Two-compartment thermal shock_SupplyPro Co., Ltd._Suzhou Morning Sun Test Equipment Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Suzhou Morning Sun Test Equipment Co., Ltd.

Professional manufacturer of testing equipment

13812650780
0512-66361656
 

Product Categories

Contact Information
  • Contact person:张先生
  • Telephone:0512-66361656
  • Mobile:13812650780
  • Address:Yao Feng East Road, Mudu Town, Suzhou City
Home > SupplyPro Co., Ltd. > Two-compartment thermal shock
Two-compartment thermal shock
品牌: Morning Light Testing Equipment
Company: Changzhou Mingguang Test Equipment Co., Ltd.
Brand: Morning Light Testing Equipment
Region: Suzhou
单价: 999.00/Tai
最小起订Quantity: 1 Tai
供货总Quantity: 999 Tai
有效期至: 长期有效
最后更新: 2023-09-08 13:49
 
详细Info

I. Product Overview:
Adaptive tests for semiconductor devices, components, electronic products, and other equipment under rapid changes in ambient temperature. Vertical two-box structure, automatic control of high and low temperature box circulation process, adjustable dwell and transition times, stainless steel inner lining, multi-form recording, equipped with various safety protection measures and devices.
II. Compliant with Standards:
GB/T2423.1.2, GB10592-89, GJB150, CNS, MIL-STD-810D, IEC68-2-14, IPC-TM650, etc. standards.
Section 3: Container Structure:
All functions are computer-controlled with an improved user interface, making operation and monitoring simpler and more intuitive. It allows you to maintain the current state of your running program, temporarily alter the values of this program segment, and set time parameters on the screen for automatic switching of refrigeration, heating, and tray transfer to the set values. The cold box and hot box are independently controlled, with separate doors, expanding the usability of the test box (triple-use in one box). The thermal insulation effect of the product is fully guaranteed. The test box door, circulating fan, and tray conveyor are interlocked for operator safety. Power to the circulating fan and tray conveyor is automatically cut off upon opening the box door. Standard conduit holes are located on the top of the box for easy introduction of sensor lines, detection cables, and other types of wiring.
Four: Refrigeration System
Shanghai Shengshi Two-Box Type Cold and Hot Shock Refrigeration System and Compressor: To ensure the cooling rate and minimum temperature requirements of the test chamber, this chamber employs a binary cascade refrigeration system with an imported French fully enclosed compressor. The cascade refrigeration system includes a high-temperature refrigeration cycle and a low-temperature refrigeration cycle, connected by an evaporative condenser. The evaporative condenser plays a role in energy transfer, expelling heat energy from the workspace through two-stage refrigeration systems to achieve cooling. The design of the refrigeration system utilizes energy regulation technology, an effective approach that ensures normal operation of the refrigeration unit while effectively regulating the energy consumption and refrigeration capacity, thereby reducing the operational costs and failure rates to a more economical level. (Optional German GEA and Japanese Mitsubishi compressor units available.)
V. Refrigeration Working Principle:
Both high and low cooling cycles utilize the reverse Carnot cycle, which consists of two isothermal processes and two adiabatic processes. The process is as follows: The refrigerant is adiabatically compressed to a higher pressure by the compressor, consuming work and raising the exhaust temperature. Then, the refrigerant undergoes an isothermal heat exchange with the surrounding medium in the condenser, transferring heat to the medium. Subsequently, the refrigerant expands adiabatically through a valve, doing work and lowering its temperature. Next, the refrigerant absorbs heat from a higher-temperature object through the evaporator in an isothermal manner, thereby reducing the temperature of the cooled object. This cycle repeats indefinitely to achieve the cooling effect.
Refrigerants: Uses DuPont R404A (High Temperature Cycle), (Low Temperature Cycle).
Section 6: Control System
1 The controller is equipped with a Japanese UMC touch-color LCD microcomputer controller, which is aesthetically pleasing and beautiful. (Optional with Japanese OYO or American TEMI controllers.)
The product features a resistive high-precision touch screen for operation, allowing direct use of a USB mouse or a stylus to click on the screen for function selection or parameter setting.
3 The programmable function has a capacity of 160 Patten × 1600 step × 999 cycle.
4 Display Function: LCD screen display, capable of showing test conditions (including temperature ranges, cycle counts, running time, and remaining time, etc.).
5 Features programmable control and setpoint control for ease of use in various production conditions.
6 Set the temperature gradient to freely control running time and heating rate.
7 Schedule start-up function, once the system time reaches the set time, the system will automatically operate, allowing for flexible control over the aging room's running time and working conditions.
8 Power-off Restart Function, with options for Cold Start/Cold Restart/Interrupted Start.
9 The temperature control employs a synchronized coordination system of P.I.D. + S.S.R., which enhances the stability and lifespan of the control components and interfaces.
10 Real-time and historical curve queries for convenient observation of temperature changes.
11 Historical Data Transfer Function. Equipped with two USB ports for easy user data backup.
12 File Backup Feature.
13 Equipped with a computer connection interface, it can be connected to a computer for remote operation. Features include saving and printing of curves and experimental data.
14 Enable cumulative running function for customers to easily check product usage status for corresponding maintenance and care.
15 screen savers to better extend the lifespan of the LCD screen.
In case of system failure, it can display failure information, cause, and solutions.
17 Features permission level settings to prevent user errors.
18 English-Chinese Switch Function, convenient for users of different languages to operate.
19 Control Mode: PID (Proportional-Integral-Derivative) automatic calculation, PID control is simple and easy to understand, and does not require accurate system models or prerequisite conditions during use.
20 In settings, a warning signal is provided in case of errors.
21. Power on/off function (can control the test box's lighting with the controller), which can save costs for designers and enhance usability.
22 Temperature Sensor: Utilizes DIN PT-100Ω (Platinum Sensing Element).