Supply BJC pH Electrode S400-RT330-M10FF S400 pH Probe

USA BJC S400-RT330-A10FF electrode standard with 3-meter cable Common models are as follows: | ||
S400-RT330-A10FF | Standard 3/4 inch thread | |
S400-RT330-M10FF | Standard with thick cable | |
S400-RT33D-E10FF | Pt100 Temperature Compensation | |
S400-RT33H-E10FF | Pt1000 temperature compensation | |
S400-RT33D-E30FF | Pt100 temperature compensation and cable with a length of nearly 10 meters | |
USA BJC S400-RT330-A10FF electrode standard configuration with 3-meter cable technical specifications:
pH Range: 0 - 14 pH Temperature Range: 0 - 105℃ Pressure Rating: 150 psig at 100°C Reference Electrode: Ag/AgCl Fluid Connector Material: Ryton?, Teflon?, Glass Standard Cable Length: 10 ft Low Noise Cable | ||
USA BJC S400-RT330-A10FF electrode standard with 3-meter cable Application Scenario:Online Water and Wastewater Testing Installation Method:Immersion and pipeline installation Electrode Flow Rate:3 meters per second Output Impedance:<250 MΩ at 25℃ Liquid connection material:Ryton, Teflon, glass Reference Diaphragm:Coaxial annular Teflon diaphragm, highly resistant to contamination, with a large surface area, featuring a two-stage design, significantly enhancing the reference electrode's anti-interference capability. US BJC S400-RT330-A10FF S400 electrode standard configuration with 3-meter cable option: | ||
S4 | 1 | 2 | - | 3 | 4 | 5 | 6 | 7 | - | 8 | 9 | 10 |
Location | Description | |||||||||||
1-2 | Appearance and construction | |||||||||||
00 Standard plug-in type, with glass head protective baffle, 3/4" NPT threads, flat head or concave diaphragm not available | ||||||||||||
3 | Electrode body material | |||||||||||
R Ryton | ||||||||||||
G Grounding Ryton | ||||||||||||
4 | Fluid Sealing Diaphragm Type | |||||||||||
T Coaxial Teflon Diaphragm | ||||||||||||
5-6 | Glass Sensing Head | |||||||||||
33 pH, HT-3 Film, Hemispherical | ||||||||||||
43 pH, HT-4 film, spherical, suitable for testing pH>13 and resistance to HF corrosion | ||||||||||||
7 | Temperature probe | |||||||||||
0 Without Temperature Probe | ||||||||||||
1 3KΩ | ||||||||||||
D Pt 100 | ||||||||||||
H Pt 1000 | ||||||||||||
8 | Cable Type | |||||||||||
A 3 mm low-noise coaxial cable, no temperature signal | ||||||||||||
5mm Low Noise Coaxial Cable, No Temperature Signal | ||||||||||||
Temperature Signal-Containing Shielded Cable | ||||||||||||
N *** Shielded Cable, with Temperature Signal and Ground Wire | ||||||||||||
9-10 | Cable Length | |||||||||||
10 x 10 feet | ||||||||||||
XX over 10 feet, please specify | ||||||||||||
11-12 | Cable Connector | |||||||||||
BC BNC (for ORP electrode) | ||||||||||||
FB BNC and Soldering Tip | ||||||||||||
FF Soldering Tip | ||||||||||||
For example, the S400 electrode model is S400-RT330-A10FF, indicating standard configuration with a 10-foot thin cable.