Pressure gauge shows no indication.
Reason: 1. The cut-off valve on the pressure relief pipe was not open.
2. Pressure guide pipe blockage.
3. Excessive accumulation of dirt inside the spring tube joint, causing blockage.
4. Spring tube cracked; 5. Central tooth and fan tooth wear excessively, rendering them unable to mesh.
The pointer jitters significantly.
Reason: 1. High pressure of the medium being tested.
2. The pressure gauge is installed in a location with significant vibration.
The pressure gauge pointer exhibits erratic or sluggish movements.
Reason: 1. Pointer contact with surface glass or scale causes friction.
2. Center gear shaft is bent.
3. Two gears are meshing with debris.
Issue 4: The sliding screw between the connecting rod and the fan gear is not smooth.
After the pressure is removed, the pointer cannot return to the zero point.
Reason: 1. Bent pointer; 2. Insufficient mainspring force; 3. Loose pointer; 4. Friction on the drive gears.
Five: Uneven pressure indication error.
Reason: 1. Spring tube deformation and failure.
2. The spring tube free end and sector gear, as well as the connecting rod transmission ratio, are improperly adjusted.
Six: Misaligned传动ratio.
Seven: Indication is low.
Reasons: 1. Misaligned gear ratio; 2. Leaks in the spring tube; 3. Friction in the pointer or transmission mechanism; 4. Leaks in the pressure line.
The pointer cannot reach the upper scale marking.
Reasons: 1. Small transmission ratio; 2. Incorrect positioning of the movement core in the base; 3. Improper welding location of the spring tube.