Utility communication cable, wiring cable_SupplyPro Co., Ltd._Shanghai Hufei Cable Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》

Shanghai Hufei Cable Co., Ltd.

Communications Cable, Cables

18917681111
021-36520111
 

Product Categories
Home > SupplyPro Co., Ltd. > Utility communication cable, wiring cable
Utility communication cable, wiring cable
品牌: Shanghai Hufei Cable Co., Ltd.
Model Specifications: Named pair count of wiring communication cable × 2 × conductor nominal diameter
Standard: YD/T 322-1996
Application Scope: For audio transmission
单价: 1.80/Root
最小起订Quantity: 1 Root
供货总Quantity: 999 Root
有效期至: 长期有效
最后更新: 2022-11-15 16:49
 
详细Info

HPVV配线电缆HJVV局用通信电缆

HPVV Wiring Cable                  HJVV Local Communication Cable

Product Features:

Model Specifications: Nominal Pair Count of Cable Communication Cable × 2 × Nominal Wire Diameter. For example, HYA 600×2×0.40. Our company mainly produces HYA communication cables in the 0.40mm and 0.50mm series with 3200 pairs and below, and can also manufacture other series cables according to customer requirements.

Standard: YD/T 322-1996 Copper-core Polyolefin Insulated Aluminum-Plastic Sheathed Indoor Communication Cable

Application Range: Designed for transmitting audio signals, analog signals up to 150 KHz, and digital signals up to 2048 Kbit/s. Under certain conditions, it can also be used for digital signals above 2048 Kbit/s. This cable is primarily used in local telecommunication lines in urban areas, typically for indoor use and pipeline laying.

Cable Usage Precautions:

The environmental temperature during cable laying and installation must not be below -5℃.

2. The bending radius of the cable during laying should not be less than 15 times the outer diameter of the cable.

3. Cable drums are only allowed to roll in a single direction over short distances; they must not be placed flat.

4. When cables enter pipes, attention should be given to minimize friction between the cable and the pipe wall. When entering manholes, the bending radius should not be less than the radius of the cable drum, and friction with the manhole edge should be avoided.

5. The cable should be filled with a certain pressure of dry gas during operation (pre-filled with 30-50 kPa of dry air prior to shipment).

6. The cable operates in an ambient temperature range of -30℃ to +60℃.


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

18917681111