- AllProduct Category
-
Control Cabinet Division
Cable & Wire Division
Pressure Gauge Division
Digital Gauge Division
Validation Instrument Division
Level Measurement Division
Temperature Instrument Division
Transmitter Division
Flow Meter Division


详情描述
Industrial Explosion-Proof Platinum Resistance Products Features:
An industrial explosion-proof platinum resistance thermometer is a type of temperature sensor. It is widely used in industrial automatic control systems. Through the temperature sensor, the temperature parameters of the control object can be converted into electrical signals, transmitted to display, recording, and regulating instruments, and the system can be monitored, adjusted, and controlled. In chemical factories and production sites, various flammable and explosive gases and vapors are often present. Using ordinary platinum resistances is extremely unsafe and can easily cause environmental gas explosions. Therefore, in such situations, explosion-proof thermocouples must be used as temperature sensors. Our factory's explosion-proof platinum resistance products are suitable for use in areas with explosive gas hazards within the temperature class range of d ii bt4 to d ii ct6. The explosion-proof thermocouples produced by our factory use imported components as the sensing elements, and their technical performance meets the industrial platinum electrical technology conditions and scale in ZBY301-85. At the same time, the products comply with the general requirements for explosion-proof electrical equipment used in explosive environments, as specified in GB3836.1-83 and GB3836.2-83 standards.
◆ Industrial Explosion-Proof Platinum Resistance ThermometerKey Technical Specifications
Range Specifications
Model | Pitch number | Temperature Range: °C | Precision Grade | Allowable deviation △t ℃ |
| wzp wzp 2 wzpk wzpk 2 | pt100 | -200~500 | Grade A | ±(0.15+0.002|t|) |
| B Grade | ±(0.30+0.005|t|) |
Note: "t" represents the absolute value of the actual temperature of the thermosensitive element; only the b-grade platinum resistance thermometers are supplied.
Resistance thermometers allow current to pass through.
The measured current through the platinum resistance shall not exceed 5mA.
Explosion-proof types and groups
Intrinsically Safe Groups: d II BT4 or d II CT4; d II BT6 or d II CT6
Shell Protection Grade: IP54
Principle Structure
Explosion-proof thermistors and assembled thermistors have similar structures and principles. The main difference lies in the junction box (housing) of the explosion-proof products.
The design incorporates a special explosion-proof structure, with the junction box made of high-strength aluminum alloy die casting, featuring ample internal space and walls.
Thickness and mechanical strength, as well as the thermal stability of the rubber sealing rings, comply with national explosion-proof standards. Therefore, when explosive mixtures are inside the junction box,
When the body explodes, the internal pressure will not damage the junction box, and the resulting heat energy cannot propagate outward—detonate.
Due to the product's adoption of the aforementioned explosion-proof special structure, it fully complies with use in explosion-proof temperature ratings from d ii bt4 to d ii ct6.
Within the specified group range, the product can achieve a reliable explosion-proof effect as long as the user strictly adheres to the product usage rules.
Description of categories, levels, and temperature classes for electrical equipment:
Electrical equipment is divided into two categories: i) Equipment for use in coal mine underground.
ii Class - Industrial Electrical Equipment
Intrinsically Safe Rating
Explosion-proof thermal resistorThe explosion-proof grade is rigid, and it applies to the maximum safe gap for explosive gas mixtures, which is divided into three levels: a, b, and c.
Temperature Category
Explosion-proof tropical inner resistance is divided into six groups (t1~t6) according to the highest surface temperature of its exposed part.
Types and specifications
| Category | Model | Pitch number | Temperature Range: °C | Protective Pipe Material | Thermal response time t0.5s | Nominal Pressure MPa | Structure Features | Specs | Explosion-proof Level | |
| Overall Length l (mm) | Insertion Depth l (mm) | |||||||||
| Platinum Resistance Thermometer | wzp-24sa | pt100 | -200~500 | 1Cr18Ni9Ti stainless steel or 0Cr18Ni12Mo2Ti | ≤ 90 | 10 | Explosion-proof terminal box with M27*2 fixing thread, fixed flange installation | 250 350 400 450 550 650 900 1150 | 100 200 250 300 400 500 750 1000 | d iibt4 d ii bt6 or d ii ct4d ii ct6 |
wzp2-24sa | ||||||||||
wzp-44sa | 6.4 | |||||||||
wzp2-44sa | ||||||||||
wzp -64s wzp2 | 1cr18ni9ti | 30 | Conical protective tube M33*2 | 250 350 450 | 100 200 300 | |||||
Types and Specifications
| Category | Model | Fractional pitch | Temperature Range: ℃ | Pipe Diameter d (mm) | Hot response time t0.5s | Nominal Pressure mpa | Structure Features | Specs | Ex-proof rating | |
| Overall Length l (mm) | Insertion Depth (mm) | |||||||||
| Platinum Resistance Thermometer | wzpk-24 wzpk2-24 | pt100 | -200-500 | φ 6 or φ 5 | ≤ 12 ≤ 8 | 10 | Explosion-proof junction box with M27*2 fixed thread installation | 300 350 450 550 650 900 1150 | 150 200 300 400 500 750 1000 | d iibt4 d iibt6 or d iict4 d iict6 |
| wzpk-44wzpk2-44 | 6.4 | Explosion-proof junction box fixed flange installation | ||||||||
询价单