The EDX8000T Coating Thickness Gauge is used for testing the silver plating thickness on copper foil surfaces._News Center Co., Ltd._Suzhou Infinis Science Instruments Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Suzhou Infinis Science Instruments Co., Ltd.

X-ray Fluorescence Spectrometer, Alloy Analyzer, Ore Analyzer, Precious Metal...

Tianzhu Hui Star Member
Consultation Hotline
15950921613  18962189136

Product Categories
  • No Category
Home > News Center Co., Ltd. > The EDX8000T Coating Thickness Gauge is used for testing the silver plating thickness on copper foil surfaces.
News Center Co., Ltd.
The EDX8000T Coating Thickness Gauge is used for testing the silver plating thickness on copper foil surfaces.
Publish Time:2023-11-28        View Count:37        Return to List

Copper foil is an excellent conductive material commonly used in electronic components such as circuit boards and electrolytic capacitors. However, in applications with high requirements for external environments, the conductivity of copper foil may be affected. In such cases, silver plating on the surface can effectively address this issue. The primary function of silver plating on copper foil is to enhance its corrosion resistance and conductivity. Silver is a chemically stable metal with high conductivity and thermal conductivity, excellent corrosion resistance, and electrochemical stability. Therefore, silver plating on the surface of copper foil can effectively prevent oxidation and corrosion of the copper layer, and improve its conductivity. Additionally, the silver coating can protect the copper foil surface from environmental erosion, enhance its durability, and thereby extend its service life. At the same time, the thickness of the silver coating directly affects the corrosion resistance and conductivity of the copper foil. Generally, the thicker the silver coating, the stronger its corrosion resistance and conductivity. Particularly in high-humidity environments or situations prone to acid and alkali corrosion, the silver coating plays an even more crucial role. For devices requiring precise control over the weight and dimensions of electronic components, a thicker silver coating will inevitably increase the weight and size of the components. Therefore, in practical applications, it is necessary to control the appropriate thickness of silver plating based on specific requirements and technical specifications. In conclusion, silver plating on the surface of copper foil is an effective method to improve its corrosion resistance and conductivity. The thickness of the coating directly impacts the performance of the copper foil, thus playing a significant role in product quality, process control, and cost control.



Innosense's EDX8000T Plus Coating Thickness Gauge is specifically designed for coating material composition analysis and thickness measurement. Its main advantages include accuracy, speed, non-destructiveness, ease of operation, and rapid measurement. It can simultaneously analyze the thickness of up to five layers of material and quickly identify the material composition of coatings. The Innosense Coating Thickness Gauge EDX 8000T Plus measures the thickness of coatings and metal thin films by irradiating the sample with X-rays and analyzing the intensity of the reflected X-rays. Since there is no contact with the sample and the X-ray energy applied is very low, the sample is not damaged. Additionally, the measurement can be completed in just 10 to 30 seconds.


During routine testing, the EDX8000T Plus membrane thickness gauge boasts the following features:

All-new downlight integrated design

> Quick Testing, No Sample Preparation Required

Observation and selection of the measurement of the thickness of the coating on a minute area can be achieved through an integrated high-definition CCD camera, avoiding direct contact, contamination, or damage to the object being measured. The software is equipped with distance correction algorithms, enabling testing of irregular samples (such as concave-convex surfaces, threads, curved surfaces, etc.).

> A variety of standard samples are available for measuring coating thickness and conducting composition analysis.

The SDD Detector, featuring a wide counting range and excellent energy resolution.

Automatically switch between collimators and filters


In addition, the EDX8000T Plus is also suitable for the following applications:

The EDX8000T Plus Coating Thickness Gauge is suitable for PCB coating thickness measurement and metal electroplating coating analysis.

The measured objects include coatings, laminates, overlays, coatings, and chemically formed films.

> Measureable thickness for various metal coatings such as ion plating, electroplating, vacuum deposition, etc.

Chrome-plated, such as plastic products with decorative chrome-plated finishes

Galvanized coatings on steel

Coating on circuit boards and flexible PCBs

Plug and electrical contact surface

Precious metal coatings, such as rhodium materials analysis on gold substrates

Analyze Functional Coatings in the Electronics and Semiconductor Industry

Analyzing coatings on hard materials, such as CrN, TiN, or TiCN

Expandable to include RoHS harmful element analysis and electroplating liquid ion concentration analysis