NM-01S Manual/Semi-Automatic Thermocouple Resistance Calibration System_SupplyPro Co., Ltd._Taian Nimeng Electronic Technology Co., Ltd.

Taian Nimeng Electronic Technology Co., Ltd.

Thermocouple (single furnace, double furnace, batch furna...

18661351995
0538-8588768
 

Product Categories

Contact Information
  • Contact person:苏经理
  • Telephone:0538-8588768
  • Mobile:18661351995
  • Address:Shandong Province, Taian City, Panhe Avenue, East End of Tai Mountain District
Home > SupplyPro Co., Ltd. > NM-01S Manual/Semi-Automatic Thermocouple Resistance Calibration System
NM-01S Manual/Semi-Automatic Thermocouple Resistance Calibration System
品牌: Nimmon
Product Type 1: NM-01S Thermocouple Resistance Manual/Semi-Automatic Calibration System
Product Type 2: NM-01S Manual/Semiautomatic Thermocouple Resistance Calibration System
Product Type 3: NM-01S Manual/Semi-Automatic Thermocouple Resistance Calibration System
单价: 电议
最小起订Quantity:
供货总Quantity:
有效期至: 长期有效
最后更新: 2023-11-02 10:25
 
详细Info

Product Overview

The NM-01S Thermocouple Resistance Manual Verification System consists of a manual changeover switch, high-precision digital meter, special cable signal lines, verification furnace, intelligent precision temperature control device, water (oil) tank, standard instruments, and an ice point instrument. Users can select different constant temperature equipment and standard instruments according to the temperature range of the sensor to be verified. Equipped with a computer, communication card, and corresponding verification software, the system can automatically control the temperature of constant temperature equipment during the verification process, read digital meter values, process data, and generate and print tables, forming a semi-automatic verification system.

Manual switch for multi-channel signal switching of the inspected and standard as well as reference sensor signals, featuring a lead switching function during three-wire resistance verification.

Special cable signal lines are for manual switches and sensor connection lines, used for connecting standardizers, reference terminal compensation sensors, and tested sensors.

Thermocouple and Resistance Thermometer Calibration System Configuration Sheet (Single Furnace, Double Furnace/Group Furnace, Manual)

■ Standard Equipment

□ Indicates optional equipment

No equipment required.

 

Note: 1. The lower temperature limit of the low-temperature tank is selectable at -100°C, -80°C, -60°C, -40°C, -30°C, -10°C, and 0°C.

2. Standard gauges are selected based on the model and accuracy grade of the sensor to be inspected.

3. Optional digital multimeters: Keithley 2000/2010/2002, Agilent 34401A/34420A, etc.

4. Optional multi-channel scanners, available with 8 or 10 inspection channels

询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

18661351995