JCH-6KW-AC230V-RCD 6KWRCD Load
I. Product Overview
JCH-6KW-AC230V-RCD with built-in resistive and capacitive loads. An indispensable device for UPS, inverter, and IDC data center testing. This product has a full load power of 8.5KVA, features over-temperature protection, automatically disconnecting the connection at high temperatures for high reliability. Suitable for linear and nonlinear load testing of power electronic products.
Section II: Reference Standards and Regulations
QC/T 895-2011 Conductive On-board Charger for Electric Vehicles
2. QGDW 1591-2014 Technical Specification for Non-Portable Charging Equipment for Electric Vehicles
3. YD/T 1095-2000 Communication Uninterruptible Power Supply (UPS)
4. GB 19212.1-2008 Safety Part 1: General Requirements for Power Supplies, Reactors, and Similar Products
5. GB/T 14048.1-2000 General Rules for Low-Voltage Switchgear and Control Equipment
6. Marine Diesel Generator Set - GB/T 13032-2010
7. GB 5226.1-2002 Safety of Machinery - Part 1: Electrical equipment - General technical requirements
8. GJB 235-87 General Technical Conditions for Industrial and Medium Frequency Mobile Load
Section 3: Technical Specifications
Equipment Technical Specifications | |
Model | JCH-6KW-AC230V-RCD |
Load Type | RCDLoaded / R loaded |
Rated Input Voltage | 230VAC |
Rated R power | 6000W(AC230V,PF=1.0) |
Apparent Power | 8.5KVA(AC230V,PF=0.7) |
Type of Load | RSR, C individually loaded |
RCDLoad down PF value | 0.7 |
Power Factor Correction | 0.6~0.8Adjustable |
Loading method | Multi-level stepwise |
Gear position | 7RS+7, R Load+7, C Load+7 |
RSLoading position | RS1 RS2 RS3 RS4 RS5 RS6 RS7 |
RLoading position | 100W/200W/200W/500W/1KW/2KW/2KW(AC230V,PF=1.0) |
RCDGear Level | 170VA/350VA/350VA/850VA/1.7KVA/3.4KVA/3.4KVA(AC230V,PF=0.7) |
Load Accuracy | ±5% |
RPower Rating Adjustment Range | 0~6000W |
RCDAdjustable Load Power Range | 0~8.5KVA |
Control Method | Circuit Breaker |
Total Load Instant Injection | Available |
Total Load Method | Ship-shaped switch + contactor |
Load Stress Control | N/A |
Input Display | LEDDisplay, Voltage, Current, Active Power/PF |
Protection Method | Over-temperature auto-disconnect, power failure auto-disconnect |
Alarm Method | No content provided. |
Load Input | Anderson Connector |
Work Power Supply | AC: 220V/50Hz |
Power Input Method | 10ASocket |
Operation surface | Top |
Resistor Type | Stainless Steel Power Resistors |
Insulation Grade | FGrade |
Protection Level | IP20 |
Fan Noise | 75Decibels |
Cooling Method | Air-cooled |
Work Method | Continuous operation |
Protective Function | Over-temperature |
External Dimensions | Approx. 544*544*710mm (for reference only) |
Applicable Environmental Temperature | -20℃ ~ 50℃ |
Mode of Transport | caster mobility |
Relative humidity applicable | ≤95% |
Altitude | ≤ 4,000 meters |