Warehouse Design:
The metal design on both the inside and outside of the cabinet is rational, avoiding cold bridge design.
Note critical operation precautions in cold storage design and strictly enforce them during construction.
The refrigeration equipment layout in the design is reasonable, and the equipment capacity meets the cold storage requirements.
4. The selection of pipe diameters for each component of the refrigeration system in the design must meet the requirements of the cold storage.
5. During design, consideration should be given to the installation locations of components such as the engine, fan, expansion valve, and filter, ensuring they are easily observable and accessible for maintenance and adjustment.
6. Design should also consider aesthetics while remaining rational (such as the arrangement of conduit and piping, etc.).
Design of computer thermal control data should meet the usage requirements.
8. The design should include "protection grounding or protection zeroing for the entire system."
9. Designs must comply with * and relevant industry policy requirements, and be noted accordingly.
Warehouse Acceptance:
1. The installation of the racking should be tight, with the metal panels on the interior and exterior of the storage face not connected to prevent the formation of cold bridges.
2. Is the sealant applied between the cold storage panels even? Is the door installation level, straight, and able to close and open freely?
3. The layout of the refrigeration compressor units should be reasonable, and units of different models should be installed uniformly.
4. Are the pipe diameters of the various components in the refrigeration system in compliance with the design requirements?
5. The ease of observation and maintenance adjustment for the installation of the unit. The ease of maintenance for the fan, expansion valve, and filter installation locations.
The return air duct of the cooler fan should have a slope, and a return oil bend needs to be added at the fan outlet.
During the operation of the compressor, check the oil level, base vibration, operating sound, suction temperature, exhaust temperature, motor temperature, crankcase temperature, high and low pressure, operating current, exhaust direction, frost on the cooling fan and expansion valve, and the effectiveness of pressure protection and motor thermal overload protection.
8. Ensure that electrical control components are responsive, electrical coils should not overheat or produce hum, wire connections must be firm, and the wire sheath temperature should not exceed 40 degrees. Is the entire system equipped with a protective grounding or protective zero connection?
9. Piping for conduit and refrigeration should be installed horizontally and vertically without crossing or uneven heights. Adequate spacing should be maintained, and all piping should be securely fastened with metal clips, avoiding resonance and mutual friction.
10. Is the entire project being constructed according to design specifications? Is the project and construction environment clean and tidy?