品牌: Wuhan LeiChuang Lightning Protection
Installation Type: Other
Protective nature: Open-air surge arrester
Voltage Grade: Low-pressure
单价: 500.00/Piece
最小起订Quantity: 1 Piece
供货总Quantity: 10 Piece
有效期至: 长期有效
最后更新: 2023-08-29 11:31
 
详细Info

I. Product Introduction:

OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, as well as meteorological industry standard QX10.1-2002 and communication industry standard YD/T1235.1-2002. The product undergoes strict quality control under the ISO9001 quality assurance system.

This product is widely used in power systems for mobile communication base stations, microwave communication stations/offices, telecom rooms, industrial mines, and civil aviation, etc. It includes various power distribution stations, power distribution rooms, distribution cabinets, AC/DC power distribution screens, switch boxes, and other critical equipment prone to lightning strikes.

◆ Utilizes a pressure-sensitive resistor chip, offering stable and reliable performance.

◆ Utilizes a plug-and-play structure for easy replacement;

Mechanical thermal release device with high sensitivity.

Modular sealing design, high flow rate, lower protection level.

Single-phase, capable of being combined into multi-pole for use in various grid configurations.

◆ Equipped with a degradation display window, and can be equipped with a remote遥信output interface.

The housing is made of high flame-retardant material, ensuring high safety performance.

35mm track mounting, standard modular design.

◆ The product is available with an optional FM alarm feature.

◆ A wide variety of colors and styles available to meet various aesthetic requirements!

◆ Product parameters are for single-module units. For three-phase, please change the model to /4. For single-phase, please change the model to /2.

ThreeTechnical Specifications:

Product Model (Single Module Parameters)

  

  OD-M40C/4 OD-M40C/4-FM

  

IEC Category/VDE Specification Grade/EN Type

  

  II/C/T2

  

Working Voltage Un (V)

  

  220V

  

Continuous Operating Voltage Uc (V)

  

  320V

  

Named Discharge Current In (KA) 8/20μs

  

  20KA

  

Discharge Current Imax (KA) 8/20μs

  

  40KA

  

Voltage Protection Level Up (KV)

  

  ≤1.5

  

Response Time (ns)

  

  <100

  

Backup silk (optional)

  

  63A

  

Degradation Indicator

  

Degradation Indicator Window

  

Work Environment

  

-40°C to +85°C, relative humidity < 95%

  

Product Dimensions

  

  18mm

  

Conductor cross-sectional area installation

  

2.5mm2-50mm2 soft wire/multifilament copper-core wire

  

Protection Level, conforms to IEC 60529/EN 60529

  

  IP20

  

Insulating Shell Material

  

Flame-retardant PBT

  




  

Section 4: Product Installation Instructions:

Before installation, power must be disconnected, and operation with power on is strictly prohibited.

2. Recommend installing a fuse or a circuit breaker in series at the front end of the lightning protection module.

3. SPD is parallelly installed at the power input end of the building's distribution box or the server room. The product features a track-mounted installation, and a Kelvin connection type may be used under permissible conditions.

4. Please connect according to the installation diagram provided, where L is the phase wire, N is the neutral wire, and PE is the ground wire. Do not connect incorrectly. After installation, close the automatic circuit breaker switch and check if the operation is normal.

5. During operation, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.

6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.

All connections must be secure and reliable electrical connections.

8. Lightning protection grounding should comply with lightning protection specifications, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.

I. Product Introduction:

OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, and meteorological industry standards QX10.1-2002, as well as communication industry standards YD/T1235.1-2002. The product undergoes strict quality control under the ISO9001 quality assurance system.

This product is widely used in mobile communication base stations, microwave communication centers/stations, telecom rooms, industrial mines, civil aviation, and other power systems, such as various power distribution stations, power rooms, distribution panels, AC/DC distribution boards, switch boxes, and other important equipment prone to lightning strikes.

◆ Utilizes a pressure-sensitive resistor chip for stable and reliable performance.

◆ Features a plug-and-play structure for easy replacement;

Mechanical thermal release device with high sensitivity.

◆ Modular sealing design, high flow rate, lower protection level;

Single-phase, capable of being combined into multi-pole for use in various grid configurations.

◆ Equipped with a degradation display window, and can be optionally fitted with a remote遥信output interface.

The shell is made of high flame-retardant material, offering high safety performance.

35mm track installation, standard modular design.

◆ The product can be optionally equipped with FM alarm function.

◆ A wide variety of product colors and styles to meet all aesthetic requirements!

◆ Product parameters are for single-module configurations. For three-phase, please change the model to /4. For single-phase, please change the model to /2.

ThreeTechnical Specifications:

Product Model (Single Module Parameters)

  

  OD-M40C/4 OD-M40C/4-FM

  

IEC Category/VDE Specification Grade/EN Type

  

  II/C/T2

  

Working Voltage Un (V)

  

  220V

  

Continuous Operating Voltage Uc (V)

  

  320V

  

Rated Discharge Current In (KA) 8/20μs

  

  20KA

  

Discharge Current Imax (KA) 8/20μs

  

  40KA

  

Voltage Protection Level Up (KV)

  

  ≤1.5

  

Response Time (ns)

  

  <100

  

Backup yarn (optional)

  

  63A

  

Degradation Indicator

  

Degradation Indicator Window

  

Work Environment

  

-40°C to +85°C, relative humidity < 95%

  

Product Dimensions

  

  18mm

  

Conductor cross-sectional area installation

  

2.5mm2-50mm2 Soft Wire/Multi-strand Copper Core Wire

  

Protection Level, Compliant with IEC 60529/EN 60529

  

  IP20

  

Insulating Shell Material

  

Flame-retardant PBT

  




  

Section 4: Product Installation Instructions:

1. Power must be disconnected before installation, and operation with live electricity is strictly prohibited.

2. It is recommended to connect a fuse or an air circuit breaker in series at the front of the lightning protection module.

3. SPD parallel installation at the power input end of building distribution boxes or server rooms. The product is for track-mounted installation, and the Kelvin connection method can be adopted if conditions permit.

4. Please connect according to the installation diagram provided: L for phase wire, N for neutral wire, and PE for ground wire. Do not connect incorrectly. After installation, turn on the automatic circuit breaker switch and check if the operation is normal.

5. During use, the lightning protection module should be regularly inspected and the status of the fault display window checked. When the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.

6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.

All connections must be secure and reliable electrical connections.

8. Lightning protection grounding should comply with lightning protection specifications, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.