DRM-II Concrete Thermal Conductivity Tester, Heat Pulse Method Thermal Conductivity Meter
Details Introduction
XiangkeDRM-II ConcreteThermal Conductivity Tester, Thermal Pulse Method Conductivity MeterThermal Performance Tester
I. Overview
The instrument features: simple installation, high accuracy, and fast testing speed (about ten minutes per test), allowing simultaneous measurement of the thermal conductivity, thermal diffusivity, and specific heat of the material in a single test, and the ability to measure different concentrations.WetThermal physical properties under the state.Reference Standard:JGJT 12-2019(Replaces)JGJ 51-2002) (Lightweight aggregate concrete technical specifications),JG158-2004"Exterior Insulation and Finish System with Polystyrene Bead and Adhesive Powder"JG/T283-2010Appendix to "Expanded玻Alumina Microspheres Lightweight Mortar"BMeasurement of heat storage coefficient,JG/T511-2017Insulation Ceramic Insulation Board for Construction AppendixAMethod for testing thermal storage coefficient of foam ceramic insulationGB/T 20473-2021Insulation Mortar for Construction AppendixGHeat Retention Coefficient TestMethodsGB/T26000-2010Requirements for the determination method of heat storage coefficient in thermal insulation mortar with expanded vitrified microspheres.
Section II: Main Technical Performance
1Application Scope:
This instrument is suitable for measuring the thermal conductivity, heat capacity coefficient, thermal diffusivity, and specific heat of homogeneous plate, gel, powder, and granular materials under conditions of dryness or different moisture contents. The range of thermal conductivity of the measured material is0.035~1.7w/m.k
2Sample Size: One thin specimen20×20×(1.5~3)cm
Two thick samples20×20×(4~10)cm
3Electrical Source ~220V,50HZ
4Dimensions (Length x Width x Height) :Old modelSplit-type styleStyleMain Unit:600×450×700mm,
New one-piece style:340×700×560mm
5Working Conditions
Ambient Temperature 10~35Relative Humidity ≤80%
Room temperature requirements must be stable. ≤±1.5℃
6Accuracy of measurement results ±5%
7、DRM-IIConnect to the host computer,Automate computer testing and data printing output.
III. Basic Principles
DRMThermal Conductivity Test Instruments, based on the principle of non-steady heat conduction, briefly heat the experimental material, causing its temperature to change. By analyzing the characteristics of this change and solving the heat conduction differential equation, one can calculate the specific heat capacity, thermal conductivity, thermal diffusivity, and heat storage coefficient of the test material.
Instrumentation Configuration: IncludesDRM-IIOne main unit, one software set, one heater, one thermocouple set, one insulation bucket, one Lenovo desktop computer (configuration as per contract).