Low-voltage line protector

Low-voltage circuit protector

Intelligent low-voltage line protection devices are suitable for systems with rated voltages up to AC 660V (default 380V), rated currents up to AC 800A, and rated frequencies of 50/60Hz. They provide comprehensive intelligent protection for feed line terminals. They protect against faults such as short circuits, overcurrents, zero-sequence overcurrents, low voltage, and overvoltage during feed line operation. The protective device adopts a modular product structure, including the main unit (protection, measurement, and control function module), transformer modules, featuring complete electric quantity measurement functions. It also offers switch input monitoring, fault recording, analog signal transmission, and communication functions, allowing for easy connection to factory DCS systems for automated control. Control and protection for loads above 800A can be achieved through a 5A dedicated transformer.

Product Features

Auxiliary Power Supply: AC/DC 85~270V

Measurement Functions (Current, Voltage, Power, Energy, Zero Sequence/Leakage Current)

A comprehensive protection function featuring rapid, time-limited rapid, inverse-time overcurrent, time-limited overcurrent, unbalance, zero-sequence protection, overvoltage, undervoltage phase I, undervoltage phase II, and PT open-circuit protection, etc.

8-way DI passive dry node input; utilizes an internal DC15V power supply for signal and power.

4-way DO output for circuit breaker protection, remote control, and alarm.

Standard RS-485 communication interface with Modbus-RTU protocol ensures fast and reliable communication with the host computer.

Features a DC4-20mA analog output interface, directly connectable to DCS systems, enabling on-site equipment monitoring.

Equipped with a system clock and 50 event logging capabilities, the system clock records the current time (year, month, day, hour, minute, second, millisecond); the fault logging function records the time and cause of system malfunctions.

The display is equipped with a Chinese dot matrix LCD screen, offering a user-friendly interface.

Can replace various conventional components such as voltmeters, signal lights, thermal relays, and current transmitters, reducing the amount of cable connections inside the cabinet and on-site construction. It offers higher reliability and overall cost-effectiveness compared to traditional solutions.

With integrated multiple protection features, the low-voltage line protector can quickly respond to various fault conditions, cut off the faulty circuit, prevent the fault from spreading and expanding, ensuring the stable operation of the electrical system.

Feature Configuration

Type and FunctionFeature Configuration
Standard FeaturesEnhanced features
Protective FunctionInstant decision
Speed limit cutoff
Inverse-time overcurrent
Time-delayed overcurrent protection
Unbalanced Protection
Residual Current (Select one only)Zero Sequence (Self-produced)
Zero Sequence (Transformer Connection)
√ (Zero Sequence)
Leakage (Transformer Connection)
√ (Leakage)
Under-voltage, over-voltage
PT Disconnection
Anti-surge module
Communication FeaturesRS485 Interface Communication Protocol: MODBUS-RTU
Switched quantity input8-way DI
Relay Output4-way DO
Analog OutputDC 4-20mA throughout
√ (Analog Function)
Fault Record50 event records, documenting the type and time of motor failures
Measurement showsMeasurement ParametersCurrent, Voltage, Power, Power Factor
Zero-sequence current, electrical energy, frequency
Setpoint valueSetpoint configurationVarious protection setpoint inquiries
Various protection setpoints


Technical Specifications

Technical SpecificationsKey Technical Specifications
Working Power SupplyAC/DC 85~265V, Power Consumption 8VA
Rated Working VoltageAC 380V / 660V (non-standard, specify upon order), 50Hz / 60Hz
Rated Operating CurrentUtilize an external dedicated current transformer that matches the rated current.
Relay Output Contact RatingResistive LoadAC220V、5A;DC24V、6A;
感性负载 Inductive LoadAC220V、2A;DC24V、2A;
Switched quantity inputDry Node (Built-in DC15V)
CommunicationRS485 Modbus-RTU Protocol
EnvironmentalOperating Temperature-20ºC~+55ºC
Storage Temperature-25ºC~+70ºC
Relative Humidity≤95% no condensation, non-corrosive gases
Altitude≤2000m
Pollution Level2nd Grade
Protection GradeIP45 (mounted on cabinet panel)
Installation CategoryIII Grade


Dimensions and wiring diagram


Instrument appearanceHousing dimensionsHole Size
72 SquareABCDE
737369.56767

Installation size diagram (in mm)

Backside terminal diagram





在线咨询
Hotline:17306773009
  • Product Introduction
  • Technical Parameters
  • Custom Selection

Low-voltage circuit protector

Intelligent low-voltage line protection devices are suitable for systems with rated voltages up to AC 660V (default 380V), rated currents up to AC 800A, and rated frequencies of 50/60Hz. They provide comprehensive intelligent protection for feed line terminals. They protect against faults such as short circuits, overcurrents, zero-sequence overcurrents, low voltage, and overvoltage during feed line operation. The protective device adopts a modular product structure, including the main unit (protection, measurement, and control function module), transformer modules, featuring complete electric quantity measurement functions. It also offers switch input monitoring, fault recording, analog signal transmission, and communication functions, allowing for easy connection to factory DCS systems for automated control. Control and protection for loads above 800A can be achieved through a 5A dedicated transformer.

Product Features

Auxiliary Power Supply: AC/DC 85~270V

Measurement Functions (Current, Voltage, Power, Energy, Zero Sequence/Leakage Current)

A comprehensive protection function featuring rapid, time-limited rapid, inverse-time overcurrent, time-limited overcurrent, unbalance, zero-sequence protection, overvoltage, undervoltage phase I, undervoltage phase II, and PT open-circuit protection, etc.

8-way DI passive dry node input; utilizes an internal DC15V power supply for signal and power.

4-way DO output for circuit breaker protection, remote control, and alarm.

Standard RS-485 communication interface with Modbus-RTU protocol ensures fast and reliable communication with the host computer.

Features a DC4-20mA analog output interface, directly connectable to DCS systems, enabling on-site equipment monitoring.

Equipped with a system clock and 50 event logging capabilities, the system clock records the current time (year, month, day, hour, minute, second, millisecond); the fault logging function records the time and cause of system malfunctions.

The display is equipped with a Chinese dot matrix LCD screen, offering a user-friendly interface.

Can replace various conventional components such as voltmeters, signal lights, thermal relays, and current transmitters, reducing the amount of cable connections inside the cabinet and on-site construction. It offers higher reliability and overall cost-effectiveness compared to traditional solutions.

With integrated multiple protection features, the low-voltage line protector can quickly respond to various fault conditions, cut off the faulty circuit, prevent the fault from spreading and expanding, ensuring the stable operation of the electrical system.

Feature Configuration

Type and FunctionFeature Configuration
Standard FeaturesEnhanced features
Protective FunctionInstant decision
Speed limit cutoff
Inverse-time overcurrent
Time-delayed overcurrent protection
Unbalanced Protection
Residual Current (Select one only)Zero Sequence (Self-produced)
Zero Sequence (Transformer Connection)
√ (Zero Sequence)
Leakage (Transformer Connection)
√ (Leakage)
Under-voltage, over-voltage
PT Disconnection
Anti-surge module
Communication FeaturesRS485 Interface Communication Protocol: MODBUS-RTU
Switched quantity input8-way DI
Relay Output4-way DO
Analog OutputDC 4-20mA throughout
√ (Analog Function)
Fault Record50 event records, documenting the type and time of motor failures
Measurement showsMeasurement ParametersCurrent, Voltage, Power, Power Factor
Zero-sequence current, electrical energy, frequency
Setpoint valueSetpoint configurationVarious protection setpoint inquiries
Various protection setpoints


Technical Specifications

Technical SpecificationsKey Technical Specifications
Working Power SupplyAC/DC 85~265V, Power Consumption 8VA
Rated Working VoltageAC 380V / 660V (non-standard, specify upon order), 50Hz / 60Hz
Rated Operating CurrentUtilize an external dedicated current transformer that matches the rated current.
Relay Output Contact RatingResistive LoadAC220V、5A;DC24V、6A;
感性负载 Inductive LoadAC220V、2A;DC24V、2A;
Switched quantity inputDry Node (Built-in DC15V)
CommunicationRS485 Modbus-RTU Protocol
EnvironmentalOperating Temperature-20ºC~+55ºC
Storage Temperature-25ºC~+70ºC
Relative Humidity≤95% no condensation, non-corrosive gases
Altitude≤2000m
Pollution Level2nd Grade
Protection GradeIP45 (mounted on cabinet panel)
Installation CategoryIII Grade


Dimensions and wiring diagram


Instrument appearanceHousing dimensionsHole Size
72 SquareABCDE
737369.56767

Installation size diagram (in mm)

Backside terminal diagram





品牌: Yongnuo Electrical
Brand: Yongnuo Electrical
Region: National
Model: Customizable