RCD Load JCH-100KW-AC400V-RCD_SupplyPro Co., Ltd._Shenzhen JinChuHan Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Shenzhen JinChuHan Technology Co., Ltd.

Charging Station Test System, Charging Station Test Equipment, RCD Load, RLC ...

Consultation Hotline
13414890743

Product Categories
Home > SupplyPro Co., Ltd. > RCD Load JCH-100KW-AC400V-RCD
RCD Load JCH-100KW-AC400V-RCD
品牌: Jin Chuhuan
Brand:
Load Type: Communication Load
Load Model: JCH-100KW-AC400-RCD
单价: 电议
最小起订Quantity: 5 Tai
供货总Quantity:
有效期至: 长期有效
最后更新: 2022-12-22 14:26
 
详细Info


JCH-100KW-AC400V-RCD 100KW RCD Load

 

I. Product Overview

Jin ChuhanCommunication NonlinearityBuilt-in resistive and capacitive loadsIsUPSInverterVariable Frequency Drives and AC Variable Frequency Power SuppliesEssential testing equipment. This product is suitable for load testing and aging testing of electrical electronic products.

II. Reference Standards

QC/T 895-2011 Conductive On-board Charger for Electric Vehicles

2. YD/T1095-2008 Uninterruptible Power Supply (UPS) for Telecommunication Use

3. GB 19212.1-2008 Part 1: Safety of Power Supplies, Reactors, and Similar Products - General Requirements

4. General Rules for Low-Voltage Switching and Control Equipment, GB/T 14048.1-2000

5. Marine Diesel Generator Set, GB/T 13032-2010

6. GB 5226.1-2002 Mechanical Safety - Part 1 of Mechanical Electrical Equipment: General Technical Conditions

7. GJB 235-87 General Technical Conditions for Industrial and Medium Frequency Mobile Load

Section 3: Technical Specifications

Equipment Technical Specifications

Name

Communication Load

Model

JCH-100KW-AC400-RCD

Rated Voltage

AC400V(L-N:AC230V)

Rated Power

100KW(PF=1.0),100KVA(0.8≦PF<1.0)

Power Factor

PF:0.8~1.0

Ratio of Volume: W:UF

1:2

Power Rating

Three-phase independent:

RPhase: Total of 10 steps, each step 3.3KW, fine step 3.3KW (PF=1.0)

SStep: Total of 10 steps, each step 3.3KW, fine step of 3.3KW (PF=1.0)

TPhase: Total of 10 steps, each step 3.3KW, fine step 3.3KW (PF=1.0)

During three-phase synchronization:

10 steps, each step 10KW, fine step 10KW (PF=1.0)

Loading resolution

Step Increment: 10KW

Load Accuracy

±5%

Work Power Supply

Three-phase power supply

Wiring method

Anderson Terminal U V W N PE

Control Method

Local Circuit Breaker

Explicit method

N/A

Protection Grade

IP20(Indoor use suitable

Fan Noise

75Decibel

Cooling Method

Forced Air Cooling: Left intake, right exhaust.

Work Method

Continuous operation

Protective Function

Overcurrent protection

External Dimensions:Width x Depth x Height

Approx. Load Host Size: 800*W x 750*D x 1800*H mm (for reference only)

Applicable Environmental Temperature

-10℃~+50℃

Mode of Transportation

2 front swivel casters, 2 rear swivel casters.

Relative Humidity Applicable

≤95%

Altitude

≤2,500 meters


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

13414890743