I. Product Introduction:
OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, as well as meteorological industry standard QX10.1-2002 and communication industry standard YD/T1235.1-2002. The product strictly adheres to the ISO9001 quality assurance system for quality control.
This product is widely used in power systems for mobile communication base stations, microwave communication offices/stations, telecommunication rooms, industrial factories and mines, civil aviation, etc., including various power distribution stations, power rooms, distribution panels, AC/DC distribution boards, switch boxes, and other critical equipment prone to lightning strikes.
◆ Utilizes a pressure-sensitive resistor chip for stable and reliable performance.
◆ Features a plug-and-play structure for easy replacement;
◆ Equipped with a mechanical thermal release device, offering high sensitivity.
Modular sealing design, high flow rate, and lower protection level.
◆ Single phase, can be combined into multi-pole for various grid configurations.
◆ Equipped with a degradation display window, and can be optionally fitted with a remote遥信output interface.
The housing is made of high flame-retardant materials, ensuring high safety performance.
35mm track mounting, standard modular design.
Product is available with FM alarm function option.
◆ A wide variety of colors and styles available to meet various aesthetic requirements!
◆ Product parameters are for single-module units. For three-phase, please change the model to /4. For single-phase, please change the model to /2.
ThreeTechnical Specifications:

Product Model (Single Module Parameters)
| OD-M40C/4 OD-M40C/4-FM
|
IEC Category/VDE Specification Grade/EN Type
| II/C/T2
|
Working Voltage Un (V)
| 220V
|
Continuous Operating Voltage Uc (V)
| 320V
|
Nominal Discharge Current In (KA) 8/20μs
| 20KA
|
Discharge Current Imax (KA) 8/20μs
| 40KA
|
Voltage Protection Level Up (KV)
| ≤1.5
|
Response Time (ns)
| <100
|
Backup yarn (optional)
| 63A
|
Degradation Indicator
| Degradation Indicator Window
|
Work Environment
| -40℃ to +85℃, relative humidity < 95%
|
Product Dimensions
| 18mm
|
Conductor cross-sectional area installation
| 2.5mm2-50mm2 soft wire/multi-strand copper-core wire
|
Protection Level, Compliant with IEC 60529/EN 60529
| IP20
|
Insulating Shell Material
| Flame Retardant PBT
|
|
Section 4: Product Installation Instructions
Prior to installation, power must be disconnected, and operation with power is strictly prohibited.
2. Recommend installing a fuse or an air switch in series at the front end of the lightning protection module.
3. SPD is parallel installed at the power input end of the building's distribution box or server room. The product is for track-mounted installation, and Kevin connector type can be adopted if conditions permit.
4. Please connect according to the installation diagram provided: L stands for phase wire, N for neutral wire, and PE for ground wire. Do not connect them incorrectly. After installation, close the automatic circuit breaker switch and check if the operation is normal.
5. During operation, the lightning protection module should be regularly inspected and the status of the fault display window checked. When the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and prompt repair or replacement should be carried out.
6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.
All connections must be secure and reliable electrical connections.
8. Lightning protection grounding should comply with lightning protection specifications, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.
I. Product Introduction:
OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, as well as meteorological industry standards QX10.1-2002 and telecommunications industry standards YD/T1235.1-2002. The product undergoes strict quality control in line with the ISO9001 quality assurance system.
This product is widely used in mobile communication base stations, microwave communication offices/stations, telecommunication rooms, industrial mines, civil aviation, and other power systems, such as various power distribution stations, distribution rooms, distribution cabinets, AC/DC distribution boards, switch boxes, and other critical and lightning-prone equipment.
◆ Utilizes a sensitive resistor chip for stable and reliable performance.
◆ Features a plug-and-play structure for easy replacement;
Mechanical thermal release device with high sensitivity.
◆ Modular sealing design, high flow rate, lower protection level;
Single-phase, can be combined into multi-phase for different grid configurations.
◆ Features a degradation display window and is available with a remote遥信output interface.
The housing is made of high flame-retardant materials, ensuring high safety performance.
35mm track mounting, standard modular design.
Product options include FM alarm function.
A wide variety of colors and styles to cater to all aesthetic preferences!
Product parameters are for single-module units. For three-phase, please change the model to /4. For single-phase, please change the model to /2.
ThreeTechnical Specifications:
Product Model (Single Module Parameters)
| OD-M40C/4 OD-M40C/4-FM
|
IEC Category/VDE Specification Grade/EN Type
| II/C/T2
|
Working Voltage Un (V)
| 220V
|
Continuous Operating Voltage Uc (V)
| 320V
|
Named Discharge Current In (KA) 8/20μs
| 20KA
|
Discharge Current Imax (KA) 8/20μs
| 40KA
|
Voltage Protection Level Up (KV)
| ≤1.5
|
Response Time (ns)
| <100
|
Backup yarn (optional)
| 63A
|
Degradation Indicator
| Degradation Indicator Window
|
Work Environment
| -40°C to +85°C, relative humidity < 95%
|
Product Dimensions
| 18mm
|
Conductor cross-sectional area installation
| 2.5mm2-50mm2 soft wire/multi-strand copper core wire
|
Protection rating, conforms to IEC 60529/EN 60529
| IP20
|
Insulating Shell Material
| Flame-retardant PBT
|
|
IV. Product Installation Instructions:
1. Power must be disconnected before installation, and operation with live electricity is strictly prohibited.
2. Suggest connecting a fuse or an air switch in series at the front of the lightning protection module.
3. SPD is parallel installed at the power input end of the building's distribution box or server room. The product is for track-mounted installation, and the Kelvin connection method can be adopted if conditions permit.
4. Please connect according to the installation diagram provided, where L is the phase line, N is the neutral line, and PE is the earth line. Do not connect them incorrectly. After installation, turn on the automatic circuit breaker switch and check if the operating status is normal.
5. During use, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.
6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.
All connections must be secure and reliable electrical connections.
8. Lightning protection grounding should meet the requirements of lightning protection standards, with the grounding wire as thick and short as possible, and the grounding resistance should be less than 10Ω.