Supply Electric Stop Valves J941H-16C DN400 Electric High-Temperature Steam Stop Valves, Manufacturer Direct Supply
Product Features
Product advantage
Performance Parameters Table:
Parameter Name Model | Nominal Torque N.m | Torque Control N.m | Torque Control N.m | Allow through valve rod diameter | Manual gear ratio | Output Speed: r/min | Motor Power: kW | Weight: Kg |
DZW5 | 50 | 75 | ≤25 |
28 |
1:1 |
18 | 0.12 | |
DZW10 | 100 | 150 | ≤50 | 0.18 | ||||
DZW15 | 150 | 225 | ≤75 | 0.25 | ||||
DZW20 | 200 | 300 | ≤100 | 40 | 0.37 | |||
DZW20I | 28 | |||||||
DZW30 | 300 | 450 | ≤150 | 40 | 0.55 | |||
DZW30I | 28 | |||||||
DZW45 | 450 | 675 | ≤225 |
48 | 24 | 1.1 | 100 | |
36 | 1.5 | |||||||
DZW60 | 600 | 900 | ≤300 | 24 | 1.5 | 103 | ||
36 | 2.2 | |||||||
DZW90 | 900 | 1350 | ≤450 | 60 | 24 | 2.2 | 128 | |
DZW90I | 48 | 36 | 3.0 | |||||
DZW120 | 1200 | 1800 | ≤600 | 60 | 24 | 3.0 | 132 | |
DZW120I | 48 | |||||||
DZW180 | 2500 | 3000 | ≤1250 |
70 |
25:1 | 24 | 4.0 | 245 |
36 | 5.5 | |||||||
DZW250 | 2500 | 3000 | ≤1250 | 24 | 5.5 | 250 | ||
DZW350 | 3500 | 4200 | ≤1750 | 75 | 13:1 | 18 | 7.5 | 450 |
DZW500 | 5000 | 6000 | ≤2500 | 10 | 460 |
2: Technical Conditions
Z: Integrated Type T: Adjustable Type N: Smart Type
Protection Type: W for Outdoor, B for Explosion Proof
Output Speed: Numeric, Unit: r/min (revolutions per minute)
Connection Type: T for Thrust Type, I for Power Station Type. Standard Type is indicated without a letter. Rated Torque: Number indicates, unit is kgf.m.
Product Form: Multi-revolution electric unit
Power Supply: Motor is 3-phase AC 380V, 50Hz. Control is 2-phase AC 220V, 50Hz.
Optional Power Supply: AC 220~660V, 50/60Hz (to be specified at time of order) 2: Environmental Temperature; -20℃ to +60℃; Optional: -40℃ to +70℃
3: Relative humidity; not greater than 95% (at 25°C)
4: Working Environment; Standard type for areas without flammable, explosive, and highly corrosive media; Explosion-proof type (ExdIIBT4) suitable for IIA, IIB groups T1-T4 explosive gases.
5: Protection Rating; IP65/67 (Special Order IP68)
6: Motor for duty cycle; rated running time 10 minutes. F-grade insulation.
7: Corrosion-Resistant Coating: High-Temperature Painting

Product Featuresfeatures

Three: Adjust
Adjusting torque, during travel, it is essential to check if the potentiometer on the position indicator has been disconnected (loosen the set screw on the gear of the potentiometer shaft to disconnect it) to prevent damage.
Torque control mechanism adjustment:
Firstly, adjust the torque.
(2) Start from a low torque value and gradually increase the torque until the valve is fully closed.
(3) Adjust the torque for the switch direction based on the valve's operating characteristics; typically, the open direction torque is greater than the close direction torque.
(4) Adjustments are made under conditions of no load, no medium pressure, etc. When there is pressure and temperature, attention should be given to whether it can be tightly sealed. If it cannot be sealed tightly, the torque value should be appropriately increased to ensure it can be tightly sealed and easily opened.
2. Travel control mechanism adjustment:
(1) Close the valve manually.
(2) Disengage the stroke control mechanism by using a screwdriver to push the plunger in the stroke control mechanism and rotate it 90°, thereby separating the driving pinion from the counter's unit gear set.
(3) Rotate the "Off" adjustment shaft with a screwdriver until the cam engages the spring plate, following the arrow direction until the microswitch action is achieved. This indicates the initial adjustment of the "Off" travel is complete.
(4)
At this point, you can electrically turn it a few rotations, then turn it off. Check if the closing travel meets the requirements; if not, you can adjust it again following the aforementioned procedure.
(5) Adjustment of Open Direction: After the closed direction is adjusted, manually open the valve to the desired position. Then, disengage the stroke control mechanism, rotate the "open" adjustment shaft in the direction of the arrow until the cam engages the spring plate, causing the micro-switch to activate. After that, reengage the stroke mechanism with the driving gear, indicating the completion of the open direction stroke adjustment. Once the stroke control mechanism is adjusted, it can be operated repeatedly. Generally, the open valve is controlled around 90%.
3. Adjustable Opening Indicator Adjustment:
(1) Adjust the adjustable opening indicator and remote potentiometer after tuning the torque and stroke.
Product detail imagesdetails

Su Valve brand electric device

Acid and alkali-resistant electric equipment

DZW60 Electric Unit
Corporate Strengthenterprise
Yangzhou Su Valves Control Equipment Co., Ltd. is located in the historically and culturally renowned city of Yangzhou, China. We are a professional manufacturer specializing in the research, development, and market sales of electric valve actuators. The company has established a reliable quality assurance system, ensuring the implementation of product quality standards. Our range of electric valve actuators is comprehensive, widely used in power, metallurgy, petroleum, chemical, papermaking, and water supply and drainage industries, and highly praised by customers. For many years, Yangzhou Su Valves Control Equipment Co., Ltd. has adhered to the business philosophy of "Quality, Integrity, and Customer First," earning recognition from users across various industries, building the company's brand image, and creating fine products in the electric valve industry. Our products are based in China, facing the world, and distributed in over 30 provinces, municipalities, and autonomous regions across the country. The company provides comprehensive customer service...
After-Sales Policyafter sale
About Shipment
Subject to customer's requirements
About Returns and Exchanges
Please contact us promptly if there are any issues with the product after receipt for negotiation and resolution.
Subject to customer's requirements