详情描述

Standard Set Diesel Generator Recovery
Standard units are widely used in general installation locations within data centers. The unit primarily consists of diesel engines, generators, control systems, bases, vibration reduction devices, cooling systems, fuel supply systems, and output protection switches.
Protective-type Generator Set Diesel Engine Recovery
Protective type units are suitable for outdoor locations where noise is not a concern. They are primarily composed of standard units, protective casings, exhaust systems, etc. As the protective casings do not incorporate noise reduction devices, they only need to meet ventilation and protection against rain and snow, resulting in a smaller size and lower cost. Ventilation is achieved by opening doors and windows during operation. Protective power stations can be used individually or in parallel. Parallel usage is particularly suitable for scenarios with significant load variations, high reliability requirements for continuous operation, and cost-effective use, such as配套 oil field drilling rigs.
Noise-reduction type unit diesel generator recovery
Soundproofing units are widely used in outdoor and indoor environments that require noise protection and environmental protection, mainly composed of standard units, soundproof enclosures, intake and exhaust noise reduction devices, and exhaust noise reduction devices. Their main features include soundproof enclosures with sound-insulating and sound-absorbing layers, noise reduction treatment for intake and exhaust channels, and a combination of industrial and residential exhaust designs to reduce noise in both high and low frequency ranges. Standard soundproof units typically emit noise between 78-85dB(A), while soundproof units usually emit noise between 70-78dB(A). Soundproof units are developed based on standard soundproof units with more stringent noise control measures, such as labyrinth-type intake and exhaust channel designs, to achieve reduced noise emissions.
Noise-suppressing units generally have larger external dimensions and are more costly to manufacture than standard noise-suppressing units. Operation, maintenance, and repairs for noise-suppressing units are typically performed outside the soundproof enclosures.
Open-Air Power Station Diesel Generator Recovery
Low-noise containerized power stations and mobile containerized power stations are commonly used in outdoor environments where environmental protection is a priority. They can be directly placed outdoors for use, eliminating the need for a dedicated machine room. They also feature high mobility and a short time to commissioning. The noise level of these power stations is typically between 75-85 dB(A), allowing for operations, maintenance, and repairs to be carried out inside the containers.
Trailer-mounted Diesel Generator Recovery
The trailer power stations are available in two types: two-axle trailers and four-axle trailers. Units under 70KW use two-axle trailers, while 70KW to 500KW units utilize four-axle trailers. The trailer power station consists of standard trailers and noise-reduction generators, offering all the performance and advantages of noise-reduction generators, suitable for field operations and mobile power supply. The trailers are equipped with steering mechanisms, traffic warning lights, and braking systems, along with mechanical legs, shock absorbers, and buffers. The towing devices are adjustable in height, meeting traffic driving requirements. The trailer power stations can be pre-installed with cable racks and power cables for quick power supply. On urban roads and highways of level two and above, the two-axle trailers can travel at speeds up to 30km/h, and the four-axle trailers can reach speeds of up to 50km/h.
Portable Generator Diesel Generator for Vehicle-mounted Recovery
Vehicle-mounted power stations are widely used in communication, television broadcasting, expressways, emergency rescue, power supply, and other scenarios that require fast, mobile, and reliable power supply. The units are mainly installed in the body of a vehicle and can be equipped with electric cable winches, multi-way outlet sockets, and mechanical (or hydraulic) legs, allowing for easy parallel operation of multiple vehicle-mounted mobile power stations. The noise level of vehicle-mounted mobile power stations is generally between 70 to 80 dB(A).
Fuel-efficient diesel generator recycling
Protecting the fuel injection leading angle, taking the commonly used 195-type diesel engine as an example, its fuel injection timing angle is between 16 degrees and 20 degrees. After the diesel engine has been in use for a period, due to wear, the fuel injection timing angle will decrease, leading to late fuel injection timing and a significant increase in fuel consumption. Therefore, it is crucial to maintain the fuel injection angle at the proper angle.
Guarantee that the machine does not leak oil. The diesel engine's fuel line often has leaks due to uneven joint surfaces, deformed or damaged gaskets. The solution is: coat the gasket with valve paint, grind it flat on a glass plate to align the fuel line joints; install a diesel recovery device, which can connect the return oil tube from the nozzle to the hollow screw using a plastic tube, allowing the return oil to flow back into the fuel tank.