Cyclic Immersion Corrosion Test ChamberCorrosion tests applicable to various metal materials and protective film coatings such as paint coatings. Reliable accelerated simulation of the corrosion effect on specimens in saltwater soaked, alternating wet and dry environments to evaluate the adaptability and reliability of the product, its components, and raw materials in such climatic conditions. Execution StandardsTB/T2375Specification for the periodic immersion corrosion test method of weather-resistant steel for railway use.
One,Cyclic Immersion Corrosion Test ChamberTechnical Specifications:
1Temperature Range:20℃~80℃
2Temperature fluctuation:≤±3℃
3Uniformity of temperature:≤±2℃
4Relative Humidity Range:40~98%RH
5Time Setting Range:0~9999h
II. Specifications(Unit:mm):
ModelCH-10Internal dimensionsD×W×H700×1200×800
Section 3: Control System
1Programmable with a liquid crystal touch screen display, easy to edit programs, and simple screen operation.
2Accuracy:0.1Resolution:±0.1℃Thermally sensitive sensor:PT100Platinum Resistance Thermometer.
3The function features automatic recalculation, which can immediately adjust the temperature and humidity variation conditions, ensuring more stable temperature and humidity control.
4The controller features a selectable bilingual operation interface, with real-time operation curve graphs displayed on the screen.
5The controller features an automatic screen-saver function for the display, which better protects the LCD screen during long-term operation, extending its lifespan.
6Available100Group programs, each group100Paragraphs, each paragraph can be recycled999Step capacity, set for each time segment*Large value99h59min。
7Please provide the Chinese content you would like to have translated into American English.RS-232OrRS-485Remote communication interface, allowing program design on computers, monitoring test processes, and functions for automatic power on/off.
Four: Heating System:
1Utilizes an independent system with a high-speed heating electric heater made of infrared nickel alloy.
V. Refrigeration System:
1Compressor: Fully enclosed original French Tecumseh.
2Cooling Method: Single-Unit Refrigeration.
3Cooling Method: Forced-air cooling.
4All solenoid valves, oil separators, desiccant filters, check valves, refrigerant flow windows, and accumulator tanks are equipped with imported original parts.
Section 6: Security Protection System
Overall equipment overheating, cooling system overload, cooling system overpressure, leakage, low water level, operating indicators, and automatic shutdown after fault alarms for protection.
Section 7: Equipment Usage Conditions:
1Ambient Temperature:5℃~30℃Environmental Humidity:≤85%R.H。
Free delivery to your door. Upon completion of the equipment installation and debugging, we will provide the relevant technicians with basic operation training.