Single-phase / Three-phase Power Surge Protection Module
品牌: Wuhan LeiChuang Lightning Protection
Installation Type: Others
Protective nature: Open-air lightning arrester
Voltage Grade: Low-pressure
单价: 500.00/Piece
最小起订Quantity: 1 Piece
供货总Quantity: 10 Piece
有效期至: 长期有效
最后更新: 2023-08-29 11:30
 
详细Info

I. Product Introduction:

OrdENThe surge protection module for power supply is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, and industry standards QX10.1-2002 for meteorological and YD/T1235.1-2002 for communication, and is strictly controlled under the ISO9001 quality assurance system.

This product is widely used in power systems for mobile communication base stations, microwave communication offices/stations, telecom rooms, industrial factories and mines, civil aviation, and more. It includes various power distribution stations, rooms, cabinets, AC/DC distribution panels, switch boxes, and other critical equipment prone to lightning strikes.

◆ Utilizes a pressure-sensitive resistor chip for stable and reliable performance.

◆ Utilizes a plug-and-play structure for easy replacement;

◆ Equipped with a mechanical thermal release device, offering high sensitivity in operation.

Modular sealing design, high flow rate, lower protection level.

◆ Single phase, capable of being combined into multi-pole for various grid configurations.

◆ Equipped with a degradation display window and can be optionally fitted with a remote remote signal output interface.

The housing is made of high flame-retardant materials, ensuring high safety performance.

35mm track mounting, standard modular design.

◆ The product is available with an optional FM alarm feature.

◆ A wide variety of colors and styles available to meet various aesthetic requirements!

◆ Product parameters are for single module. For three-phase, please change the model to /4. For single-phase, please change the model to /2.

ThreeTechnical specifications:

Product Model (Single Module Parameters)

  

  OD-M40C/4 OD-M40C/4-FM

  

IEC Category/VDE Specification Grade/EN Type

  

  II/C/T2

  

Working Voltage Un (V)

  

  220V

  

Continuous Operating Voltage Uc (V)

  

  320V

  

Rated Discharge Current In (KA) 8/20μs

  

  20KA

  

Discharge Current Imax (KA) 8/20μs

  

  40KA

  

Voltage Protection Level Up (KV)

  

  ≤1.5

  

Response Time (ns)

  

  <100

  

Backup yarn (optional)

  

  63A

  

Degradation Indicator

  

Degradation Indicator Window

  

Work Environment

  

-40℃ to +85℃, relative humidity < 95%

  

Product Dimensions

  

  18mm

  

Conductor cross-sectional area installation

  

2.5mm2-50mm2 Soft Wire/Multi-strand Copper Core Wire

  

Protection Level, Compliant with IEC 60529/EN 60529

  

  IP20

  

Insulating Shell Material

  

Flame-retardant PBT

  




  

Section 4: Product Installation Instructions:

Before installation, the power must be disconnected, and operation with live electricity is strictly prohibited.

2. Suggest installing a fuse or a circuit breaker in series at the front end of the lightning protection module.

3. SPD is paralleled installed at the power input end of the building's distribution box or server room. The product is for track-mounted installation, and the Kelvin connection type can be adopted if conditions permit.

4. Please connect according to the installation diagram provided: L for phase line, N for neutral line, and PE for ground line; do not connect incorrectly. After installation, turn on the automatic circuit breaker switch and check if the working status is normal.

5. During operation, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window is red or if an alarm signal is output from the remote signal terminal, it indicates a fault in the lightning protection module, and prompt repair or replacement should be conducted.

6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.

All connections must be secure and reliable electrical connections.

8. Lightning protection grounding should meet the lightning protection specifications, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.

I. Product Introduction:

OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, and meteorological industry standards QX10.1-2002 and communication industry standards YD/T1235.1-2002. The product undergoes strict quality control under the ISO9001 quality assurance system.

This product is widely used in mobile communication base stations, microwave communication stations/offices, telecommunications rooms, industrial factories and mines, civil aviation, etc., for power systems such as various power distribution stations, rooms, cabinets, AC/DC distribution panels, switch boxes, and other crucial equipment prone to lightning strikes.

◆ Utilizing a pressure-sensitive resistor chip for stable and reliable performance.

◆ Features a plug-and-play structure for easy replacement;

Mechanical thermal release mechanism with high sensitivity.

◆ Modular sealing design, high flow rate, lower protection level;

◆ Single-phase, capable of being combined into multi-pole for use in various grid configurations.

◆ Equipped with a degradation display window and can be fitted with a remote遥信output interface.

The housing is made of high flame-retardant materials, offering high safety performance.

35mm track installation, standard modular design.

Product is available with optional FM alarm feature.

A wide variety of product colors and styles, catering to various aesthetic requirements!

◆ Product parameters are for single-module configurations. For three-phase, please change the model to /4. For single-phase, please change the model to /2.

ThreeTechnical Specifications:

Product Model (Single Module Parameters)

  

  OD-M40C/4 OD-M40C/4-FM

  

IEC Category/VDE Specification Grade/EN Type

  

  II/C/T2

  

Working Voltage Un (V)

  

  220V

  

Continuous Operating Voltage Uc (V)

  

  320V

  

Named Discharge Current In (KA) 8/20μs

  

  20KA

  

Discharge Current Imax (KA) 8/20μs

  

  40KA

  

Voltage Protection Level Up (KV)

  

  ≤1.5

  

Response Time (ns)

  

  <100

  

Backup yarn (optional)

  

  63A

  

Degradation Indicator

  

Degradation Indicator Window

  

Work Environment

  

-40℃ to +85℃, relative humidity < 95%

  

Product Dimensions

  

  18mm

  

Conductor cross-sectional area installation

  

2.5mm2-50mm2 soft wire/multi-strand copper-core wire

  

Protection Level, conforms to IEC 60529/EN 60529

  

  IP20

  

Insulating Shell Material

  

Flame-retardant PBT

  




  

IV. Product Installation Instructions:

Prior to installation, power must be disconnected, and operation with power is strictly prohibited.

2. Recommend connecting a fuse or an air switch in series at the front of the lightning protection module.

3. SPD is parallelly installed at the power input end of the building's distribution box or in the server room. The product is for rail-mounted installation, and the Kelvin connection method may be adopted under permissible conditions.

4. Please connect according to the installation diagram provided, with L representing the phase wire, N the neutral wire, and PE the ground wire; do not connect incorrectly. After installation, close the automatic circuit breaker switch and check if the operating status is normal.

5. During operation, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.

6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.

All connections must be secure and reliable electrical connections.

8. Lightning protection grounding should comply with lightning protection specifications, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.