公司主营:Derivative Instruments, Expansometers, Multi-element Rapid Analyzers
13007446928


Product Center
Company Qualification
DRH-ZD-500 Insulation Material Sleeping Bag Thermal Conductivity Meter
Details Introduction
XiangkeDRH-ZD-500Thermal Insulation Material Camping Mattress Heat Resistance and Thermal Conductivity Tester (Protective Heat Plate Method)
The instrument employs the protective thermal plate method, primarily testing the thermal conductivity and thermal resistance of materials such as plastics, glass, fibers, foams, expanded cement, insulating materials, and camping mats. Instrument reference standard:GB/10294-2008Determination of Steady-State Thermal Resistance and Related Properties of Insulating Materials (Protective Heat Plate Method)ISO 8302-1991 Thermal Insulation: Determination of Steady-State Thermal Resistance and Related Characteristics - Protective Heat Plate MethodASTM-F3340-18Standard Test Method: The thermal resistance of camping mats is measured using a protective heat plate device.
Performance Features:
1Automatic Pressure System: Computerized automatic pressure application, capable of testing thermal conductivity under various pressure conditions. More scientific, data-driven, and repeatable compared to manual pressure application.
2Wide range of measurement types: In addition to measuring rigid panels, various accessories from our company can be selected to measure a variety of special materials, such as granular materials, loose materials, soil, etc.
Key Technical Specifications:
1Thermal conductivity range:0.0010~3.000W/mk;
2Test Accuracy:±3%;
3Thermodynamic Center Area:250×250mmPrecision of edge length0.01mm);
4Effective Test Area:500×500mmAvailable sample space800×800mm;
5Hot noodle temperature range: Room temperature ~100℃Temperature resolution0.01℃Measurement Accuracy:0.05℃Flexible printed circuit board method is used for the heat plate heating.
6Cold noodle temperature range:0~60℃Temperature resolution0.01℃;
7Computer-controlled full-automatic testing, data processing, and generation of test reports, with printable output.
8Automatically pressurizes, measures thermal conductivity at different pressure states, pressure range0—1000NAdjustable, Resolution0.1N。
9Cold and hot plate temperature difference: Default value30℃(Standard temperature difference commonly used), users can also set it themselves.
10Voltage:220V,50HZ.
Introduction to Measurement Equipment
DRH-ZD-500The instrument is primarily composed of a thermal plate temperature control system, a calorimetric power control system, a cold plate temperature control system, a specimen holding system, and a computer data control system. Optional accessories include a specimen thickness measurement system, a pressure measurement system, an electrically powered pressing system, and an external protective thermal environment temperature control system.
The hot plate is composed of a calorimetric plate and a heat-protective plate, internally equipped with a calorimetric flat plate heater (or an external water-loop isothermal tank control), a heat-protective flat plate heater, a calorimetric温差 thermoelectric silicon, and a temperature sensing probe. The heat-protective plate is temperature-controlled by a high-precision controller, providing a stable heat-protective temperature; the calorimetric plate is controlled by a high-precision controller to heat a DC constant-voltage power supply, with the calorimetric temperature controlled based on the calorimetric温差 thermoelectric pile signal, with the measured calorimetric power representing the heat flux; the surface temperature is measured by an embedded temperature sensing probe or an externally connected temperature sensing probe.
The cold plate contains water channels and temperature sensing probes, connected to an external constant-temperature water bath via pipes. It utilizes the medium circulation between the external constant-temperature bath and the cold plate to form a second constant-temperature field within the cold plate, providing a stable temperature at the cold face. The temperature of the cold face is measured by an integrated temperature sensing probe or an external temperature sensing probe. Depending on the temperature requirements, there are options for semiconductor refrigeration temperature control and electric heating temperature control.
The sample fixture is available in both manual and automatic types. Automatic fixture composition:1The sample thickness measuring device consists of a displacement sensor and a digital display meter, capable of real-time detection of the sample's thickness.2The pressure measurement system consists of a pressure sensor and a digital display gauge, capable of real-time testing of the sample's pressure.3The electric pressure system consists of a motor, a linear reducer (or stepper motor), an electronic speed controller, and a control circuit, achieving automatic pressure application and release.
The computer system handles data collection, processing, and instrument control, achieving full automation in testing.
Configuration: IncludedDRH-ZD-500One model test main unit, one software set, one high-precision constant temperature water bath, one desktop computer (as per contract specifications).




李经理 (Ms.)
13007446928
13007446928