Arc Fault Circuit Interrupter

The AFDD-63 ArcFault Circuit Breaker (AFCI, also known as AFDD ArcFault Detector) technology is a circuit protection product. Its primary function is to detect and differentiate dangerous ground arc faults, parallel arc faults, and series arc faults, and promptly activate the device to interrupt the current to prevent electrical fires. In the event of an arc fault, due to the relatively low current strength, which is below the set values of overcurrent protection widely installed in the power system, especially in the low-voltage distribution field, installing an AFCI fault arc circuit breaker at the distribution line terminal can promptly detect and cut off the circuit, effectively reducing the losses caused by the arc.

Product Features

If "spark" or arc occurs in the circuit, immediately disconnect the power supply to effectively reduce losses.

Support custom-made residual current protection

Left zero, right fire; left fire, right zero; or double break point - three types of break point methods

Track installation, enhance work efficiency

Utilizing fire-retardant materials to enhance system safety.

Protective Functions


Capable of promptly cutting off the power supply to short-circuit, overloading, arc, and leakage faults in the load supply lines


Technical Specifications

PerformanceParameters
Meets standardsIEC/EN62606,IEC/EN61009,GB/T31143-2014,GB14048.2
Rated Operating VoltageAC230V/AC110V
Rated Frequency50Hz/60Hz
Rated Current (ln)6,10,16,20,25,32,40,50,63A
Extreme Number1P/2P
Rated Impulse Withstand Voltage Uimp4KV
Rated short-circuit breaking capacity4.5KA
Rated Disconnection Current In10mA to 50mA adjustable
Rated Non-Release Current Ino0.5ln
Detent Curve0.5ln
Action TypeInstant, Delayed, Selective
Leakage typeAC,A
Overvoltage adjustable range250-280V
Under-voltage adjustable range180-120V
Contact InformationRF2.4G CAN BUS
Basic Protection FeaturesCapable of promptly cutting off the power supply to short-circuit, overloading, arc, and leakage faults in the load supply lines
Additional features and specificationsEquipped with LED status indicator, fault memory, load (LED indicator when >2A), and leakage warning function. Capable of wireless networking and energy management.
Service LifeElectrical lifespan≥3,000 operating cycles
Mechanical lifespan≥10,000 operating cycles
Protection GradeIP20
Protection Grade (within the distribution box)IP40
Operating Temperature-20℃~+45℃
Store at transport temperature-35℃~+60℃
Termination Wire Capability1-25mm2


Application Scope

Fault Arc Protection Devices are suitable for electrical lines in industrial and residential buildings with power ratings of 10KW or less, with the protected line length not exceeding 100 meters. They are applicable to nursing homes, schools, commercial buildings, hotels, factories, warehouses, libraries, offices, and residential homes.


在线咨询
Hotline:17306773009
  • Product Introduction
  • Technical Parameters
  • Custom Selection

The AFDD-63 ArcFault Circuit Breaker (AFCI, also known as AFDD ArcFault Detector) technology is a circuit protection product. Its primary function is to detect and differentiate dangerous ground arc faults, parallel arc faults, and series arc faults, and promptly activate the device to interrupt the current to prevent electrical fires. In the event of an arc fault, due to the relatively low current strength, which is below the set values of overcurrent protection widely installed in the power system, especially in the low-voltage distribution field, installing an AFCI fault arc circuit breaker at the distribution line terminal can promptly detect and cut off the circuit, effectively reducing the losses caused by the arc.

Product Features

If "spark" or arc occurs in the circuit, immediately disconnect the power supply to effectively reduce losses.

Support custom-made residual current protection

Left zero, right fire; left fire, right zero; or double break point - three types of break point methods

Track installation, enhance work efficiency

Utilizing fire-retardant materials to enhance system safety.

Protective Functions


Capable of promptly cutting off the power supply to short-circuit, overloading, arc, and leakage faults in the load supply lines


Technical Specifications

PerformanceParameters
Meets standardsIEC/EN62606,IEC/EN61009,GB/T31143-2014,GB14048.2
Rated Operating VoltageAC230V/AC110V
Rated Frequency50Hz/60Hz
Rated Current (ln)6,10,16,20,25,32,40,50,63A
Extreme Number1P/2P
Rated Impulse Withstand Voltage Uimp4KV
Rated short-circuit breaking capacity4.5KA
Rated Disconnection Current In10mA to 50mA adjustable
Rated Non-Release Current Ino0.5ln
Detent Curve0.5ln
Action TypeInstant, Delayed, Selective
Leakage typeAC,A
Overvoltage adjustable range250-280V
Under-voltage adjustable range180-120V
Contact InformationRF2.4G CAN BUS
Basic Protection FeaturesCapable of promptly cutting off the power supply to short-circuit, overloading, arc, and leakage faults in the load supply lines
Additional features and specificationsEquipped with LED status indicator, fault memory, load (LED indicator when >2A), and leakage warning function. Capable of wireless networking and energy management.
Service LifeElectrical lifespan≥3,000 operating cycles
Mechanical lifespan≥10,000 operating cycles
Protection GradeIP20
Protection Grade (within the distribution box)IP40
Operating Temperature-20℃~+45℃
Store at transport temperature-35℃~+60℃
Termination Wire Capability1-25mm2


Application Scope

Fault Arc Protection Devices are suitable for electrical lines in industrial and residential buildings with power ratings of 10KW or less, with the protected line length not exceeding 100 meters. They are applicable to nursing homes, schools, commercial buildings, hotels, factories, warehouses, libraries, offices, and residential homes.


品牌: Yongnuo Electrical
Model: Customization supported
Region: National
Brand: Yongnuo Electrical
单价: 电议
最小起订Quantity:
供货总Quantity:
有效期至: 长期有效
最后更新: 2025-03-13 17:39

Core Custom Selection

24h Online Service

Submit your requirements for quick product recommendations

Service
Hotline
17306773009
 Click submit means you agree to《Service terms》《Privacy policy》