    Xiangtan XiangkeXRY-ll Heat Storage Coefficient Tester, Heat Storage Coefficient Measuring Instrument
    I. Overview
          The instrument can simultaneously measure the heat storage coefficient, thermal conductivity coefficient, thermal diffusivity coefficient, and specific heat of materials under different moisture conditions in a single test. The setup is simple, with high accuracy and fast testing speed (about ten minutes per test), with reference standards:JGJT12-2019(Replace)JGJ51-2002( Lightweight Aggregate Concrete Technical Code)AndJG/T283-2010Appendix to "Expanded玻urite Microspheres Lightweight Mortar"BMeasurement of the heat storage coefficient.
    II. Main Technical Performance
    1Application Range: This instrument is suitable for measuring the thermal conductivity, heat capacity coefficient, thermal diffusivity, and specific heat of homogeneous plate-like, gel-like, powdered, and granular materials under conditions of dryness or different moisture contents. The measured material's heat capacity coefficient range is0.1-30W/M2KThe thermal conductivity range of the material being tested is0.035~1.7w/m.k
    2Sample Size: One thin specimen20×20×1.5~3cmTwo thick trial pieces20×20×4~~10cm
    3Power Supply~~220V, 50HZ
    4Dimensions (Length)×Wide×High: Old style model:600×450×700mm,New Style:340×700×560mm
    5Work Conditions
    Ambient Temperature1035℃
    Relative Humidity≤80%
    Room temperature requirements must be stable.1.5℃
    6Accuracy of measurement results±5%
    7DRM-IIConnect to the host computer for automatic testing and data printing output.
    III. Basic Principles

    DRMThermal Conductivity Testers, based on the non-steady-state thermal conduction principle, heat the test material briefly within the experimental setup to alter its temperature. By analyzing the characteristics of this change, the heat capacity, thermal conductivity, thermal diffusivity, and specific heat of the test material can be calculated through solving the thermal diffusion differential equation.
    Instrumentation Configuration:

    1DRM-IIOne main unit (including a touch screen computer).2A complete software package,3One heater.4One set of thermocouples.5One thermal flask.