ZK-07 Network Line Interference Generator - Gigabit 24-Port Ethernet Line Interference Generator_供应产品_Jiangxi NetSafe Information Technology Co., Ltd. 
在线客服 在线客服邀请中...
关闭

您好,现在客服正邀请与您通话,请留下您的联系方式,客服将尽快与您取得联系。

 点击提交代表您同意《服务条款》《隐私政策》
Jiangxi NetSafe Information Technology Co., Ltd.

Red & Black Isolation Outlets, Microcomputer Video Information Protection, Pa...

13970081960

ZK-07 Network Line Interference Generator - Gigabit 24-Port Ethernet Line Interference Generator

产品Price 13400.00/Tai

最小起订Quantity:1 Tai 供货总Quantity: 10000 Tai

用手机扫描二维码直达商品手机版
MobileView details
Location:
Jiangxi/Nanchang
有效期至:
长期有效
最后更新:
2023-06-05 18:07

Recommended Products

猜你喜欢

Product Details

Network Line Interference Generator Zhong'an Xingkun zk-07 Gigabit 24-Port Ethernet Line Interference Generator





For office buildings that do not meet the standard, installation of the line interference device does not require breaking walls or slots, causing no damage to the interior and exterior decorations, and does not affect the use of PCs. There is no need to move office equipment. Simply connect the PC's network card output to the electrical port of the interference device, and the other electrical port of the interference device is connected with the original RJ-45 connector to complete the installation.
Installation and Configuration Method for Line Conduction Interference: The line conduction interference should be installed according to the illustrated method, simple and convenient.

Test Conclusion
The electromagnetic interference signal emitted by the tested jammer can overwhelm the leakage information on unshielded twisted pair cables within the frequency range of 1MHz to 1GHz.
② The electromagnetic interference signal emitted by the tested jammer does not affect the normal transmission of data during both low-speed and high-speed data transmission over the network.
  No defects.
Our company employs various testing technologies to assess the transmission of image files, data files, and potential error codes that may arise during the operation of line interference suppressors. The results are as follows:
① Low error rate: tested 4 billion bits, no errors.
② High-speed: Measures 8 billion bits, error-free.

Frequency Range
Interference transmission frequencies from 1MHz to 1GHz, effectively protecting confidential information. Green and environmentally friendly.
Utilizing unique conduction interference technology, interference signals are transmitted only within the network cable, emitting only minute amounts of electromagnetic waves into space, thus posing no harm to the human body.
Low interference power
Utilizes unique shielding technology, thus eliminating the need for high-power interference sources to cover up signal leaks on the network cable.
Easy installation and use
Standard cabinet design, easy installation, simple interfaces, user-friendly.

 

Technical Specifications

 

 

.Interference Frequency Range: IMHz - IGHz
.Interference Strength: > 3dB above normal transmission signal
Operating Temperature: 10°C to 35°C
Operating Humidity: HR < 75%
Working Voltage: 220V ±5%
Continuous Operating Time > 20,000 hours


询价单
主题 *
内容 *
Your company's名
Contact person *
ContactPhone *
电子Email
验证码  
 点击确定代表您同意《服务条款》《隐私政策》
 
 Click submit means you agree to《Service terms》《Privacy policy》

Phone Consultation

Consultation Phone:
13970081960

Back to Top