I. Product Introduction:
OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, as well as meteorological industry standard QX10.1-2002 and telecommunications industry standard YD/T1235.1-2002. The product is strictly controlled under the ISO9001 quality assurance system.
This product is widely used in power systems for mobile communication base stations, microwave communication stations, telecommunication rooms, industrial mines, and civil aviation, etc., such as various power distribution stations, distribution rooms, switchboards, AC/DC power distribution panels, switch boxes, and other critical equipment prone to lightning strikes.
◆ Utilizes a pressure-sensitive resistor chip for stable and reliable performance.
◆ Utilizes a plug-and-play structure for easy replacement;
Mechanical thermal release device with high sensitivity.
Modular sealing design, high flow rate, and lower protection level.
Single phase, capable of being combined into multi-phase for use in different grid configurations.
◆ Features a degradation display window, and can be equipped with a remote remote signal output interface.
The shell is made of high flame-retardant material, ensuring high safety performance.
35mm track mounting, standard modular design.
◆ The product can be optionally equipped with FM alarm function.
A wide variety of colors and styles available to meet all aesthetic requirements!
◆ Product parameters are for single-module configurations. For three-phase, please change the model to /4. For single-phase, please change the model to /2.
ThreeTechnical Specifications:
Product Model (Single Module Parameters)
| OD-M40C/4 OD-M40C/4-FM
|
IEC Category/VDE Specification Grade/EN Type
| II/C/T2
|
Working Voltage Un (V)
| 220V
|
Continuous Operating Voltage Uc (V)
| 320V
|
Nominal Discharge Current In (KA) 8/20μs
| 20KA
|
Discharge Current Imax (KA) 8/20μs
| 40KA
|
Voltage Protection Level Up (KV)
| ≤1.5
|
Response Time (ns)
| <100
|
Backup yarn (optional)
| 63A
|
Degradation Indicator
| Degradation Indication Window
|
Work Environment
| -40℃ to +85℃, relative humidity < 95%
|
Product Dimensions
| 18mm
|
Installation Wire Cross-sectional Area
| 2.5mm2-50mm2 soft wire/multi-strand copper-core wire
|
Ingress Protection Rating, conforms to IEC 60529/EN 60529
| IP20
|
Insulating Shell Material
| Flame-retardant PBT
|
|
IV. Product Installation Instructions:
1. Power must be disconnected before installation, and live operations are strictly prohibited.
2. Suggest connecting a fuse or an air switch in series at the front of the lightning protection module.
3. SPD is paralleled installed at the power entry end of building's distribution box or机房, featuring track-mounted installation. Kevin connector type may be adopted under permissible conditions.
4. Please connect according to the installation diagram provided, with L representing the phase wire, N the neutral wire, and PE the ground wire; do not connect incorrectly. After installation, turn on the automatic circuit breaker switch and check if the operating status is normal.
5. During operation, the lightning protection module should be regularly inspected and the status of the fault display window checked. If the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and prompt maintenance or replacement should be carried out.
6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.
All connections must be secure and reliable electrical connections.
8. Lightning protection grounding should comply with lightning protection regulations, with grounding wires as thick and short as possible, and the grounding resistance should be less than 10Ω.
I. Product Introduction:
OrdENThe surge protection module is designed, manufactured, and tested in accordance with international standards IEC61643, national standards GB18802.1, and industry standards QX10.1-2002 for meteorology and YD/T1235.1-2002 for communication. The product undergoes strict quality control under the ISO9001 quality assurance system.
This product is widely used in mobile communication base stations, microwave communication offices/stations, telecommunication rooms, industrial factories and mines, and civil aviation power systems, such as various power distribution stations, power rooms, switchboards, AC/DC power distribution screens, switch boxes, and other critical equipment prone to lightning strikes.
◆ Utilizes a sensitive resistor chip for stable and reliable performance.
◆ Features a plug-and-play structure for easy replacement;
◆ Equipped with a mechanical thermal release device, with high sensitivity to motion.
◆ Modular sealing design, high flow rate, lower protection level;
◆ Single-phase, capable of being combined into multi-pole for use in various grid configurations.
◆ Equipped with a degradation display window, and can be equipped with a remote遥信output interface.
The shell is made of high flame-retardant materials, ensuring high safety performance.
◆ 35mm track mounting, standard modular design.
◆ The product is available with an optional FM alarm feature.
A wide variety of colors and styles available to meet all aesthetic requirements!
◆ Product parameters are for single-module units. For three-phase, please change the model to /4. For single-phase, please change the model to /2.
ThreeTechnical specifications:
Product Model (Single Module Parameters)
| OD-M40C/4 OD-M40C/4-FM
|
IEC Category/VDE Specification Grade/EN Type
| II/C/T2
|
Working Voltage Un (V)
| 220V
|
Continuous Operating Voltage Uc (V)
| 320V
|
Rated Discharge Current In (KA) 8/20μs
| 20KA
|
Discharge Current Imax (KA) 8/20μs
| 40KA
|
Voltage Protection Level Up (KV)
| ≤1.5
|
Response Time (ns)
| <100
|
Backup yarn (optional)
| 63A
|
Degradation Indicator
| Degradation Indicator Window
|
Work Environment
| -40°C to +85°C, relative humidity < 95%
|
Product Dimensions
| 18mm
|
Conductor cross-sectional area installation
| 2.5mm2-50mm2 soft wire/multi-strand copper-core wire
|
Protection Level, conforms to IEC 60529/EN 60529
| IP20
|
Insulating Shell Material
| Flame-retardant PBT
|
|
IV. Product Installation Instructions:

1. Power must be disconnected before installation, and operation with live electricity is strictly prohibited.
2. Suggest installing a fuse or a circuit breaker in series at the front end of the lightning protection module.
3. SPD parallel installation at the power input end of building distribution boxes or server rooms. The product is for track-mounted installation, and the Kelvin connection method can be adopted if conditions permit.
4. Please connect according to the installation diagram provided, with L representing the phase wire, N the neutral wire, and PE the ground wire. Do not connect incorrectly. After installation, close the automatic circuit breaker switch and check if the operating status is normal.
5. During operation, the lightning protection module should be regularly inspected and the status of the fault display window checked. When the fault display window shows red or the remote signal terminal outputs an alarm signal, it indicates a fault in the lightning protection module, and it should be repaired or replaced promptly.
6. Suitable for indoor operation; if installed outdoors, a waterproof housing must be added.
All connections must be secure and reliable electrical connections.
8. Lightning protection grounding must comply with lightning protection specifications, with the grounding wire being as thick and short as possible, and the grounding resistance should be less than 10Ω.