详细Info

Hotels are a familiar sight, and it's common for them to opt for central air conditioning. Given the unique usage of hotel central air conditioning systems, which are typically operational year-round, their maintenance and cleaning require special attention.

Central Air Conditioning Cleaning Method for Continuous Hotels in Summer

Hotel central air conditioning cleaning is mainly divided into three parts: the cooling water system, the chilled water system, and the surface of the heat exchangers. These three parts have different conditions and environments, as well as varying corrosion ranges, so the cleaning process differs accordingly. "Non-stop cleaning" refers to the refrigeration compressor remaining in the on state during the cleaning fluid circulation process, with the cleaning fluid circulating as cooling water or chilled water within the air conditioning system. It is particularly noteworthy that when the cleaning fluid circulates as chilled water, it not only flows through the internal pipes of the system but also through the external distribution tanks, which will affect both refrigeration and insulation, as well as cooling and insulation. The AD of the compressor will increase. The pump for cleaning the hotel central air conditioning without interruption is installed within the air conditioning system. The external water tanks and pipes should be connected in advance. Then, when the night temperatures are lower and passengers are in a state of sleep, the internal and external pipes of the system will be connected (and disconnected) using a shorter shutdown time. Use of central air conditioning.