV

6..Instrumentation package: Main unit (amplifier), temperature control (cracking) system, stirrer, sampler, computer (including operating software).
GLC-201TypeFeatures:
◆Chinese operating platform for computers, direct human-computer dialogue, easy to operate.
◆The computer controls the entire analysis process, including Chinese operation and data processing, displaying the working status of the entire process. Parameters and results can be saved or printed as needed.
◆The instrument utilizes popular circuits and imported components, reducing instrument noise and enhancing detection sensitivity.
◆Instrument measurement results are accurate and stable.

GLC-201TypeSatisfy GB17930-2008  SH/T 0254  SH/T0253  SH/T0222Analytical requirements for detecting trace amounts of sulfur and chlorine in petrochemical products, widely used in the oil, chemical, and scientific research sectors.


询价单
 Click submit means you agree to《Service terms》《Privacy policy》

13801421289