Product Technical Specifications
1. Electrical specifications
(1) Standard power of constant power electric heating tape: 40w/m
(2) Rated Voltage: 220V
(3) Maximum heating length: 100-130m
(4) Temperature Controller Must Be Provided
(5) Equipped with a leakage protection device
2. Thermal performance specifications
At -10°C ambient temperature and 10 m/s wind speed, the internal temperature of the pipe can be maintained between 40-160°C.
(2) Sampling tubes are resistant to corrosion from various acidic and alkaline mediums, with a pressure resistance of 0.6 Mpa and no leakage.
(3) Sampling tubes can operate continuously at temperatures up to <250 degrees Celsius.
3. Installation Specifications
(1) Composite pipe minimum bend radius: 0.5m
(2) Maximum continuous length: 100-130m
(3) Limited fixed distance: 5m vertically, 2m horizontally
Note: Do not twist or drag on the ground during installation; the pipe end sleeve is only to be removed during the installation of the connection point.