One: The training tower should be located near the end of the training field with a reserved runway, and a 1.5-meter sand pit should be reserved in front of the tower.
The training tower should consist of at least four floors, and in cities with a higher number of high-rise buildings, the number of floors may be appropriately increased.
The training tower features at least two windows per floor, with a spacing of 1.0 meter between the windows.
The training tower window dimensions are 1.2 meters by 1.8 meters, with the window at least 0.65 meters from the tower edge. The window sill width is 0.4 meters, and the sill board thickness is 0.05 meters (protruding 5 centimeters from the tower wall). The height from each window sill to the floor level of that floor is 0.8 meters, with a floor height of 3.5 meters. An internal staircase with a clear width of at least 0.7 meters should be provided, and the handrail tube diameter should not be less than 0.042 meters.
Fifth, a platform not less than 1.5 meters wide should be set on the inside of each floor of the training tower, and a floor should be set on the top level.
Six, it is advisable to install an outdoor fire escape ladder on the training tower. The ladder should extend to the top of the tower and ideally be set at a height of 3 meters above the ground, with a width not less than 60 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear skeletons, (4) observation and command platform skeletons, and the main steel structural frame. Simulated windows are installed at the front of the tower (custom-made with a specified number of floors and windows as needed), and floor partitions (steel plates) are placed between the upper and lower adjacent simulated windows. 2. A rear skeleton corresponding to the simulated windows is located at the bottom of the tower. 3. The simulated windows, floor partitions, rear skeletons, and main frame are bolted together. 4. Safety ladders connect each floor. 5. The upper part of the tower is equipped with an observation and command platform.
Seven, The training tower typically undergoes anti-corrosion treatment with spray painting, in a military green color. Alternatively, camouflage patterns or galvanizing are available. Eight, The steel structure fire training tower is fully functional, offering detachable and portable features, unrestricted by location, terrain, or plot size. It utilizes assembled components, characterized by low cost and high recyclability, which saves the unit expenses and achieves twice the training results with half the effort.