Insulated Glass Water Vapour Sealing Durability Test Chamber
品牌: Morning Light Testing Equipment
Company: Suzhou Morgenlight Testing Equipment Co., Ltd.
Brand: Morning Light Testing Equipment
Region: Suzhou
单价: 999.00/Tai
最小起订Quantity: 1 Tai
供货总Quantity: 999 Tai
有效期至: 长期有效
最后更新: 2023-09-08 14:46
 
详细Info

Product Details:

1、 Product Name and Model

1.1 Product Name

Insulated glassWater and air tightness durability test chamber

1.2 Model No.

ZK-S-500L   

2、 Product Restrictions

This testing equipment is prohibited:

Testing and Storage of Samples of Flammable, Explosive, and Volatile Materials

Testing and Storage of Corrosive Material Samples

Biological sample testing or storage

Testing and Storage of Samples from Strong Electromagnetic Emission Sources

3、 Volume and dimensions

3.1 Nominal Cubic Content

3.2 Inner box size

3.3 Door opening size

3.4 Sample Capacity

0.5 cubic meters

700×800×900 (Depth × Width × Height mm)

800×900 (width × height mm)

Secure placement350mm x 500mm samples ≥ 20 pieces

3.5 Reference Image

image.png 

4、 Test Environment and Methods

4.1 Test Environment Strip

Ambient temperature: 5-35°C, relative humidity85%RH

No samples are contained within the test box (unless otherwise specified).

4.2 Testing Method

GB/T 5170.2 Temperature Test Equipment

GB/T 5170.5 Wet Heat Test Equipment

GB/T 11944-2012 Test Method for Water Seal of Insulating Glass

4.3 Load

Glass Sample Size: (510)±2)mm×(360±2)×20mm

Quantity: 20 pieces of glass (glass thickness: 22mm), glass spacing of 15mm or more

5、 Key Technical Specifications

5.1 Temperature Range

5.2 Temperature Fluctuation

5.3 Rise and fall of temperature rate

-30~+100

±0.5

0.7 to 1°C/min (no load)

5.4 Humidity Range

5.5 Relative Humidity Deviation

 

 

 

 

 

4595%RH(Refer to the image for the controllable temperature and humidity range) (No active thermal load)

±3.0%RH

 

 

 

 

5.6 Meets testing standards

GB/T2423.1-2001 Test A: Low Temperature Test Method

GB/T2423.2-2001 Test B: High Temperature Test Method

GB/T2423.3-2001Test Ca: Constant Humidity Test

GB/T2423.4-2001Test Cb: Alternating Humidity and Heat Test

GB10589-89   Low Temperature Test Chamber Technical Conditions

GB10586-89   Humidity and Heat Test Chamber Technical Conditions

GB/T11944-2012 Durable Temperature Test, Accelerated Durable Test according to GB18045

EN1279-2:2002 (E) Test Methods and Requirements for Long-Term Water Vapour Permeability

Loaded onto less than 20 pieces (510)±2)×(360±2) In the case of mm samples:

The entire process is composed of two parts:

1. 12-hour temperature cycle, total of 56 cycles (4 weeks)

2、(1176±4) A 7-week constant temperature phase, with a relative humidity of ≥95%, allowing condensation on the specimen surface.

Specific requirements for the temperature cycling phase:

Humidity requirements during the temperature cycling period: the maximum humidity should be ≥95%. No humidity control is required during the low-temperature phase of the cycle. Condensation on the sample surface is permitted.

Time intervals: t1=5h, t2=1h, t3=5h, t4=1h, t5=12h (cycle time)

Time interval deviation: Less than 1 minute

During the cycle, the temperature of the specimen placed at the center of the test box:

High-Temperature Stage: 53±1

Low Temperature Stage: -18±1

Rate of Temperature Change: 14±2℃/h

Temperature requirements for the other glass in the test chamber.

During the cycle, high-temperature phase:53±1

Low Temperature Stage: -18±2

Temperature Change: 14±2℃/h

Constant Temperature Phase: 58±0.5

The temperature of the 5 sample blocks should be continuously recorded, and humidity should be measured in the suitable area of the testing chamber and continuously recorded as well.

5.7 Temperature Curve
(As shown in the right image and should be recorded consecutively)

  

 

6、 Structural characteristics

6.1 Insulation panel cladding structure

Exterior Wall:A3Steel plate powder coating

Inner wall:SUS304Stainless Steel Sheets

Insulating Materials: Rigid Polyurethane Foam

Test box bottom plate load-bearing capacity:200kg/m2(Uniform Load)

6.2 Air Conditioning Duct

6.3 Standard Laboratory Enclosure
Configuration

Fans, heaters, evaporatorsQWDehumidifier and drainage system

Humidifiers, Dry-Overheat Preventers, Wet-Bulb Temperature Sensors

Lead Hole: Diameter Ø50mm  1Individual

6.4 Crate door

Hinge door

Door lock tightening mechanism

The box door is equipped with one double-sided conductive multi-layer hollow glass observation window, featuring a defrosting and anti-condensation device. The size of the observation window is 300 (width) × 500 (height) mm.

Door Frame Anti-Dew Electric Heater Unit

One lighting lamp is installed on the observation window of the box door.

6.5 Control Panel

Humidity Control Display, Operation Buttons, Overheat Protection Setting Device, Lighting Switch

6.6 Mechanical room

The mechanical room includes: refrigeration units, drainage and intake systems, humidity control and water supply for humidification.

6.7 Power distribution control cabinet

Cooling fan

Equipment Accumulator Timer (0-9999 hours, non-resettable)

Buzzer

Power Distribution Board

Main power leakage circuit breaker

6.8 Heater

Nickel-chromium alloy electric heating element heater

Heater Control Method: Non-contact, etc., periodic pulse width modulation, SSR (Solid State Relay)

6.9 Humidifier

Shallow Draft SteamHumidification Method

Stainless Steel CladElectricityHeater

AddWetControl Method: Non-contact, periodic pulse width modulation, SSR (Solid State Relay)

Please provide the Chinese content you would like translated.Water Level Control Device, Dry-Heat Prevention Heater Unit

7、 Cooling System

7.1 Work Method

7.2 Compressor

7.3 Cooling system control method

Air-cooled mechanical twin-screw refrigeration system

Finned Heat Exchanger (also serves as a dehumidifier)

Utilizing the "Thermoking" fully-sealed compressor from France for the air-cooled unit.

The control system automatically adjusts the operating conditions of the refrigeration unit based on test conditions and monitors its operation.

7.4 Refrigerant

7.5 Condenser

Utilize eco-friendly refrigerant R404A

Soldered PlateHeat Exchanger(Switzerland)

7.6 Cooling evaporator

Utilizing a corrugated fin refrigerant evaporator, located within the air duct sandwich at the rear of the test chamber, it is forcibly ventilated by a long shaft motor for rapid heat exchange.

7.7 Cooling accessories

 

7.8 Throttle Device

Electromagnetic valves, bypass valves, and stop valves are all equipped with Italy's "CASTEL," while the dry filters are from the U.S. "Emerson."

The PLC (Programmable Logic Controller) of the control system automatically adjusts the operating conditions of the refrigeration unit based on test conditions.

7.9 Other

All major components are of international brand products.

8、 Electrical Control System

8.1 Controller

Utilizing the original imported "TF1740" color liquid crystal touch screen human-machine interface and high-performance programmable control, it allows direct input, display, and control of temperature, featuring intelligent human-machine interaction. It can display and set parameters, program curves, working hours, heater, refrigeration unit, and fan operation status. It also has automatic running of test programs and self-tuning of PID parameters. It can automatically combine heating, refrigeration, air circulation systems, and over-temperature alarms, ensuring the high control quality of the entire temperature control system.

8.2 Monitor

7-inch 640×480 dot matrix, color LCD display

8.3 Operation Method

Program Mode, Setpoint Mode

8.4 Setting Method

Menu in Chinese, input via touchscreen. Set values and measured values displayed directly in digital format.

8.5 Program Capacity

Editable: 999 programs. Each program can have up to 999 steps, and up to 999 loop programs can be linked.

8.6 Define scope

Temperature: Adjust according to the temperature operating range of the equipment(Ceiling+5° C, Lower Limit-5)

Humidity:0100)%RH(Humidity and Temperature Test Equipment)

8.7 Display Resolution

Temperature:0.01

Time:0.1min

Humidity:0.1RH(Humidity and Temperature Test Equipment)

8.8 Input

Thermocouples (platinum resistance/voltage/current, as required by the equipment)

8.9 Communication Function

Ethernet interface with local communication capabilities.

8.10 Control Method

Anti-point saturationPID

BTHCBalanced temperature and humidity control method(Humidity and Temperature Test Equipment)

8.11 Additional Features

Fault alarm and cause, troubleshooting tips function, power failure protection function, upper and lower temperature limit protection function, timing function(Automatic start-up and automatic shut-down operation)Self-diagnostic feature.

8.12 Software Usage Environment

Windows XP or above operating system (with laptop software)

8.13 Humidity and Temperature Measurement

Temperature:PT100Type Jacketed ThermocoupleObstructed

Humidity:Electronic Moisture-Sensitive Resistor

8.14 Execute components

Schneider AC contactors, thermal overload relays, and residual current circuit breakers from France; Dahua phase sequence protectors from Wenzhou; Huajing solid-state relays and Mingda intermediate relays from Wuxi.

9、 Humidification system water supply

External Water Supply

Water Treatment Equipment

Water Storage Device

Water Storage Device Capacity

Potable Water (Supplied by User)

Water Purification Equipment

Water Tank

30Ascending

10、 Safety Protection Device

10.1 Refrigeration System

Compressor Overpressure

Compressor motor overheating

Compressor motor overcurrent

10.2 Humidification System

ElectricityHeating tube dry burn

Abnormal Water Supply(Dry)

Abnormal Drainage

10.3 TestBox

Adjustable Over-temperature Protection

10.4 Others

Total power phase sequence and phase loss protection

Leakage Protection

Short-circuit protection

 