详情描述

Instrument Introduction:

The GC-9890BD transformer oil gas chromatograph is a multipurpose gas chromatograph designed in accordance with the power department's standards, widely incorporating the advantages of similar instruments from both domestic and international markets. The instrument features a dual-column parallel分流柱 system, equipped with a thermal conductivity detector, a dual-hydrogen flame detector, and a conversion furnace.

The instrument allows for a comprehensive analysis of dissolved gas components in oil in a single sampling. Primarily applied in the internal fault detection of oil-filled electrical equipment in power systems, the instrument is multi-functional and can be used for analyzing cooling media in hydrogen-cooled generators and flue gas analysis from boilers.And environmental detection and analysis. Additionally, it is widely used in gas analysis for systems such as oil, chemical, and mining industries.


Technical Specifications:

Key Technical Specifications:

Column Room Temperature: Room temperature +5℃ to 400℃, temperature control accuracy ±0.05℃

2. Test Room Temperature: Room temperature +15℃~400℃, temperature control accuracy ±0.05℃

3. Furnace Temperature: Room temperature +15℃ to 360℃, temperature control accuracy ±0.1℃

4. TCD sensitivity, low detection concentration for H2 < 5ppm

5. FID Detection Limit

The Zen detection concentration for C2H2 is less than 0.1ppm; for CO and CO2, the Zen detection concentration is less than 2ppm.

6. Power Conditions: 220V ±10%, 50 ± 0.5 Hz

7. Power: approximately 2 kW



Key Features:

Key Performance Features:

Microcomputer control, keyboard settings, LCD display, with random memory function.

2. The signal from the detector, the values from the heater, the furnace temperature, the flow sensor readings, or the stored column compensation baseline signal can all be assigned to a simulated output channel.

3. Self-check and fault diagnosis, power-off protected stored experimental data, stopwatch and running timer, keyboard lock function.

4. The hydrogen flame ionization detector is easy to disassemble and install, facilitating cleaning or nozzle replacement with simple operation; the input signal can be logarithmically amplified, reducing interference, with high sensitivity, good linearity, and wide measurement range. Compatible with the U.S. HP-5890 gas chromatograph's micro thermal conductivity detector.

Achieve integration.

5. High-performance detectors and converters, with detection capabilities meeting the requirements of the Ministry of Power for determining gas composition content in transformer oil and environmental protection monitoring for trace CO and CO2 detection.

6. Utilizes a dual分流column system for fast analysis and excellent reproducibility.

7. Dual hydrogen flame design for separate detection of low hydrocarbon content and high CO, CO2 levels, eliminating interference between them, and enhancing detection sensitivity.

8. Compatible with our company's manufactured headspace sampler, which reduces sample contamination.

9. Utilizing new column packing and a dual-column temperature process, the detection time for C2H2 is advanced, sensitivity is enhanced, and the analysis cycle is shortened.

10. Analyte Composition: TCD: H2, O2

FID I:CH4,C2H2。C2H4,C2H6

FID II:CO,CH4,CO2