Product Details
One.Preface
The deaerator is a special type of low-temperature thermal deaerator.
During the boiler feedwater treatment process, deoxygenation is a very critical step. Oxygen is the primary corrosive substance in the feedwater system and boiler. Oxygen in the feedwater must be removed quickly; otherwise, it will corrode the boiler's feedwater system and components. Corrosion leads to the formation of ferric oxide, which enters the boiler, settles or adheres to the boiler tube walls and heating surfaces, creating difficult-to-dissolve iron scale that impairs heat transfer. Moreover, corrosion can cause pitting on the inner walls of the pipes, increasing the resistance coefficient. Severe pipe corrosion can even lead to pipeline accidents. The national regulations stipulate that the evaporation capacity is greater than or equal to2Steam boilers with a capacity of more than or equal to tons per hour and water temperature95℃All our hot water boilers are deoxygenated. For many years, numerous boiler water treatments have been seeking a cost-effective deoxygenation method for normal temperature water. Lianyungang Jiu Sheng Electric Power Auxiliary Machinery Co., Ltd. has many years of experience in designing and manufacturing deoxygenators.JSNCYType Series Integrated Oxygen Remover(Also known as the new integrated oxygen scavenger or integrated spray type oxygen scavenger)Utilizing advanced design schemes and manufacturing processes, our deaerators offer numerous advantages over conventional industry standards. Several domestic companies, both established and under construction, have adopted our built-in deaerator technology, with all operational enterprises achieving excellent performance results.
Two.Deoxygenator working principle
The deaerator generally includes two working processes.:
1.One-time Deaeration: Water not deaerated enters the deaeration pipeline through the inlet, and is ejected as a mist through nozzles. The mist falls and passes through a liquid-vapor mesh, where it is thoroughly mixed with steam entering through the steam inlet. This process allows the mist to reach the deaeration temperature, causing most of the oxygen in the water to be extracted and expelled through the exhaust port, thus completing the one-time deaeration.
2.Deaeration: The purpose of secondary deaeration is to ensure the tank's temperature is consistently maintained at the deaeration temperature to maximize the deaeration effect. This is achieved by heating the water that has already been deaerated through the auxiliary heating port at the bottom, causing any oxygen that was not precipitated during the primary deaeration to fully precipitate, significantly reducing the oxygen content in the water. At this point, the secondary deaeration is complete.
Three.Internal oxygen removal unit structure
JSNCYThe Type Series Internal Oxygen Remover consists of components such as an air-water mixed heating element, tank, soft water inlet coil, secondary heating and reboiling tube, insulation board, cavitation prevention device, level gauge, thermometer, automatic overflow tank, safety valve, and electric valve, as shown in the figure.
Four.Internal oxygen scavenger advantages
1.Steam and liquid mix instantly and evenly, rapid heating, high thermal efficiency,Energy-saving.
2.Carbonated beverage mixed heating steam pressure below,Suitable for use above the pressure of the heated liquid.,And the steam pressure must be higher than the liquid pressure0.05~0.1MpaLimitations.
3.JSNCYThe type built-in oxygen remover has minimal vibration and low noise.
4.JSNCYCompact type integrated deaerator, Low investment.
5.JSNCYType built-in oxygen removal device, large temperature rise,Available100℃Above.
6.JSNCYType built-in deaerator has a simple structure, is resistant to scaling, requires no maintenance, and boasts a long service life.
7.Hot water can be produced using low-pressure exhaust steam as a heat source, saving energy and protecting the environment.
8.Due to the selection of models based on user parameters or custom design, the product offers excellent suitability for users, operates smoothly, and meets all user requirements.
Five.Inbuilt Oxygen Remover Selection
Please provide the following information when placing an order:
1.Deaerator rated output
2.Water Tank Effective Volume
3.Work pressure
4.Operating Temperature
5.Inlet Water Temperature