8mm inorganic pre-coated board
Cutting of inorganic pre-painted panels
① Construction site requirementsInorganic Pre-Painted BoardDuring cutting, pneumatic or electric tools can be used for cutting processing. The cutting tool should be a fine-toothed type (for cutting stone) or a toothless type; wiring or conduit required for construction.Holes can be directly drilled using a drill bit; also, a milling cutter can be used for drilling holes, slotting, chamfering, etc.
② Due toInorganic Pre-Painted BoardsIt is an inorganic material, which may exhibit minor chipping during cutting or drilling.Edges and chamfers can be sanded with 800-grit or higher sandpaper. All exposed board bases due to processing should be coated with at least two layers of silicone waterproofing agent for waterproof treatment.
③ Due toInorganic Pre-Painted BoardThe base material is inorganic fiber-reinforced cement board, which generates dust during processing. As dust is harmful to humans, the processing site should be located as open as possible outdoors or in an area with good air circulation.Great spotTherefore, it is recommended to use cutters equipped with dust collection devices, and workers should wear masks to prevent dust.Potential hazards to human health.
④When cleaning the processing area, please sprinkle water first to prevent dust from flying, and then sweep up the dust.Seal and place in trash bags for transportation to the waste disposal station.