Supply parameters and maintenance for electric actuator drive unit DZW45-24W
Product Features
Product advantage
I: Overview
The DZW series electric actuators for valves are a new generation of products that our company has developed and refined based on our mature products. They feature compact structure, small size, attractive appearance, and stable and reliable performance. The good protection grade meets the needs of various designs: explosion-proof, all-position switching, and all-position regulating.
The DZW series is used to control the opening and closing of valves. Suitable for gate valves, stop valves, check valves, diaphragm valves, and its derivative products can be used for ball valves, butterfly valves, and air gates, etc. It can accurately respond to control commands and is an indispensable driving device for remote control, centralized control, and automatic control of valves.
This product meets the specifications of JB/T8528-1997 (Technical Conditions for Electric Actuators of General Valves) and the performance of explosion-proof types conforms to GB3836.1-2000 (Part 1 of Electrical Equipment for Explosive Gas Atmospheres: General Requirements), GB3836.2-2000 (Part 2 of Electrical Equipment for Explosive Gas Atmospheres: Explosion-Proof Type "d"), and JB/T8529-1997 (Technical Conditions for Explosion-Proof Electric Actuators).
Two: Technical Conditions
Z: Integrated Type T: Adjustable Type N: Smart Type
Protection Type: W for Outdoor, B for Explosion-Proof
Output Speed: Numeric, Unit: r/min (revolutions per minute)
Connection Type: T for Thrust Type, I for Power Station Type, Standard Type with No Code; Rated Torque: Numerical value, Unit: kgf.m
Product Form: Multi-Rotary Electric Device
Power: Motor is 3-phase AC 380V, 50Hz. Control is 2-phase AC 220V, 50Hz.
Optional Power Supply: AC 220~660V, 50/60Hz (to be specified at time of order) 2: Environmental Temperature; -20℃ to +60℃; Optional Temperature -40℃ to +70℃
3: Relative humidity; not more than 95% (at 25°C)
4: Working Environment; Standard type for areas without flammable, explosive, and highly corrosive media; Explosion-proof type (ExdIIBT4) for use in IIA, IIB groups T1-T4 explosive gases.
5: Protection Grade; IP65/67 (Special Order IP68)
6: Motor for continuous operation; rated running time 10 minutes. F-grade insulation.
7: Corrosion-resistant Coating: High-temperature Paint Coating

Product Featuresfeatures

Three: Adjust
Adjusting torque, during travel, ensure the potentiometer on the position indicator is disengaged (loosen the set screw on the gear of the potentiometer shaft) to prevent damage.
Torque control mechanism adjustment:
Firstly, adjust the torque.
(2) Begin with a low torque value and gradually increase it until the valve is fully closed.
(3) Adjust the torque for switch direction based on the valve's operating characteristics; typically, the open direction torque is greater than the close direction torque.
(4) Adjustments are made under conditions of no load, no medium pressure, etc. When there is pressure or temperature, attention should be paid to whether it can be tightly sealed. If it cannot be sealed tightly, the torque value should be appropriately increased to ensure it can be tightly sealed and easily opened.
2. Travel Control Mechanism Adjustment
(1) Close the valve manually.
(2) Disengage the stroke control mechanism by using a screwdriver to push the top rod in the stroke control mechanism and rotate it 90°, thereby separating the driven small gear from the counter's unit gear set.
(3) Rotate the "OFF" adjustment shaft with a screwdriver in the direction of the arrow until the cam presses down on the spring plate, causing the microswitch to activate. This indicates that the "OFF" stroke has been initially adjusted.
(4)
At this point, you can turn it on electrically for a few rotations, then turn it off. Check if the closing travel meets the requirements; if not, adjust it again following the above procedure.
(5) Direction Adjustment: After the valve is adjusted in the closed direction, manually open the valve to the desired position. Then, disengage the stroke control mechanism, rotate the "open" adjustment shaft in the direction of the arrow until the cam presses the spring plate, causing the microswitch to activate. Reengage the stroke mechanism with the driving gear, and the opening stroke is complete. After adjusting the stroke control mechanism, repeat the operation a few times. Generally, the valve is opened to about 90%.
3. Adjustable Opening Indicator Adjustment:
Adjust the adjustable opening indicator and remote potentiometer after tuning the gear and stroke.
Product detail imagesdetails

Soo Valve brand electric equipment

Acid and alkali-resistant electric equipment

DZW60 Electric Unit
Corporate Strengthenterprise

Yangzhou Su Valve Control Equipment Co., Ltd. is located in the historically and culturally renowned city of Yangzhou, China. It is a professional manufacturer specializing in the research, development, and marketing of electric valve actuators. The company has established a reliable quality assurance system, with product quality standards strictly implemented. Our product range of electric valve actuators is comprehensive, widely used in power, metallurgy, petrochemical, papermaking, water supply, and drainage projects, and highly praised by customers. For many years, Yangzhou Su Valve Control Equipment Co., Ltd. has adhered to the business philosophy of "Quality, Integrity, and Customer First," gaining recognition from users across various industries, establishing the company's brand image, and creating fine products in the electric valve industry. Our products are based in China and reach out to the world, serving over thirty provinces, municipalities, and autonomous regions across the country. The company provides comprehensive customer service...
After-Sales Policyafter sale
About Shipment
Subject to customer's requirements
About Returns and Exchanges
If there are any disputes upon receiving the product, please contact us promptly to negotiate a resolution.