Qimiao Technology TF Series 1400°C Tube Furnace Manufacturer

产品Price 1999.00/Tai

最小起订Quantity:1 Tai 供货总Quantity: 9999 Tai

用手机扫描二维码直达商品手机版
MobileView details
Location:
Shanghai
有效期至:
长期有效
最后更新:
2022-07-15 09:04
Product Details

Model

Outer Diameter/Inner Diameter * Tube Length (mm)

φ50/44*1000

Appearance

1000 x 420 x 520

Introduction

Operating Temperature Range:300~1100℃    Temperature Control Accuracy:±1℃      Pipe Diameter:φ25~φ100

Offer an experimental environment with vacuum, controlled atmosphere, and high temperature, applicable in semiconductor, nanotechnology, fiber and other fields; highly scalable, can be combined with various interfaces, vacuum systems, and other accessories to form experimental platforms for different purposes, serving as both basic and core components.

Key Features:

●The double-layer sheet metal room exhaust fan effectively keeps the surface temperature of the furnace below 50℃.

● Automatic power-off when the lid is opened, over-temperature protection, and leakage protection to ensure safety of use

●Programmable temperature control system, capable of planning multiple curves, and programming 30 stages of temperature control

● The circuit employs a continuous heating output method, with dual-circuit power supply and separate wiring for strong and weak currents, enhancing the system's stability.

● The heating module adjusts the output power with a DC signal, thus avoiding interference from inductive electricity to the control signal.

Operational buttons are selected as low-voltage metal buttons, featuring built-in status indicator lights for safe and intuitive operation.

Safety:

● Over-raise alarm, menu lock, over-raise prevention, power recovery delay.

Service & SupportPre-sales consultation

1. Provide selection services based on the customer's technical requirements.

2. Provide recommended services based on the customer's experimental objectives.

3. In case the customer is unable to provide the requirements, we can offer the following services to our clients:Schedule experimental serviceTry before you buy.

In-transit Service

1. Offer real-time production progress reporting to clients.

2. Shipment Tracking Service

3. Establish equipment files with traceable identity numbers, recording their production process, materials, accessories, and other information.

After-sales service

1. Installation and operation instructions;

2. Optional on-site services available.

3. Parts Supply Service

Warranty Service

Electric furnace comes with a 1-year warranty and lifetime technical support and maintenance services.

*Special Notice:

1. The heating element is not covered under warranty.(Click here to learn about the features of various furnace heating element replacements)

2. Quartz accessories, sample crucibles, and other fragile parts are not covered under warranty.

3、Damage caused by corrosive gases and acidic gases is not covered under the warranty.

Pipe Furnace Precautions

The pressure inside the furnace tube must not exceed 0.02 MPa.

2. When introducing gas into the furnace tube using gas cylinders,To ensure safety,Bottles must be equipped with a pressure-reducing valve, and it is recommended to use one with a pressure below 0.02 MPa.

3、When the furnace tube is made of quartz tube, the internal temperature of the furnace is higher than1000℃At that time, the furnace tube must not be in a vacuum state; the pressure inside the furnace tube should be comparable to atmospheric pressure.

4、The gas flow into the furnace tube must be less than200SCCMTo avoid the impact of cold air currents on the hot furnace tubes.

5、For sample heating experiments, it is not recommended to close the exhaust and intake valves at the furnace tube flange end. If it is necessary to close the gas valves for sample heating, constant attention must be paid to the pressure gauge reading. If the pressure gauge reading exceeds0.02MPaIt is imperative to immediately open the exhaust valve to prevent any accidents (such as pipe破裂, flange ejection, etc.).


Regardless of whether the content on this page provides sufficient selection information for you, we still welcome you to contact your sales consultant at any time for professional consulting services.

You can also find information about electric furnaces required in various industries on our site, such as: dental, plastic color masterbatch, medical implants, metal heat treatment, ultra-hard cutting tools, graphene, and more. Your sales consultant will match you with the relevant vacuum and atmosphere equipment information.


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
18621719332

Back to Top