Our GYZRHM electric high-pressure regulating valve is composed of a PSL series or 3810L series direct-acting electric actuator and a high-pressure regulating valve body. The electric high-pressure cage-type regulating valve is a product developed to address the serious issues of short lifespan, valve stem breakage, and sleeve detachment in regulating valves under severe conditions of high pressure or pressure difference, severe cavitation, and erosion. By using a cage-type throttle design to distribute pressure differences, it reduces cavitation, erosion, and turbulent damage, significantly extending the lifespan of the regulating valve, especially in urea systems where it can increase lifespan by 2-3 times compared to standard high-pressure valves. The electric actuator features an integrated structure with a servo amplifier, input control signals (4-20mADC or 1-5VDC), and power supply to control the valve opening, achieving regulation of pressure, flow rate, level, temperature, and other process parameters. The valve body is a straight-through design with a single-directional valve core, featuring a simple flow path and low resistance, making the electric high-pressure regulating valve particularly suitable for regulating fluids with high viscosity, suspended solids, and particulate matter, which can prevent coking, adhesion, and blockage. The electric high-pressure regulating valve is characterized by its sensitive operation, simple wiring, large flow rate, compact size, and high regulation accuracy.
Electrical High-Pressure Regulating Valve Technical Specifications
| Nominal Diameter (DN) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Valve Seat Diameter (DN) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
| Rated Flow Coefficient (KV) | Single Seat | 6.9 | 11 | 17.6 | 27.5 | 44 | 69 | 110 | 176 | 275 | 440 | 630 | 875 | 1250 |
| Cage-type | 6.3 | 10 | 16 | 25 | 40 | 63 | 100 | 155 | 250 | 370 | 580 | 900 | 1300 | |
| Allowable Pressure Difference (MPa) | Nominal Pressure ≤ | |||||||||||||
| Nominal Pressure (MPa) | 10.0、16.0、25.0、32.0、45.0 | |||||||||||||
| Rated Stroke (mm) | 16 | 25 | 40 | 60 | 100 | |||||||||
| Valve cover style | Standard Type (-17~+250℃), High Temperature Type (+250~+450℃) | |||||||||||||
| Cap Style | Bolt-tensioned | |||||||||||||
| Sealed packing material | V-shaped polytetrafluoroethylene packing, V-shaped flexible graphite packing | |||||||||||||
| Valve core type | Single-seated, cage-type | |||||||||||||
| Flow Characteristics | Please wait for the percentage. | |||||||||||||
| Configuration Actuator Type | 3810 series, PSL series, and other electric actuators (customer-specified brands available) | |||||||||||||
| Actuator Parameters | Power Voltage: 220V, Input Signal: 4-20mA or 1-5V·DC, Output Signal: 4-20mA·DC | |||||||||||||
| Protection Level: Equivalent to IP65, Explosion-Proof Mark: ExdⅡBT4 (ExdⅡBT6 available for special customization), Manual Operation Function: Handle | ||||||||||||||
| Ambient Temperature: -25~+70℃, Relative Humidity: ≤95% | ||||||||||||||
Electrical High-Pressure Regulating Valve - Performance Specifications
| Project | Index value | ||
|---|---|---|---|
| Basic Error % | 3810L ±2.5; PSL ±1.0 | ||
| Difference Return % | 381L ±2.0; PSL ±1.0 | ||
| Dead Zone % | 1.0 | ||
| Always Point Deviation % | Electro-Open | Starting ±2.5 | End ±2.5 |
| Origin ±2.5 | End ±2.5 | ||
| Electric Shutoff | Origin | ±2.5 | |
| End Point | ±2.5 | ||
| Rated Stroke Deviation % | ≤2.5 | ||
| Leakage Rate L/h | 0.01% of rated capacity | ||
| Adjustable Range: R | 30:1 | ||
Electric High-Pressure Regulating Valve, Parts Material
| Valve body | Forged Steel (A105, 304, 316, 316L) |
|---|---|
| Gasket | PTFE, metal graphite gaskets, metal V-seal gaskets |
| Valve seat | 304, 316, 316L, Special |
| Valve core assembly | 304, 316, 316L, Special |
| Filling Material | PTFE, PPL, flexible graphite |
| Filling Cap | WCB, CF8, CF8M, CF3, CF3M, 2520, 2507, Hastelloy, Titanium Alloys |
Electrical High-Pressure Regulating Valve - Connection Dimension Drawing
![]() | ![]() |
|---|---|
| GYZRHP Electric High-Pressure Regulating Valve (Welded Body) | GYZRHP Electric High-Pressure Regulating Valve (Flanged Body) |
Electrical High-Pressure Regulating Valve - Connection Size
| Nominal Pipe Size (NPS) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L | National Standard | National Standard Pressure: PN10.0, 16.0, 25.0, 32.0, 45.0 MPa ASME Pressure: 150LB, 300LB, 600LB, 900LB, 1500LB, 2500LB | ||||||||||
| ANSI Standard | ||||||||||||
| H、H1、H2 | H, H1: The size is as designed by the engineer H2, D: The size is determined by the torque of the regulating valve. | |||||||||||
| R | ||||||||||||
Electrical High-Pressure Regulating Valve Product Selection
(1) Valve Body Parameters: Nominal Diameter, Working Pressure, Process Medium, Application, Valve Body Material, and other series parameters.
(2) Actuator Parameters: Actuator Type, Control Method, Control Signal (4-20mA, 1-5V), Operating Mode (Air-Open, Air-Closed)
Please provide as much detail as possible regarding the above technical specifications to facilitate our production and technical team in accurately selecting the right products for you. Should you have any questions, feel free to call us, and we will be dedicated to providing you with excellent service!