EVSA-2000-25KW-GEU-A Three-Standard Communication Charging Pile Tester_SupplyPro Co., Ltd._Shenzhen JinChuHan Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Shenzhen JinChuHan Technology Co., Ltd.

Charging Station Test System, Charging Station Test Equipment, RCD Load, RLC ...

Consultation Hotline
13414890743

Product Categories
Home > SupplyPro Co., Ltd. > EVSA-2000-25KW-GEU-A Three-Standard Communication Charging Pile Tester
EVSA-2000-25KW-GEU-A Three-Standard Communication Charging Pile Tester
品牌: Jin Chuhuan
Load Model:
Load Characteristics: Resistive
Rated Input Voltage: AC 220V Single Phase, AC 400V Three Phase
单价: 电议
最小起订Quantity: 10 Tai
供货总Quantity:
有效期至: 长期有效
最后更新: 2022-12-20 15:16
 
详细Info


Product Overview
The Jinchu Han EVSA-2000-25KW-GEU-A AC Charging Station Tester can simulate normal and fault conditions of electric vehicles. It is equipped with built-in AC station interface testing and power sections. This product offers a standalone method for R&D engineers, testing departments, manufacturers, on-site installation, debugging, and maintenance personnel to diagnose, inspect, and verify the functionality of AC charging products, as well as their compliance with relevant standards.
Reference Standards
1. QGDW 1591-2014 Technical Specification for Inspection of Non-vehicle Electric Vehicle Charging Equipment
2. GB 19212.1-2008 Safety of power supplies, reactors, and similar products — Part 1: General requirements
3. GB/T 14048.1-2000 General Rules for Low-Voltage Switchgear and Control Gear
4. GB 5226.1-2002 Mechanical Safety - Part 1 of Electrical Equipment for Mechanical Systems: General Technical Conditions
5. GJB 235-87 General Technical Conditions for Industrial and Medium Frequency Mobile Loads
6. GB/T 18487.1 Electric Vehicle Conductive Charging System - Part 1: General Requirements
7. GB/T 20234.2 Electric Vehicle Conductive Charging Equipment Part 2: AC Charging Interface
8. GB/T 34657.1 - Part 1 of the Interoperability Test Specification for Conductive Charging of Electric Vehicles
9. SAE J1772 Conductive Charging Interface for Electric Vehicles and Plug-in Hybrid Electric Vehicles

Technical Specifications

Technical Specifications

Load Model

JCH-EVSA-2000-25KW-GEU-A

Load characteristics

Resistive

Rated Input Voltage

AC220V single-phase, AC400V three-phase

Rated Input Power

Three-phase 25KW

Rated Input Current

Single Phase 38A (National Standard)

Current

1~38A

Utilize power

National and European standards use a three-phase four-wire system, with a total three-phase power of up to 25KW. During American standard testing, one phase can be used in parallel, with a current reaching 76A.

Power Factor

PF=1

Load Accuracy

±5%

Explicit Method

Equipped with a multi-functional display meter, it shows real-time voltage, current, power, and other electrical parameters for each phase.

Display Accuracy

0.5%

Work Power Supply

AC220V/50HZ

Load Control Method

Local manual control

Test Instrument Control Display Interface

7-inch touchscreen

Insulation Grade

F Grade

IP rating

IP20 (suitable for indoor use)

Fan noise

≤75 dB

Cooling Method

Forced air-cooling

Work Method

Can operate continuously

Input Method

Communication Gun Socket (GB Standard Three-Phase Gun Socket, EN Standard Three-Phase Gun Socket, US Standard Single-Phase Gun Socket)

Manual terminal testing

Exposing L1/L2/L3/N/PE/CC/CP terminal blocks for easy manual testing

S2 Switch

Configure signal resistor switch and connect to gun socket.

CP Control Switch

Individual CP on/off control switch configuration

R2/R3 resistors

R2/R3 configuration resistor card, adjustable resistance setting on the touchscreen

Protection Features

Over-temperature Protection, Emergency Stop Protection, Grounding Protection, Buzzer Alert

Applicable Environmental Temperature

-10℃~+50℃

Mode of Transport

Equipped with swivel casters that support up to 10,000 lbs, for easy movement.

Design Dimensions

≤ 550mm (W) x 700mm (D) x 1092mm (H)

Relative Humidity Applicable

≤95%

Altitude

≤2,500 meters

Power frequency withstand voltage

2000V (1 min), no puncturing or arcing phenomena


Features
Physical Verification of Communication Charging Interface Structure
  1. Verification of communication charging interface structure and dimensions.

  2. Communication Charging Interface Insertion and Extraction Force Test

  3. Verification of communication charging interface locking mechanism function.

Electrical performance verification of the communication charging interface

  1. Normal charging test;

  2. Monitor AC charging interface phase voltage, current, energy, power factor, and other parameters.

  3. Communication Charging Interface Control Guidance Verification

  4. Test control confirmation signal CP.

  5. Duty Cycle, Voltage, Frequency

  6. The charging station allows for high current charging, etc.

  7. Test charging connection to confirm CC, immediate resistance and status confirmation.

  8. Charge completion test

Abnormal Simulation Verification of Communication Pile

  1. Overload, capable of 120% overload.

  2. S2Disconnection Test

  3. Leakage Current Test

Interoperability Testing

  1. A11001 Connection confirmation test

  2. A13001 Charge Preparation Ready Test

  3. A14001 Startup and charging phase testing

  4. A15001 Normal charging completed; test finished.

  5. A13501 CC Disconnection Test

  6. A13502 Continuous Power Failure Test

  7. A13503 CP Grounding Test

  8. A14501 Test for loss of connectivity of grounding conductor connections.

  9. A14502 Output Overcurrent Test

  10. A14503 Disconnect switch S2 for testing.

  11. A16002 CP circuit voltage limit test


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

13414890743