The measurement accuracy of the SSI oxygen probe varies with temperature changes. The zirconia oxygen probe maintains good measurement accuracy within a specific temperature range, but its performance can be affected by temperature control. For instance, when temperature control is unstable or inaccurate, it can impact the migration rate of oxygen ions and the generation of concentration potential, leading to measurement errors. Additionally, the operating temperature range of the SSI oxygen probe is typically between 700°C and 1100°C (1291°F to 2012°F), where the probe's measurement accuracy is usually ±0.1mV (dependent on the accuracy of the detection instrument). However, if the temperature exceeds the recommended range, the probe's measurement accuracy may decrease.